Chemiluminescence data modeling using parallel factor analysis for the simple and sensitive determination of diphenoxylate in human plasma and tablets

被引:1
|
作者
Koohsarian, Maryam [1 ]
Mokhtari, Ali [1 ,2 ]
Hooshmand, Shabnam [1 ]
机构
[1] Golestan Univ, Dept Chem, Gorgan, Iran
[2] Golestan Univ, Fac Sci, Dept Chem, Lab Analyt Chem, Gorgan 4913815759, Iran
关键词
blood plasma; chemiluminescence; diphenoxylate; PARAFAC; TIME-RESOLVED CHEMILUMINESCENCE; STOPPED-FLOW DETERMINATION; ATROPINE SULFATE; HYDROCHLORIDE; FORMULATIONS; ACID; COBALT(II); OXIDATION;
D O I
10.1002/bio.4805
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this study, a chemiluminescence (CL) method was developed to determine diphenoxylate in tablets and human plasma. This is the first CL method proposed to determine diphenoxylate. Creating three-dimensional data caused the parallel factor analysis algorithm (PARAFAC) to be used for the first time in CL methods. The method is based on the fact that diphenoxylate enhances the weak CL produced in the reaction of Ru(phen)32+ and acidic Ce(IV), and the concentration of Ce(IV) solution has a different effect on the CL response of diphenoxylate and the blank plasma. The calibration curve was linear from 4.0 x 10-8 to 1.6 x 10-6 mol L-1 (R2 = 0.9954), and the detection limit was 1.3 x 10-8 mol L-1 (S/N = 3). The sampling rate was about 30 samples per hour, and the % RSD for 10 repeated measurements of 4 x 10-7 mol L-1 diphenoxylate was 5.4%. The interference effects of some ions, amino acids, and common additives were also investigated. The CL method was successfully used to determine diphenoxylate in tablets, and the results were statistically confirmed by the reference method. The proposed CL method and the PARAFAC algorithm were successfully used to determine the concentration of diphenoxylate in human blood plasma samples. The PARAFAC model used the three-way chemiluminescence data matrix to predict diphenoxylate concentration in human plasma. image
引用
收藏
页数:11
相关论文
共 50 条
  • [21] Sensitive assay for catecholamines in pharmaceutical samples and blood plasma using flow injection chemiluminescence analysis
    Yu, CL
    Tang, YH
    Han, XN
    Zheng, XH
    ANALYTICAL SCIENCES, 2006, 22 (01) : 25 - 28
  • [22] Sensitive Assay for Catecholamines in Pharmaceutical Samples and Blood Plasma Using Flow Injection Chemiluminescence Analysis
    Chunling Yu
    Yuhai Tang
    Xiaonian Han
    Xiaohui Zheng
    Analytical Sciences, 2006, 22 : 25 - 28
  • [23] Specific, highly sensitive and simple spectrofluorimetric method for quantification of daclatasvir in HCV human plasma patients and in tablets dosage form
    Ali, Ramadan
    Elsutohy, Mohamed M.
    OPEN CHEMISTRY, 2019, 17 (01): : 116 - 126
  • [24] A sensitive chemiluminescence determination of isoproterenol in pharmaceutical and human serum using luminol-diperiodatoargentate(III) system
    Rezaei, Behzad
    Ensafi, Ali A.
    Haghighatnia, Fariba
    ANALYTICAL METHODS, 2012, 4 (06) : 1573 - 1578
  • [25] Simple, sensitive and rapid HPLC-MS/MS method for the determination of cepharanthine in human plasma
    Hao, Guangtao
    Liang, Haixia
    Li, Yuanyuan
    Li, Haiyan
    Gao, Hongzhi
    Liu, Guang
    Liu, Zeyuan
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2010, 878 (28): : 2923 - 2927
  • [26] A simple and sensitive HPLC-ESI-MS/MS method for the determination of andrographolide in human plasma
    Xu, Li
    Xiao, Da-wei
    Lou, Sheng
    Zou, Jian-jun
    Zhu, Yu-bing
    Fan, Hong-wei
    Wang, Guang-ji
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2009, 877 (5-6): : 502 - 506
  • [27] Fluorescent quantification of terazosin hydrochloride content in human plasma and tablets using second-order calibration based on both parallel factor analysis and alternating penalty trilinear decomposition
    Zou, Hong-Yan
    Wu, Hai-Long
    OuYang, Li-Qun
    Zhang, Yan
    Nie, Jin-Fang
    Fu, Hai-Yan
    Yu, Ru-Qin
    ANALYTICA CHIMICA ACTA, 2009, 650 (01) : 143 - 149
  • [28] Flow-injection chemiluminescence analysis for sensitive determination of atenolol using cadmium sulfide quantum dots
    Khataee, Alireza
    Lotfi, Roya
    Hasanzadeh, Aliyeh
    Iranifam, Mortaza
    Joo, Sang Woo
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2016, 157 : 88 - 95
  • [29] Simple and sensitive determination of nisoldipine in plasma using liquid chromatography-tandem mass spectrometry
    Kang, Wonku
    ANALYTICAL SCIENCES, 2006, 22 (12) : 1597 - 1599
  • [30] Simple and Sensitive Determination of Nisoldipine in Plasma Using Liquid Chromatography-Tandem Mass Spectrometry
    Wonku Kang
    Analytical Sciences, 2006, 22 : 1597 - 1599