Enhancing melting performance in multi-tube latent heat exchangers: Investigating the effect of inner tube number and arrangement

被引:1
|
作者
Kong, Benben [1 ]
Li, Yu [1 ]
Zou, Yitao [1 ]
Li, Yonghao [1 ]
Yang, Kaijie [1 ]
Shi, Hong [2 ]
Jiang, Yanlong [1 ]
机构
[1] Nanjing Univ Aeronaut & Astronaut, Key Lab Aircraft Environm Control & Life Support, MIIT, 29 Yudao St, Nanjing 210016, Peoples R China
[2] Jiangsu Univ Sci & Technol, Coll Energy & Power Engn, 2 Mengxi, Zhenjiang 212003, Peoples R China
关键词
Latent heat energy storage; Multi-tube heat exchanger; Arrangement; Phase change material (PCM); Melting process; Melting time; THERMAL-ENERGY STORAGE; PHASE-CHANGE MATERIALS; OPERATIONAL PARAMETERS; PCM; ENHANCEMENT;
D O I
10.1016/j.est.2024.112544
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The latent heat energy storage system holds promising application prospects in the field of energy. However, the critical bottleneck remains the melting speed of phase change materials (PCMs). In this study, the melting dynamics of PCM within a triplex-tube heat exchange system are investigated, focusing on the effects of varying the number and arrangement of inner tubes. The system performance with four, five, six, and seven inner tubes is compared, revealing a decrease in melting time with an increasing number of inner tubes. However, excessive numbers do not yield more significant enhancement. A novel arrangement scheme is proposed, recommending six inner tubes. Additionally, the effects of inner tube spacing, upper angle and lower angle are explored. Increasing these parameters initially decreases melting time but then exhibits a reverse trend. Specifically, appropriate spacing enhances coverage area, expediting rapid connectivity of melting areas and thereby augmenting natural convection. While an increase in the upper angle delays PCM melting in the upper half, optimal arrangement enhances lower half PCM melting. Balancing melting rates of three difficult-to-melt areas in the lower half with proper lower angle achieves optimal performance. Compared with the base case, the proposed arrangement with the tube spacing of 40 mm, upper angle of 92 degrees, and lower angle of 62 degrees reduces melting time by 44.8 %. These findings provide a theoretical and experimental foundation for enhancing PCM-based energy storage system performance, offering valuable insights for engineering applications.
引用
收藏
页数:15
相关论文
共 50 条
  • [31] Thermal performance evaluation of a latent heat thermal energy storage unit with an embedded multi-tube finned copper heat exchanger
    Mohamed, Fadl
    Eames, Philip C.
    [J]. EXPERIMENTAL HEAT TRANSFER, 2023, 36 (02) : 143 - 162
  • [32] Thermal performance modeling of turbulent flow in multi tube in tube helically coiled heat exchangers
    Fouda, A.
    Nada, S. A.
    Elattar, H. F.
    Refaey, H. A.
    Bin-Mahfouz, Abdullah S.
    [J]. INTERNATIONAL JOURNAL OF MECHANICAL SCIENCES, 2018, 135 : 621 - 638
  • [33] Effect of baffle spacing on pressure drop and local heat transfer in shell-and-tube heat exchangers for staggered tube arrangement
    Li, HD
    Kottke, V
    [J]. INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 1998, 41 (10) : 1303 - 1311
  • [34] Performance assessment of multi-tube He II/He II heat exchanger using a single tube sample
    Rousset, B.
    Millet, F.
    [J]. CRYOGENICS, 2022, 124
  • [35] Experimental investigations of high-temperature shell and multi-tube latent heat storage system
    Sodhi, Gurpreet Singh
    Vigneshwaran, K.
    Muthukumar, P.
    [J]. APPLIED THERMAL ENGINEERING, 2021, 198
  • [36] Influence of the inner tube rotation and translation associated movement on the charging performance for the latent heat thermal energy storage exchangers
    Shandong Engineering Research Center for High-efficiency Energy Storage and Hydrogen Energy Utilization, School of Energy and Power Engineering, Shandong University, Shandong, Jinan
    250061, China
    不详
    250061, China
    不详
    518057, China
    不详
    276800, China
    [J]. Renew. Energy,
  • [37] Thermal Performance Analysis of the Charging/Discharging Process of a Shell and Horizontally Oriented Multi-Tube Latent Heat Storage System
    Fadl, Mohamed
    Eames, Philip
    [J]. ENERGIES, 2020, 13 (23)
  • [38] Effect of Tube Arrangement on the Welding of the Tube-to-Tubesheet Joint of Shell-and-Tube Heat Exchangers Using the Finite Element Method
    Sheibani, Reza
    Rabiezadeh, Amin
    Jahedi, Reza
    Mohammadi, Mehrdad
    [J]. JOURNAL OF MATERIALS ENGINEERING AND PERFORMANCE, 2024,
  • [39] Experimental investigation of heat transfer characteristics in a vertical multi-tube latent heat thermal energy storage system
    Shen, Gang
    Wang, Xiaolin
    Chan, Andrew
    [J]. 2ND INTERNATIONAL CONFERENCE ON ENERGY AND POWER (ICEP2018), 2019, 160 : 332 - 339
  • [40] Experimental investigation on heat transfer and flow resistance performance of RODbaffle multi-tube type of double-tube heat exchanger
    Wang, XS
    Wang, RZ