Dynamic identification and vibration serviceability assessment of a wooden cable-stayed footbridge

被引:0
|
作者
Nicoletti, Vanni [1 ]
Tentella, Luca [1 ]
Martini, Riccardo [1 ]
Quarchioni, Simone [1 ]
Carbonari, Sandro [1 ]
Gara, Fabrizio [1 ]
机构
[1] Univ Politecn Marche, Dept Construct Civil Engn & Architecture DICEA, Via Brecce Bianche, I-60131 Ancona, Italy
关键词
Steel and wooden footbridge; Footbridge dynamic testing; Ambient vibration tests; Human-induced vibration tests; Footbridge vibration serviceability assessment;
D O I
10.1002/cepa.2124
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
This paper discusses the dynamic characterization of a 3 spans wooden cable-stayed footbridge newly built in Italy. The footbridge is 235 m long and consists of a 2-girder wooden deck. The edge spans are simply supported, while the mid one (about 150 m long) is sustained by 16 stays linked to 2 pillars. Ambient vibration tests and operational modal analyses are performed to identify the global dynamic behaviour of the structure and 17 stable vibration modes are identified in the frequency range 0-6 Hz. Moreover, the vibration serviceability is assessed performing in situ pedestrian load tests following the load protocols provided by Hivoss and Setra technical guidelines, and verifying the recorded accelerations with the maximum ones suggested by codes (fib bulletin 32 and EN1990:2002).
引用
收藏
页码:1174 / 1181
页数:8
相关论文
共 50 条
  • [31] In situ testing and nonlinear modelling for a cable-stayed timber footbridge
    Bortoluzzi, Daniele
    Casciati, Fabio
    Casciati, Sara
    Faravelli, Lucia
    [J]. CSNDD 2014 - INTERNATIONAL CONFERENCE ON STRUCTURAL NONLINEAR DYNAMICS AND DIAGNOSIS, 2014, 16
  • [32] Human-induced vibrations of a curved cable-stayed footbridge
    Bassoli, Elisa
    Gambarelli, Paola
    Vincenzi, Loris
    [J]. JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2018, 146 : 84 - 96
  • [33] Size and post-tensioning cable force optimization of cable-stayed footbridge
    Atmaca, Barbaros
    [J]. STRUCTURES, 2021, 33 : 2036 - 2049
  • [34] IMPORTANCE OF CABLE VIBRATION IN DYNAMICS OF CABLE-STAYED BRIDGES
    ABDELGHAFFAR, AM
    KHALIFA, MA
    [J]. JOURNAL OF ENGINEERING MECHANICS-ASCE, 1991, 117 (11): : 2571 - 2589
  • [35] Modeling of cable vibration effects of cable-stayed bridges
    S.H.Cheng
    David T.Lau
    [J]. Earthquake Engineering and Engineering Vibration, 2002, 1 (01) : 74 - 85
  • [36] Modeling of cable vibration effects of cable-stayed bridges
    Cheng S.H.
    Lau D.T.
    [J]. Earthquake Engineering and Engineering Vibration, 2002, 1 (1) : 74 - 85
  • [37] Dynamic and aeroelastic behaviour of a twin deck curved cable-stayed footbridge equipped with passive devices
    Tondini, Nicola
    Bursi, Oreste S.
    Bonelli, Alessio
    Francescotti, Stefano
    [J]. PROCEEDINGS OF THE 8TH INTERNATIONAL CONFERENCE ON STRUCTURAL DYNAMICS, EURODYN 2011, 2011, : 1829 - 1835
  • [38] Vibration Serviceability Assessment of a Historic Suspension Footbridge
    Bayat, Elyas
    Milone, Angelo
    Tubino, Federica
    Venuti, Fiammetta
    [J]. BUILDINGS, 2022, 12 (06)
  • [39] Free vibration analysis of cable-stayed bridges by dynamic stiffness method
    Cheung, YK
    Au, FTK
    Cheng, YS
    Zheng, DY
    [J]. STRUCTURAL DYNAMICS, VOLS 1 AND 2, 1999, : 777 - +
  • [40] Modal identification from ambient vibration tests on a cable-stayed bridge
    Rodrigues, J.
    Xu, M.
    Santos, L. O.
    [J]. Structural Dynamics - EURODYN 2005, Vols 1-3, 2005, : 155 - 160