The respective and dependent effects of scattering and bone matrix absorption on ultrasound attenuation in cortical bone

被引:1
|
作者
McCandless, Brett Austin [1 ]
Raum, Kay [2 ,3 ,4 ]
Muller, Marie [1 ]
机构
[1] North Carolina State Univ, Dept Mech & Aerosp Engn, Raleigh, NC 27695 USA
[2] Charite Univ Med Berlin, D-12203 Berlin, Germany
[3] Free Univ Berlin, D-12203 Berlin, Germany
[4] Humboldt Univ, Ctr Biomed, Ctr Regenerat Therapies, D-12203 Berlin, Germany
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2024年 / 69卷 / 11期
关键词
ultrasound; absorption; extinction length; bone characterization; scattering; MULTIPLE-SCATTERING; MINERAL DENSITY; NUMERICAL-SIMULATION; TRABECULAR BONE; PORE-SIZE; POROSITY; WOMEN; FRACTURE; RISK; TRANSPORT;
D O I
10.1088/1361-6560/ad3fff
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Cortical bone is characterized by a dense solid matrix permeated by fluid-filled pores. Ultrasound scattering has potential for the non-invasive evaluation of changes in bone porosity. However, there is an incomplete understanding of the impact of ultrasonic absorption in the solid matrix on ultrasound scattering. In this study, maps were derived from scanning acoustic microscopy images of human femur cross-sections. Finite-difference time domain ultrasound scatter simulations were conducted on these maps. Pore density, diameter distribution of the pores, and nominal absorption values in the solid and fluid matrices were controlled. Ultrasound pulses with a central frequency of 8.2 MHz were propagated, both in through-transmission and backscattering configurations. From these data, the scattering, bone matrix absorption, and attenuation extinction lengths were calculated. The results demonstrated that as absorption in the solid matrix was varied, the scattering, absorption, and attenuation extinction lengths were significantly impacted. It was shown that for lower values of absorption in the solid matrix (less than 2 dB mm-1), attenuation due to scattering dominates, whereas at higher values of absorption (more than 2 dB mm-1), attenuation due to absorption dominates. This will impact how ultrasound attenuation and scattering parameters can be used to extract quantitative information on bone microstructure.
引用
收藏
页数:13
相关论文
共 50 条
  • [31] Ultrasound velocity and cortical bone characteristics in vivo
    Sievänen, H
    Cheng, S
    Ollikainen, S
    Uusi-Rasi, K
    OSTEOPOROSIS INTERNATIONAL, 2001, 12 (05) : 399 - 405
  • [32] CORTICAL ULTRASOUND VELOCITY AS AN INDICATOR OF BONE STATUS
    STEGMAN, MR
    HEANEY, RP
    TRAVERSGUSTAFSON, D
    LEIST, J
    OSTEOPOROSIS INTERNATIONAL, 1995, 5 (05) : 349 - 353
  • [33] Differential effects of hormone replacement therapy on bone mineral density and axial transmission ultrasound measurements in cortical bone
    K. M. Knapp
    G. M. Blake
    T. D. Spector
    I. Fogelman
    Osteoporosis International, 2003, 14 : 289 - 294
  • [34] Differential effects of hormone replacement therapy on bone mineral density and axial transmission ultrasound measurements in cortical bone
    Knapp, KM
    Blake, GM
    Spector, TD
    Fogelman, I
    OSTEOPOROSIS INTERNATIONAL, 2003, 14 (04) : 289 - 294
  • [35] MEASUREMENT OF CORTICAL THICKNESS OF BONE BY PHOTON ABSORPTION
    MOORE, R
    WAHNER, HW
    PHYSICS IN MEDICINE AND BIOLOGY, 1972, 17 (03): : 446 - &
  • [36] Cohesive energy calculation for cortical bone matrix
    Tamilselvan, A
    Zhang, D
    PROCEEDINGS OF THE IEEE 28TH ANNUAL NORTHEAST BIOENGINEERING CONFERENCE, 2002, : 195 - 196
  • [37] Quantitative Ultrasound Assessment of Cortical Bone Properties Beyond Bone Mineral Density
    Grimal, Q.
    Laugier, P.
    IRBM, 2019, 40 (01) : 16 - 24
  • [38] ULTRASOUND SPEED IN EQUINE CORTICAL BONE - EFFECTS OF ORIENTATION, DENSITY, POROSITY AND TEMPERATURE
    MCCARTHY, RN
    JEFFCOTT, LB
    MCCARTNEY, RN
    JOURNAL OF BIOMECHANICS, 1990, 23 (11) : 1139 - 1143
  • [39] Effect of organic matrix alteration on strain rate dependent mechanical behaviour of cortical bone
    Uniyal, Piyush
    Sihota, Praveer
    Kumar, Navin
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2022, 125
  • [40] ON THE ATTENUATION AND VELOCITY DISPERSION OF ULTRASOUND THROUGH TRABECULAR BONE
    Deligianni, D.
    Koika, P.
    Asimakopoulou, T.
    Philippidis, T.
    ADVANCED TOPICS IN SCATTERING THEORY AND BIOMEDICAL ENGINEERING, 2010, : 305 - 312