Pulmonary vein reconnection and repeat ablation characteristics following cryoballoon-compared to radiofrequency-based pulmonary vein isolation

被引:3
|
作者
Obergassel, J. [1 ,2 ]
Nies, M. [1 ,2 ]
Taraba, S. [1 ]
Rottner, L. [1 ]
Lemoine, M. D. [1 ]
My, I. [1 ]
Moser, F. [1 ]
Riess, J. L. [1 ,2 ]
Schenker, N. [1 ]
Dinshaw, L. [1 ]
Schleberger, R. [1 ]
Reissmann, B. [1 ]
Meyer, C. [2 ,3 ,4 ]
Willems, S. [2 ,5 ]
Rillig, A. [1 ]
Kirchhof, P. [1 ,2 ,6 ]
Metzner, A. [1 ]
机构
[1] Univ Med Ctr Hamburg Eppendorf, Univ Heart & Vasc Ctr Hamburg, Dept Cardiol, Martinistr 52, D-20253 Hamburg, Germany
[2] German Ctr Cardiovasc Res DZHK, Partner Site Hamburg Kiel Lubeck, Lubeck, Germany
[3] EVK Dusseldorf, Cardiac Neuro & Electrophysiol Res Consortium, Dept Cardiol Angiol & Intens Care, cNEP, Dusseldorf, Germany
[4] Heinrich Heine Univ Dusseldorf, Inst Neural & Sensory Physiol, cNEP, Med Fac,Cardiac Neuro & Electrophysiol Res Consort, Dusseldorf, Germany
[5] Asklepios Klin St Georg, Dept Cardiol, Hamburg, Germany
[6] Univ Birmingham, Inst Cardiovasc Sci, Birmingham, England
基金
英国医学研究理事会;
关键词
cryoballoon ablation; energy; pulmonary vein reconnection; radiofrequency ablation; reisolation; repeat ablation; ATRIAL-FIBRILLATION; 2ND-GENERATION CRYOBALLOON; CATHETER ABLATION; TACHYCARDIA;
D O I
10.1111/jce.16343
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Despite advances in efficacy and safety of pulmonary vein isolation (PVI), atrial fibrillation (AF) recurrence after PVI remains common. PV-reconnection is the main finding during repeat PVI procedures performed to treat recurrent AF. Objective: To analyze pulmonary vein (PV) reconnection patterns during repeat ablation procedures in a large cohort of consecutive patients undergoing radio frequency or cryoballoon-based PVI. Methods: Retrospective analysis of PV-reconnection patterns and analysis of re-ablation strategies in consecutive index RF- and CB-based PVI and their respective re-ablation procedures during concomitant usage of both energy sources at a single high-volume center in Germany. Results: A total of 610 first (06/2015-10/2022) and 133 s (01/2016-11/2022) repeat ablation procedures after 363 (60%) RF- and 247 (40%) CB-based index PVIs between 01/2015 and 12/2021 were analyzed. PV-reconnection was found in 509/610 (83%) patients at first and 74/133 (56%) patients at second repeat procedure. 465 of 968 (48%) initially via CB isolated PVs were reconnected at first re-ablation but 796 of 1422 initially RF-isolated PV (56%) were reconnected (OR: 0.73 [95% CI: 0.62-0.86]; p < .001). This was driven by fewer reconnections of the left PVs (LSPV: OR: 0.60 [95% CI: 0.42-0.86]; p = .005 and LSPV: 0.67 [0.47-0.95]; p = .026). PV-reconnection was more likely after longer, RF-based index PVI and in older females. Repeat procedures were shorter after CB-compared to after RF-PVI. Conclusions: Reconnection remains the most common reason for repeat AF ablation procedures after PVI. Our data suggest to preferentially use of the cryoballoon during index PVI, especially in older women.
引用
收藏
页码:1766 / 1778
页数:13
相关论文
共 50 条
  • [1] Pulmonary vein reconnection and repeat ablation characteristics following cryoballoon- compared to radio frequency-based pulmonary vein isolation
    Obergassel, J.
    Nies, M.
    Kirchhof, P.
    Metzner, A.
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2024, 35 (10) : 2085 - 2085
  • [2] Evaluation of pulmonary vein reconnection during repeat ablation for atrial fibrillation, following primary pulmonary vein isolation using laser balloon ablation as compared to radiofrequency catheter ablation
    Koopman, P.
    Brughmans, S.
    Dilling-Boer, D.
    Knevels, R.
    Leenders, F.
    Phlips, T.
    Schurmans, J.
    Vijgen, J.
    ACTA CARDIOLOGICA, 2022, 77 : 14 - 14
  • [3] Cryoballoon ablation for pulmonary vein isolation
    Andrade, Jason G.
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2020, 31 (08) : 2128 - 2135
  • [4] CHARACTERIZATION OF PULMONARY VEIN RECONNECTION POST CRYOBALLOON ABLATION
    Shah, Shivang
    Xu, Wenjie
    Adelstein, Evan
    Voigt, Andrew
    Saba, Samir
    Jain, Sandeep
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2017, 69 (11) : 399 - 399
  • [5] Comparison of the clinical outcome of pulmonary vein isolation with cryoballoon and radiofrequency ablation for atrial fibrillation with pulmonary vein triggers
    Nitta, G.
    Inaba, O.
    Kato, S.
    Kono, T.
    Ikenouchi, T.
    Murata, K.
    Matsuda, J.
    Kanoh, M.
    Inamura, Y.
    Takamiya, T.
    Negi, K.
    Sato, A.
    Yamato, T.
    Matsumura, Y.
    Nitta, J.
    EUROPEAN HEART JOURNAL, 2019, 40 : 1208 - 1208
  • [6] Pulmonary vein size is associated with reconnection following cryoballoon ablation of atrial fibrillation
    Giacomo Mugnai
    Federico Cecchini
    Erwin Stroker
    Gaetano Paparella
    Saverio Iacopino
    Juan Sieira
    Yves De Greef
    Luca Tomasi
    Bruna Bolzan
    Gezim Bala
    Ingrid Overeinder
    Alexandre Almorad
    Anais Gauthey
    Antonio Sorgente
    Flavio Luciano Ribichini
    Carlo de Asmundis
    Gian-Battista Chierchia
    Journal of Interventional Cardiac Electrophysiology, 2022, 65 : 717 - 724
  • [7] Troponin release after pulmonary vein isolation using pulsed field ablation compared to radiofrequency and cryoballoon ablation
    Krisai, Philipp
    Knecht, Sven
    Badertscher, Patrick
    Muhl, Aline
    Osswald, Stefan
    Roten, Laurent
    Reichlin, Tobias
    Sticherling, Christian
    Kuhne, Michael
    HEART RHYTHM, 2022, 19 (09) : 1471 - 1472
  • [8] Pulmonary vein size is associated with reconnection following cryoballoon ablation of atrial fibrillation
    Mugnai, Giacomo
    Cecchini, Federico
    Stroker, Erwin
    Paparella, Gaetano
    Iacopino, Saverio
    Sieira, Juan
    De Greef, Yves
    Tomasi, Luca
    Bolzan, Bruna
    Bala, Gezim
    Overeinder, Ingrid
    Almorad, Alexandre
    Gauthey, Anais
    Sorgente, Antonio
    Ribichini, Flavio Luciano
    de Asmundis, Carlo
    Chierchia, Gian-Battista
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2022, 65 (03) : 717 - 724
  • [9] Early Cryoballoon Pulmonary Vein Isolation Ablation Experience in Radiofrequency Ablation Experienced Operators
    Siddoway, Donald
    Friehling, Mati
    Voigt, Andrew
    Saba, Samir
    Jain, Sandeep
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2014, 25 (05) : 569 - 569
  • [10] MRI characterization of cryoballoon and radiofrequency ablation lesions after pulmonary vein isolation
    Cabanas Grandio, P.
    Bisbal, F.
    Gomez Pulido, F.
    Guiu, E.
    Calvo, M.
    Berruezo, A.
    Prat, S.
    Perea, R. J.
    Brugada, J.
    Mont, L.
    EUROPEAN HEART JOURNAL, 2014, 35 : 428 - 428