Sensitive Detection of OCS Using Thermal Conversion Combined with Spectral Reconstruction Filtering Differential Optical Absorption Spectroscopy

被引:5
|
作者
Wu, Yongqi [1 ]
Gao, Jie [1 ]
Li, Mu [1 ]
Xie, Fei [1 ]
Li, Wenbo [1 ]
Wu, Xijun [1 ]
Gao, Qiang [2 ]
Zhang, Yungang [1 ]
机构
[1] Yanshan Univ, Sch Elect Engn, Qinhuangdao 066004, Peoples R China
[2] Sch Tianjin Univ, State Key Lab Engines, Tianjin 300072, Peoples R China
基金
中国国家自然科学基金;
关键词
CARBONYL SULFIDE OCS; VOLATILE SULFUR-COMPOUNDS; BREATH BIOMARKERS; HYDROGEN-SULFIDE; CROSS-SECTIONS; DISULFIDE; OXIDATION; SYSTEM; DIOXIDE; COS;
D O I
10.1021/acs.analchem.4c00943
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Carbonyl sulfide (OCS) is a toxic gas produced during industrial processes that poses risks to both human health and industrial equipment. Therefore, detecting OCS concentrations plays a crucial role in early hazard warning. This paper presents an online system for detecting OCS at the ppb level using thermal conversion and spectral reconstruction filtering differential optical absorption spectroscopy (SRF-DOAS). First, OCS, which is not suitable for DOAS due to its weak absorption characteristics, is completely transformed into SO2 with strong absorption characteristics under high-temperature conditions. Then, the spectral reconstruction filtering method (SRF) is proposed to eliminate the noise and interference. The core idea of the method is to arrange the spectrum according to the spectral intensity from small to large rather than wavelength, reconstructing the spectrum into a new spectrum with linear characteristics. The reconstructed spectrum can remove noise and interference by linear fitting and retain the characteristic of SO2 oscillation absorption. Next, we demonstrate the ability of the reconstructed spectral method to remove noise and interference by comparing the spectra of the inverse-reconstructed gas mixture and SO2. The relative deviation of 0.88% at 100 ppb and detection limit of 7.26 ppb*m for OCS were obtained using the SRF-DOAS method. Finally, the reliability of the system was confirmed by measurements of OCS concentrations in mixture gas of OCS and air, as well as in human exhaled breath.
引用
收藏
页码:8696 / 8704
页数:9
相关论文
共 50 条
  • [31] Differential optical absorption spectroscopy-based refractive index sensor for cancer cell detection
    Tarunnum Parvin
    Kawsar Ahmed
    Aadel M. Alatwi
    Ahmed Nabih Zaki Rashed
    Optical Review, 2021, 28 : 134 - 143
  • [32] A photonic crystal fiber sensor based on differential optical absorption spectroscopy for mixed gases detection
    Wu, Baoqun
    Lu, Ying
    Hao, Congjing
    Duan, Liangcheng
    Musideke, Mayilamu
    Yao, Jianquan
    OPTIK, 2014, 125 (12): : 2909 - 2911
  • [33] Differential optical absorption spectroscopy-based refractive index sensor for cancer cell detection
    Parvin, Tarunnum
    Ahmed, Kawsar
    Alatwi, Aadel M.
    Rashed, Ahmed Nabih Zaki
    OPTICAL REVIEW, 2021, 28 (01) : 134 - 143
  • [34] PHOTOPYROELECTRIC (PPE) PHASE SPECTROSCOPY FOR SENSITIVE OPTICAL-ABSORPTION COEFFICIENT AND THERMAL-DIFFUSIVITY MEASUREMENT
    FRANDAS, A
    CHIRTOC, M
    CANDEA, RM
    SPECTROSCOPY LETTERS, 1992, 25 (08) : 1155 - 1163
  • [35] Measurement of air pollutants by differential optical absorption spectroscopy using a Cassegrain telescope with fibers
    李红莲
    魏永杰
    侯艳霞
    陈文亮
    Optoelectronics Letters, 2013, 9 (04) : 313 - 316
  • [36] Summertime measurements of benzene and toluene in Athens using a differential optical absorption spectroscopy system
    Petrakis, M
    Psiloglou, B
    Kassomenos, PA
    Cartalis, C
    JOURNAL OF THE AIR & WASTE MANAGEMENT ASSOCIATION, 2003, 53 (09): : 1052 - 1064
  • [37] Measurement of air pollutants by differential optical absorption spectroscopy using a Cassegrain telescope with fibers
    Li H.-L.
    Wei Y.-J.
    Hou Y.-X.
    Chen W.-L.
    Optoelectronics Letters, 2013, 9 (4) : 313 - 316
  • [38] Retrieval interval mapping: a tool to visualize the impact of the spectral retrieval range on differential optical absorption spectroscopy evaluations
    Vogel, L.
    Sihler, H.
    Lampel, J.
    Wagner, T.
    Platt, U.
    ATMOSPHERIC MEASUREMENT TECHNIQUES, 2013, 6 (02) : 275 - 299
  • [39] Interrogation of wavelength, multiplexed fiber Bragg gratings using spectral filtering and amplitude-to-phase optical conversion
    Abad, S
    Araújo, FM
    Ferreira, LA
    Santos, JL
    López-Amo, M
    JOURNAL OF LIGHTWAVE TECHNOLOGY, 2003, 21 (01) : 127 - 131
  • [40] PHASE-SENSITIVE DETECTION OF PERSISTENT SPECTRAL HOLES USING SYNCHRONOUS ULTRASONIC MODULATION SPECTROSCOPY
    MOERNER, WE
    HUSTON, AL
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA B-OPTICAL PHYSICS, 1986, 3 (08) : P210 - P210