Treatment of Periprosthetic Hip Fractures Vancouver B1 and C: The Significance of Bicortical Fixation. A Bicentric Study Comparing Two Osteosynthesis Systems

被引:0
|
作者
Tigani, Domenico [1 ]
Calderoni, Enrico Ferranti [1 ]
Melucci, Giuseppe [1 ]
Pizzo, Alex [1 ]
Ghilotti, Margherita [2 ]
Castelli, Alberto [3 ]
Pasta, Gianluigi [3 ]
Grassi, Federico [4 ]
Jannelli, Eugenio [5 ]
机构
[1] Osped Maggiore CA Pizzardi, Dept Orthopaed Surg, Largo B Nigrisoli 2, I-40133 Bologna, Italy
[2] Casa Cura Humanitas San Pio X Milano, Milan, Italy
[3] IRCCS Policlin San Matteo Fdn, Orthoped & Traumatol Clin, I-27100 Pavia, Italy
[4] IRCCS Policlin San Matteo Fdn, Dept Cin Surg Diag & Pediat Sci, Orthoped & Traumatol Clin, I-27100 Pavia, Italy
[5] Univ Pavia, Pavia, Italy
关键词
trauma; periprosthetic; fractures; vancouver classification; FEMORAL FRACTURES; RISK-FACTORS; ARTHROPLASTY; FEMUR; MORTALITY;
D O I
10.52965/001c.117203
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
INTRODUCTION The incidence of periprosthetic fractures (PFFs) is estimated to range from 0.1% to 4.1%1, due to the increasing prevalence of joint arthroplasties, coupled with an aging population. Numerous risk factors, including advanced age (>80 years), female gender, implant type, prior diagnoses of osteonecrosis and rheumatoid arthritis, revision surgery, aseptic stem mobilization, and the use of non-cemented stems, have been identified. Survivors of periprosthetic fractures often experience functional deterioration, facing a fourfold higher risk of hospitalization for postoperative complications compared to patients undergoing primary implantation, especially in the first postoperative year. MATERIALS AND METHODS Between 2018 and 2022, at the Maggiore Hospitals in Bologna and the San Matteo Policlinic in Pavia, we performed osteosynthesis on 84 patients with periprosthetic fractures of Vancouver type B1 or C. In 38 patients, we employed angular stable plates with the Zimmer Biomet NCB-PP (R) system. In 46 patients, we utilized INTRAUMA plates: DF distal femur and PFF proximal. Relevant postoperative follow-up outcomes considered included reintervention, infectious complications, radiographic healing, and functional recovery, with reference to changes in the Glasgow Outcome Scale (GOS) and the Harris Hip Score (HHS). All patients underwent clinical and radiographic evaluations during the follow-up period, averaging 28 months (range: 12-48 months), with a minimum follow-up duration of 12 months. RESULTS At the 4-month postoperative assessment, 71% of patients maintained their preoperative functional level, 19% experienced a 1-point GOS scale drop, and 10% died (GOS 5). The average HHS at 4 months was 80.2 points (range: 65-90). At the 6-month follow-up, 98.2% of patients achieved complete healing on radiographic examination. Only 1 patient (1.2%) developed a pseudoarthrosis site with synthesis device rupture. Only 1 patient (1.2%) required additional surgical treatment 2 years later due to the development of un aseptic perisynthetic fluid collection, while the remaining 5 patients (6%) who developed complications benefited from conservative treatment: 4 patients (3.6%) with infectious complications were treated with intravenous antibiotics. In the 2 patients (2.3%) with mobilization or rupture of synthesis devices, clinical and radiographic monitoring was opted for. 8 patients (10.7%) died: one 48 hours after the surgery, and the other 7 more than one month after the surgery. CONCLUSION Our clinical findings align with to existing scientific literature on periprosthetic fractures (B1 and C according to Vancouver classification). Moreover, good stability has been guaranteed at the radiological follow up by Zimmer Biomet NCB-PP (R) and INTRAUMA DF distal femur and PFF proximal plates. The locking construct allows for improved stability especially in osteoporotic bone.
引用
收藏
页数:7
相关论文
共 46 条
  • [41] Finite element analysis of double-plate fixation using reversed locking compression-distal femoral plates for Vancouver B1 periprosthetic femoral fractures
    Takahashi, Daisuke
    Noyama, Yoshihiro
    Asano, Tsuyoshi
    Shimizu, Tomohiro
    Irie, Tohru
    Terkawi, Mohamad Alaa
    Iwasaki, Norimasa
    BMC MUSCULOSKELETAL DISORDERS, 2021, 22 (01)
  • [42] Unstable Vancouver B1 periprosthetic femoral fracture fixation: A biomechanical comparison between a novel C-shaped memory alloy implant and cerclage wiring
    Oh, Seog-Hyun
    Suh, Yu-Sung
    Eghan-Acquah, Emmanuel
    Yurevich, Kollerov Mikhail
    Won, Sung-Hun
    Baek, Min Jung
    Lee, Sung-Jae
    Choi, Sung-Woo
    JOURNAL OF INTERNATIONAL MEDICAL RESEARCH, 2024, 52 (03)
  • [43] Open reduction and internal fixation (ORIF) versus stem revision (SR) in Vancouver B2 periprosthetic hip fractures: a monocentric, 10-year retrospective study
    Dascal, Adrian
    Steinmetz, Sylvain
    Moerenhout, Kevin
    Cherix, Stephane
    SWISS MEDICAL WEEKLY, 2023, 153 : 54S - 54S
  • [44] Optimal configuration of a three-rod ortho-bridge system in the treatment of Vancouver type B1 periprosthetic femoral fractures: A finite element analysis
    Haque, Md Ariful
    Tovani-Palone, Marcos Roberto
    Franchi, Thomas
    Zhang, Long
    Qin, Jing
    Liu, Luyun
    Zhang, Yingjie
    Xiong, Ying
    Wu, Tong
    Xiao, Jiayu
    JOURNAL OF ORTHOPAEDICS, 2022, 30 : 120 - 126
  • [45] Treatment of periprosthetic femoral fractures type Vancouver B2-Revision arthroplasty vs. open reduction and internal fixation with Locking Compression Plate: A retrospective single center study
    Baum, C.
    Leimbacher, M.
    Kriechling, P.
    Platz, P.
    Cadosch, D.
    BRITISH JOURNAL OF SURGERY, 2017, 104 : 20 - 20
  • [46] C1-ring osteosynthesis versus C1-2 fixation fusion in the treatment of unstable atlas fractures: a multicenter, prospective, randomized controlled study with 5-year follow-up
    Yan, Liang
    Du, Jinpeng
    Yang, Junsong
    He, Baorong
    Hao, Dingjun
    Zheng, Bolong
    Yang, Xiaobin
    Hui, Hua
    Liu, Tuanjiang
    Wang, Xiaodong
    Guo, Hua
    Chen, Jian
    Wang, Shaofei
    Ma, Shengzhong
    Dong, Shengli
    JOURNAL OF NEUROSURGERY-SPINE, 2022, 37 (02) : 157 - 165