New type of filaments for improved accuracy of multiple sulfur isotope analyses by electron-impact gas-source mass spectrometry

被引:0
|
作者
Cartigny, Pierre [1 ]
Bouyon, Amaury [1 ,2 ,3 ]
Bars, Hartmut [4 ]
Albrecht, Nina [4 ]
Kohl, Issaku E. [4 ]
Landais, Guillaume [1 ]
Duverger, Arnaud [1 ]
Farquhar, James [2 ,3 ]
机构
[1] Univ Paris, Inst Phys Globe Paris, CNRS, F-75005 Paris, France
[2] Univ Maryland, Earth Syst Sci Interdisciplinary Ctr, College Pk, MD USA
[3] Univ Maryland, Dept Geol, College Pk, MD USA
[4] Thermo Fisher Sci, Bremen, Germany
关键词
SULFIDE MINERALS; S-33; FRACTIONATION; SEASONALITY; PRECISION; OXYGEN; LASER; SO2; SF6;
D O I
10.1002/rcm.9873
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Rationale: The analysis of the three sulfur stable isotope ratios (S-33/S-32, S-34/S-32, S-36/S-32) is routinely performed by gas-source isotope ratio mass spectrometry (IRMS) on the SF6 gaseous molecule, collecting SF5+ ions at m/z similar to 127, 128, 129 and 131. High precision and accuracy are commonly achieved owing to a lack of correction because fluorine has only one isotope and the inert nature of the SF6 molecule. The analysis of the S-36/S-32 ratio is, however, complicated by the low abundance of S-36 (similar to 0.015%) and the possible occurrence of trace amounts of fluorocarbon compounds leading to (C3F5+)-C-12 ions at m/z similar to 131, i.e. where (SF5+)-S-36 ions are collected. Methods: We used gas-source high-resolution IRMS to better characterize the nature of possible interferences, and we tested novel types of filaments in order to investigate their influence on possible interferences. Results: We confirm that the (C3F5+)-C-12 ion represents the main isobaric interference at m/z similar to 131. We also demonstrate that tungsten fluoride adducts are formed from the reaction of fluorine ions derived during fragmentation of the SF6 molecule with the hot tungsten filament. These reactions lead to the formation of e.g. WF5+, WF4+, WF3+ ions, including doubly charged ions. WF4++, in particular, leads to isobaric interference on m/z similar to 128, 129 and 131 from (WF4++)-W-180, (WF4++)-W-182 and (186) WF4++ ions, respectively. Because W-180 (0.12%) is at low abundance, its influence on delta S-33 measurements would remain negligible, but W-182 (26.5%) and W-186 (28.4%) lead to scale contraction for both delta S-34 and delta S-36. Conclusions: Rather than correcting for these interferences, or working at high mass resolution, we suggest avoiding W isobaric interferences by using other types of filaments, with initial reports on both pure Re filaments and Y2O3-coated W filaments.
引用
收藏
页数:9
相关论文
共 50 条
  • [22] NEW OBSERVATIONS ON FRAGMENTATION PROPERTIES OF PEPTIDES UNDER ELECTRON-IMPACT MASS-SPECTROMETRY
    DELL, A
    MORRIS, HR
    [J]. BIOCHEMICAL AND BIOPHYSICAL RESEARCH COMMUNICATIONS, 1974, 61 (04) : 1125 - 1132
  • [23] Determination of silicon isotopic composition in soil using gas-source isotope ratio mass spectrometry by thermal decomposition of barium hexafluorosilicate
    Zhang, Jiang-yi
    Zhang, Gui-ming
    Wang, Ya-Nan
    Liu, Wen-jing
    Xu, Zhi-fang
    [J]. MICROCHEMICAL JOURNAL, 2024, 203
  • [24] MEASUREMENT OF ISOTOPE RATIOS IN ORGANIC-COMPOUNDS AT PICOMOLE QUANTITIES BY CAPILLARY GAS-CHROMATOGRAPHY QUADRUPOLE ELECTRON-IMPACT MASS-SPECTROMETRY
    STELLAARD, F
    PAUMGARTNER, G
    [J]. BIOMEDICAL MASS SPECTROMETRY, 1985, 12 (09): : 560 - 564
  • [25] A VERY HIGH-YIELD ELECTRON-IMPACT ION-SOURCE FOR ANALYTICAL MASS-SPECTROMETRY
    KOONTZ, SL
    DENTON, MB
    [J]. INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1981, 37 (02): : 227 - 239
  • [26] A modified procedure for gas-source isotope ratio mass spectrometry: the long-integration dual-inlet (LIDI) methodology and implications for clumped isotope measurements
    Hu, Bin
    Radke, Jens
    Schlueter, Hans-Juergen
    Heine, Frank Torsten
    Zhou, Liping
    Bernasconi, Stefano M.
    [J]. RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2014, 28 (13) : 1413 - 1425
  • [27] DETERMINATION OF LSD IN URINE BY CAPILLARY COLUMN GAS-CHROMATOGRAPHY AND ELECTRON-IMPACT MASS-SPECTROMETRY
    FRANCOM, P
    ANDRENYAK, D
    LIM, HK
    BRIDGES, RR
    FOLTZ, RL
    JONES, RT
    [J]. JOURNAL OF ANALYTICAL TOXICOLOGY, 1988, 12 (01) : 1 - 8
  • [28] ANALYSIS OF TERBUTALINE IN BIOLOGICAL-FLUIDS BY GAS-CHROMATOGRAPHY ELECTRON-IMPACT MASS-SPECTROMETRY
    CLARE, RA
    DAVIES, DS
    BAILLIE, TA
    [J]. BIOMEDICAL MASS SPECTROMETRY, 1979, 6 (01): : 31 - 37
  • [29] MASS SPECTROMETRY .2. UNIMOLECULAR DECOMPOSITION OF BENZALDEHYDE AZINE IN GAS PHASE INDUCED BY ELECTRON-IMPACT
    SCHEPPEL.SE
    GRIGSBY, RD
    KINNEBER.KF
    MITCHELL, ED
    MANNAN, CA
    [J]. ORGANIC MASS SPECTROMETRY, 1970, 3 (05): : 557 - &
  • [30] MODEL FOR THE ESTIMATION OF ELECTRON-IMPACT GAS-CHROMATOGRAPHY MASS-SPECTROMETRY RESPONSE FACTORS FOR QUADRUPOLE MASS SPECTROMETERS
    SAUTER, AD
    DOWNS, JJ
    BUCHNER, JD
    RINGO, NT
    SHAW, DL
    DULAK, JG
    [J]. ANALYTICAL CHEMISTRY, 1986, 58 (08) : 1665 - 1670