Experimental Evaluation and Finite Element Analysis of Stress Distribution in 3D-Printed Dental Implants to Validate the Optimal Thread Pitch

被引:0
|
作者
Irudhayam, Jackson S. [1 ]
Venkatesan, Hariram [1 ]
机构
[1] Hindustan Inst Technol & Sci, Dept Mech Engn, Chennai 603103, Tamil Nadu, India
关键词
photoelasticity test FEA; design CFR PEEK; dental implant; stress distribution; BONE; DIAMETER; LENGTH;
D O I
10.18280/rcma.340215
中图分类号
TB33 [复合材料];
学科分类号
摘要
Objective: As an alternative method of prosthetic rehabilitation, the dental implant serves as one of the solutions that may be used to restore a missing tooth over a lengthy period of time. In order to achieve stress concentration in 3D printed 30% CFR PEEK dental implants, the finite element approach and the experimental photoelasticity test are applied. This is done in order to find the optimal thread pitch for a 3D printed 30% CFR PEEK implant and its impact on the bone implant interface. Materials and methods: Three-dimensional models were generated for the one-piece implant and bone structures. The models were created by introducing variations of 0.8mm, 1mm, and 1.2mm in the thread pitch while maintaining a fixed implant length of 13mm. SolidWorks software was employed for the creation of these models. Subsequently, the stress distribution of the models was simulated under axial load using ANSYS software. An experimental model was created utilizing 3D printing technology, and further experimental tests were conducted to assess the stress concentration in dental implants -bone interfaces. These evaluations were performed using the photoelasticity test method. Results: As a result of the findings, it seems that the implant, cortical, and cancellous bones all exhibit different levels of stress intensity. A thorough analysis of the stress intensity is used to establish the optimal configuration for the pitch of the components and the behavior of 3D printed implant in cancellous bone. Conclusions: After careful consideration, it has been shown that the current finite element model adequately forecasts the stress concentration pattern of dental implants. In light of the fact that the findings of the FEM test are more accurate than those of the photoelasticity test, it is recommended that computation techniques be used in medical practice since they have tremendous potential for new research. This research suggested that the optimum ranges for the length and pitch of the 3D printed 30% CFR PEEK implant are determined to be 13mm and 0.8mm, respectively and a low implant thread pitch results in a reduction in stress concentration at the implantcancellous bone interface.
引用
收藏
页码:257 / 267
页数:11
相关论文
共 50 条
  • [1] Finite element analysis and experimental evaluation on stress distribution and sensitivity of dental implants to assess optimum length and thread pitch
    Pirmoradian, Mostafa
    Naeeni, Hamed Ajabi
    Firouzbakht, Masih
    Toghraie, Davood
    Khabaz, Mohamad Khaje
    Darabi, Reza
    COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2020, 187
  • [2] A 3D Finite Element Analysis Of Dental Implants With Varying Thread Angles
    NarendraKumar, U.
    Mathew, Arun Tom
    Iyer, Nikhil
    Rahman, Febin
    Manjubala, I.
    MATERIALS TODAY-PROCEEDINGS, 2018, 5 (05) : 11900 - 11905
  • [3] Experimental evaluation of stress distribution with narrow diameter implants: A finite element analysis
    Cinel, Sezgi
    Celik, Ersan
    Sagirkaya, Elcin
    Sahin, Onur
    JOURNAL OF PROSTHETIC DENTISTRY, 2018, 119 (03): : 417 - 425
  • [4] Fatigue life of 3D-printed porous titanium dental implants predicted by validated finite element simulations
    Vautrin, Antoine
    Aw, Jensen
    Attenborough, Ed
    Varga, Peter
    FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2023, 11
  • [5] Comparison of 3D-Printed Dental Implants with Threaded Implants for Osseointegration: An Experimental Pilot Study
    Li, Ling
    Lee, Jungwon
    Ben Amara, Heithem
    Lee, Jun-Beom
    Lee, Ki-Sun
    Shin, Sang-Wan
    Lee, Yong-Moo
    Kim, Byoungkook
    Kim, Pangyu
    Koo, Ki-Tae
    MATERIALS, 2020, 13 (21) : 1 - 10
  • [6] Biomechanical Evaluation of a New Fixation Type in 3D-Printed Periacetabular Implants using a Finite Element Simulation
    Park, Dae Woo
    Lim, Aekyeong
    Park, Jong Woong
    Lim, Kwon Mook
    Kang, Hyun Guy
    APPLIED SCIENCES-BASEL, 2019, 9 (05):
  • [7] Microscale bone interlocking enhances osseointegration strength on the rough surface of 3D-printed titanium implants: experimental and finite element analysis
    Shu, Tianyu
    Shi, Haoyu
    Li, Meng
    Lin, Yu-Chia
    Li, Ang
    Pei, Dandan
    BMC ORAL HEALTH, 2025, 25 (01):
  • [8] Investigation of stress distribution in implant thread design: A 3D Finite Element Analysis
    Jackson Irudhayam, S.
    Hariram, V.
    Materials Today: Proceedings, 2021,
  • [9] Finite element analysis of bone and implant stresses for customized 3D-printed orthopaedic implants in fracture fixation
    Yan, Lina
    Lim, Joel Louis
    Lee, Jun Wei
    Tia, Clement Shi Hao
    O'Neill, Gavin Kane
    Chong, Desmond Y. R.
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2020, 58 (05) : 921 - 931
  • [10] Finite element analysis of bone and implant stresses for customized 3D-printed orthopaedic implants in fracture fixation
    Lina Yan
    Joel Louis Lim
    Jun Wei Lee
    Clement Shi Hao Tia
    Gavin Kane O’Neill
    Desmond Y.R. Chong
    Medical & Biological Engineering & Computing, 2020, 58 : 921 - 931