Cytotoxicity, Corrosion Resistance, and Wettability of Titanium and Ti-TiB2 Composite Fabricated by Powder Metallurgy for Dental Implants

被引:4
|
作者
Aljafery, Ali Mohammad Ali [1 ,2 ]
Fatalla, Abdalbseet A. [2 ]
Haider, Julfikar [3 ]
机构
[1] Univ Kufa, Coll Dent, Dept Prosthodont, Najaf 54001, Iraq
[2] Univ Baghdad, Coll Dent, Dept Prosthodont, Baghdad 1417, Iraq
[3] Manchester Metropolitan Univ, Dept Engn, Manchester M12 5GN, England
关键词
biomaterials; dentistry; titanium; titanium diboride; powder metallurgy; cytotoxicity; corrosion; wettability; TI-TIB COMPOSITES; MATRIX COMPOSITES; MICROSTRUCTURAL CHARACTERIZATION; MECHANICAL-PROPERTIES; BORIDE; DEFORMATION; BEHAVIOR; ALLOYS; EVOLUTION; NICKEL;
D O I
10.3390/met14050538
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Objectives: Orthopedics and dentistry have widely utilized titanium alloys as biomaterials for dental implants, but limited research has been conducted on the fabrication of ceramic particle-reinforced Ti composites for further weight reductions. The current study compared titanium-titanium diboride metal composites (Ti-TiB2) with pure titanium (processed by powder metallurgy) in terms of toxicity, corrosion resistance, and wettability. Methods: First, cell lines of a primary dermal fibroblast normal human adult (HDFa) were used to test the cytocompatibility (in vitro) of the composite and pure Ti using an indirect contact approach. Corrosion testing was performed for the materials using electrochemical techniques such as potentiodynamic polarization in a simulated bodily fluid (SBF) in conjunction with a three-electrode electrochemical cell. The entire set of experimental tests was conducted according to the ASTM F746-04 protocol. The contact angles were measured during wettability testing in accordance with ASTM D7334-08. An X-ray diffractometer (XRD) was used to catalog every phase that was visible in the microstructure. A scanning electron microscope (SEM) and energy-dispersive X-ray spectroscopy (EDS) were used to determine the chemical composition. Results: The cytotoxicity tests revealed that there was no detectable level of toxicity, and there was no significant difference in the impact of either of the two materials on the viability of human fibroblasts. An increase in the corrosion resistance of the composite (0.036 +/- 0.0001 mpy (millimeters per year)) demonstrated the development of a passive oxide coating. According to the findings, the composites showed a greater degree of hydrophilicity (contact angle 44.29 degrees +/- 0.28) than did the pure titanium (56.31 degrees +/- 0.47). Conclusions/Significance: The Ti-TiB2 composite showed no toxicity and better corrosion resistance and wettability than did pure Ti. The composite could be a suitable alternative to Ti for applications involving dental implants.
引用
收藏
页数:18
相关论文
共 29 条
  • [21] Effect of Ti 3 AlC 2 addition on the densification and high- temperature erosion resistance of TiB 2 composite ceramics fabricated by SPS
    Li, Xin
    Tang, Jian
    Qiao, Jia
    Niu, Qun
    Xu, Chen
    Sahin, Filiz Cinar
    Yucel, Onuralp
    JOURNAL OF ALLOYS AND COMPOUNDS, 2024, 1002
  • [22] High-temperature oxidation resistance of a Ti-Al-Sn-Zr titanium matrix composites reinforced with in situ TiC and Ti5Si3 fabricated by powder metallurgy
    Xu, Xiaojing
    Liu, Yangguang
    Tabie, Vitus
    Cai, Chengbin
    Xiao, Yishui
    Zhang, Xu
    Li, Chong
    Jiang, Ze
    Liu, Qingjun
    Chen, Hao
    APPLIED PHYSICS A-MATERIALS SCIENCE & PROCESSING, 2020, 126 (04):
  • [23] Effect of slight Sn modification on mechanical properties and corrosion behavior of Ti- (2-4 wt%) Mn alloys fabricated via powder metallurgy
    Zhou, Xiangxing
    Fang, Haoyu
    Yuan, Tiechui
    Li, Ruidi
    MATERIALS CHARACTERIZATION, 2023, 203
  • [24] Comparison of the structural properties, surface wettability and corrosion resistance of TiO2 nanotubes fabricated on Cp-Ti, Ti6Al4V and Ti45Nb
    Acar, M. T.
    Kovaci, H.
    Celik, A.
    MATERIALS TODAY COMMUNICATIONS, 2022, 33
  • [25] In-situ reinforced Ti6Al4V-TiB2 2 titanium matrix composite fabricated by selective laser melting: Microstructure, mechanical properties and heat treatment
    Li, Yinan
    Fang, Weiping
    Guo, Shun
    Duan, Mengwei
    Luo, Bingbing
    Li, Youkun
    Liu, Jie
    Gu, Jieren
    Peng, Yong
    Zhou, Qi
    Wang, Kehong
    MATERIALS CHARACTERIZATION, 2024, 212
  • [26] Microstructural evolution, corrosion behavior and cytotoxicity of Ti-6Al-4V/ZrO2 composite fabricated by directed energy deposition for implant biomaterial
    Zhou, Xing
    Zhang, Mingxing
    Xu, Dake
    Geng, Shujiang
    Wang, Qiang
    Wang, Fuhui
    JOURNAL OF ALLOYS AND COMPOUNDS, 2022, 892
  • [27] Effects Ti/TiAlN composite multilayer coatings on corrosion resistance of titanium alloy in solid NaCl-H2O-O2 at 600 °C
    Zhang, Mingming
    Xin, Li
    Ding, Xueyong
    Zhu, Shenglong
    Wang, Fuhui
    JOURNAL OF ALLOYS AND COMPOUNDS, 2018, 734 : 307 - 317
  • [28] Improvements in mechanical property and corrosion resistance of Ti-6.5Al-2Zr-1Mo-1V fabricated by laser powder bed fusion using cost-effective modified hydride-dehydrided powder
    Zhang, Xiaohang
    Ran, Xing
    Wang, Zhe
    Han, Changjun
    Du, Zhiheng
    Zhu, Xiangyu
    Zhang, Jiazhen
    Xu, Wei
    Lu, Xin
    MATERIALS SCIENCE AND ENGINEERING A-STRUCTURAL MATERIALS PROPERTIES MICROSTRUCTURE AND PROCESSING, 2024, 916
  • [29] Studies on corrosion resistance and bio-activity of plasma spray deposited hydroxylapatite (HA) based TiO2 and ZrO2 dispersed composite coatings on titanium alloy (Ti-6Al-4V) and the same after post spray heat treatment
    Kumari, Renu
    Majumdar, Jyotsna Dutta
    APPLIED SURFACE SCIENCE, 2017, 420 : 935 - 943