Reliability of ultrasound real-time tissue elastography in evaluating swallowing-related muscle elasticity and effects of swallowing exercises

被引:0
|
作者
Ota, Tetsuo [1 ]
Madokoro, Sachiko [1 ]
Shimizu, Koshi [2 ,3 ]
Yoneda, Mitsugu [1 ]
机构
[1] Kanazawa Univ, Inst Med Pharmaceut & Hlth Sci, Fac Hlth Sci, 5-11-80 Kodatsuno, Kanazawa, Ishikawa 9200942, Japan
[2] Kanazawa Univ, Grad Sch Med Sci, Div Hlth Sci, Kanazawa, Ishikawa, Japan
[3] Keyaki Clin, Dept Rehabil, Kanazawa, Ishikawa, Japan
关键词
muscle elasticity; real-time tissue elastography; reliability; swallowing; swallowing-related muscles; ultrasound; STRAIN RATIO; HARDNESS; STIFFNESS; LESIONS; BENIGN;
D O I
10.1002/sono.12459
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
IntroductionEvaluating swallowing function, essential for eating, is necessary to detect functional decline, enabling the provision of effective interventions. There is a growing demand for a simple method for evaluating swallowing dynamics. Conventional methods of evaluating swallowing function, such as the fibreoptic endoscopic evaluation of swallowing or videofluoroscopic swallowing study, are highly invasive and require specific equipment only available at certain hospitals, making it difficult for older adults to receive convenient evaluations. Therefore, we used ultrasound real-time tissue elastography (RTE), a low-invasive method, to evaluate tissue elasticity as the strain ratio (SR). This study primarily aimed to verify whether RTE can evaluate the elasticity of swallowing-related muscles (SRMs) and determine intra- and inter-rater reliabilities. The secondary aim was to investigate the effect of swallowing exercises, such as head-lifting exercises, on SRM elasticity.MethodsIntraclass correlation coefficients for SR were calculated using ultrasound B-mode images to determine the reliability of SRM elasticity. SRs before and after the Shaker swallowing exercise were compared using the Wilcoxon signed-rank test.ResultsHigh ICCs for intra- and inter-rater reliabilities were obtained for all targeted SRMs. SR after the Shaker exercise indicated a significant decrease in the geniohyoid muscle and both sides of the digastric muscles, whereas both sides of the masseter exhibited no changes.ConclusionRTE can be used as a novel simple and non-invasive method for assessing and capturing differences in SRs of SRMs after light exercise. Further research may develop a relationship with swallowing function in patients with dysphagia or older individuals.
引用
收藏
页码:60 / 69
页数:10
相关论文
共 50 条
  • [21] Effects of Motor Imagery and Visual Neurofeedback on Activation in the Swallowing Network: A Real-Time fMRI Study
    Kober, Silvia Erika
    Groessinger, Doris
    Wood, Guilherme
    DYSPHAGIA, 2019, 34 (06) : 879 - 895
  • [22] Upper trapezius muscle elasticity in cervical myofascial pain syndrome measured using real-time ultrasound shear-wave elastography
    Hao, Chang-Juan
    Kang, Xiao-Yan
    Kang, Chun-Song
    Li, Ting-Ting
    Huo, Jian-Zhong
    Xu, Qian
    Xiao, Wen-Li
    Zhao, Zhe-Xia
    Ji, Xing-Hua
    Zhang, Quan-Bin
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2023, 13 (08) : 5168 - 5181
  • [23] Magnetic resonance imaging, ultrasound and real-time ultrasound elastography of the thigh muscles in congenital muscle dystrophy
    Eleni E. Drakonaki
    Gina M. Allen
    Skeletal Radiology, 2010, 39 : 391 - 396
  • [24] Magnetic resonance imaging, ultrasound and real-time ultrasound elastography of the thigh muscles in congenital muscle dystrophy
    Drakonaki, Eleni E.
    Allen, Gina M.
    SKELETAL RADIOLOGY, 2010, 39 (04) : 391 - 396
  • [25] An evaluation of ocular elasticity using real-time ultrasound elastography in primary open-angle glaucoma
    Agladioglu, Kadir
    Pekel, Gokhan
    Kasikci, Seher Altintas
    Yagci, Ramazan
    Kiroglu, Yilmaz
    BRITISH JOURNAL OF RADIOLOGY, 2016, 89 (1060):
  • [26] Contractile property measurement of the torn supraspinatus muscle using real-time tissue elastography
    Yuri, Takuma
    Mura, Nariyuki
    Yuki, Issei
    Fujii, Hiromi
    Kiyoshige, Yoshiro
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2018, 27 (09) : 1700 - 1704
  • [27] Real-time ultrasound elastography-a noninvasive diagnostic procedure for evaluating dominant thyroid nodules
    Vorlaender, Christian
    Wolff, Jan
    Saalabian, Said
    Lienenlueke, Robert H.
    Wahl, Robert A.
    LANGENBECKS ARCHIVES OF SURGERY, 2010, 395 (07) : 865 - 871
  • [28] Normal values of liver elasticity measured by real-time tissue elastography (RTE) in healthy infants and children
    Selmi, Buket
    Engelmann, Guido
    Teufel, Ulrike
    El Sakka, Saroa
    Dadrich, Monika
    Schenk, Jens-Peter
    JOURNAL OF MEDICAL ULTRASONICS, 2014, 41 (01) : 31 - 38
  • [29] DETERMINATION OF THE ELASTICITY OF BREAST TISSUE DURING THE MENSTRUAL CYCLE USING REAL-TIME SHEAR WAVE ELASTOGRAPHY
    Li, Xiang
    Wang, Jian-Nan
    Fan, Zhi-Ying
    Kang, Shu
    Liu, Yan-Jun
    Zhang, Yi-Xia
    Wang, Xue-Mei
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2015, 41 (12): : 3140 - 3147
  • [30] Normal values of liver elasticity measured by real-time tissue elastography (RTE) in healthy infants and children
    Buket Selmi
    Guido Engelmann
    Ulrike Teufel
    Saroa El Sakka
    Monika Dadrich
    Jens-Peter Schenk
    Journal of Medical Ultrasonics, 2014, 41 : 31 - 38