Experimental Evaluation and Finite Element Analysis of Stress Distribution in 3D-Printed Dental Implants to Validate the Optimal Thread Pitch

被引:0
|
作者
Irudhayam, Jackson S. [1 ]
Venkatesan, Hariram [1 ]
机构
[1] Hindustan Inst Technol & Sci, Dept Mech Engn, Chennai 603103, Tamil Nadu, India
关键词
photoelasticity test FEA; design CFR PEEK; dental implant; stress distribution; BONE; DIAMETER; LENGTH;
D O I
10.18280/rcma.340215
中图分类号
TB33 [复合材料];
学科分类号
摘要
Objective: As an alternative method of prosthetic rehabilitation, the dental implant serves as one of the solutions that may be used to restore a missing tooth over a lengthy period of time. In order to achieve stress concentration in 3D printed 30% CFR PEEK dental implants, the finite element approach and the experimental photoelasticity test are applied. This is done in order to find the optimal thread pitch for a 3D printed 30% CFR PEEK implant and its impact on the bone implant interface. Materials and methods: Three-dimensional models were generated for the one-piece implant and bone structures. The models were created by introducing variations of 0.8mm, 1mm, and 1.2mm in the thread pitch while maintaining a fixed implant length of 13mm. SolidWorks software was employed for the creation of these models. Subsequently, the stress distribution of the models was simulated under axial load using ANSYS software. An experimental model was created utilizing 3D printing technology, and further experimental tests were conducted to assess the stress concentration in dental implants -bone interfaces. These evaluations were performed using the photoelasticity test method. Results: As a result of the findings, it seems that the implant, cortical, and cancellous bones all exhibit different levels of stress intensity. A thorough analysis of the stress intensity is used to establish the optimal configuration for the pitch of the components and the behavior of 3D printed implant in cancellous bone. Conclusions: After careful consideration, it has been shown that the current finite element model adequately forecasts the stress concentration pattern of dental implants. In light of the fact that the findings of the FEM test are more accurate than those of the photoelasticity test, it is recommended that computation techniques be used in medical practice since they have tremendous potential for new research. This research suggested that the optimum ranges for the length and pitch of the 3D printed 30% CFR PEEK implant are determined to be 13mm and 0.8mm, respectively and a low implant thread pitch results in a reduction in stress concentration at the implantcancellous bone interface.
引用
收藏
页码:257 / 267
页数:11
相关论文
共 50 条
  • [21] Three-Dimensional Finite Element Analysis of Stress Distribution in Zirconia and Titanium Dental Implants
    Villabona Lopez, Camilo Andres
    Amorin Vasco, Marco Antonio
    Ruales, Edwin
    Bedoya, Karin Apaza
    Benfatti, Cesar Magalhaes
    Luis Bezzon, Osvaldo
    Deliberador, Tatiana Miranda
    JOURNAL OF ORAL IMPLANTOLOGY, 2018, 44 (06) : 409 - 415
  • [22] Finite element analysis of stress distribution on dental implants: A study of seven clinical variables.
    Rubo, JH
    Zarb, GA
    Xiao-Yan, L
    Curran, JH
    JOURNAL OF DENTAL RESEARCH, 1998, 77 : 245 - 245
  • [23] Evaluation of the dimensional stability of 3D-printed dental casts
    Vincze, Zsofia Eva
    Kovacs, Zoltan Imre
    Vass, Andrea Fanni
    Borbely, Judit
    Marton, Krisztina
    JOURNAL OF DENTISTRY, 2024, 151
  • [24] Thread Pitch Variant in Orthodontic Mini-screws: A 3-D Finite Element Analysis
    Dastenaei, Fatemeh Motaghi
    Zand, Mahdi Moghimi
    Noorollahian, Saeed
    JOURNAL OF COMPUTATIONAL APPLIED MECHANICS, 2015, 46 (02): : 257 - 265
  • [25] Stress Distribution of Dental Posts by Finite Element Analysis
    Liu, P. H.
    Jhong, G. H.
    5TH KUALA LUMPUR INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING 2011 (BIOMED 2011), 2011, 35 : 219 - 221
  • [26] Influence of Geometric Design Variable and Bone Quality on Stress Distribution for Zirconia Dental Implants-A 3D Finite Element Analysis
    Velmurugan, Duraisamy
    Alphin, Masilamany Santha
    CMES-COMPUTER MODELING IN ENGINEERING & SCIENCES, 2018, 117 (02): : 125 - 141
  • [27] Impact of Dental and Zygomatic Implants on Stress Distribution in Maxillary Defects: A 3-Dimensional Finite Element Analysis Study
    Korkmaz, Fatih Mehmet
    Korkmaz, Yavuz Tolga
    Yalug, Suat
    Korkmaz, Turan
    JOURNAL OF ORAL IMPLANTOLOGY, 2012, 38 (05) : 557 - 568
  • [28] Comparison of 3D-printed and laboratory-fabricated Hyrax on stress distribution and displacement of the maxillary complex: a 3D finite element study
    Bocklet, Michael
    Ahmadi, Farhad
    Tremont, Timothy
    Ross, Loring
    Yao, Hai
    Andrade Jr, Ildeu
    PROGRESS IN ORTHODONTICS, 2024, 25 (01)
  • [29] Comparison of 3D-printed and laboratory-fabricated Hyrax on stress distribution and displacement of the maxillary complex: a 3D finite element study
    Michael Bocklet
    Farhad Ahmadi
    Timothy Tremont
    Loring Ross
    Hai Yao
    Ildeu Andrade
    Progress in Orthodontics, 25
  • [30] Stress Analysis of Zirconia Abutments for Dental Implants by Finite Element Method
    Jiang Songji
    Wu Yin
    Si Wenjie
    RARE METAL MATERIALS AND ENGINEERING, 2015, 44 : 387 - 390