A challenge for high-speed and high-resolution CT for extremities with clinical feasibility

被引:0
|
作者
Kawashima, Hiroki [1 ]
Ichikawa, Katsuhiro [1 ]
机构
[1] Kanazawa Univ, Inst Med Pharmaceut & Hlth Sci, 5-11-80 Kodatsuno, Kanazawa, Ishikawa 9200942, Japan
关键词
computed tomography; high resolution; extremity; bone; image quality;
D O I
10.1117/12.3004919
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
Existing micro-CT systems can visualize the trabecular bone microstructure; however, its application is limited because of the small scan field of view and the long scan time for clinical use. We developed a high-resolution CT for human extremities (HRCTe) with clinical feasibility, which can achieve a spatial resolution of similar to 100 mu m and a short acquisition time of 6.5 seconds. A complementary metal-oxide-semiconductor X-ray detector with a 99-mu m pixel pitch and a compact X-ray tube with a focal spot size of 0.8 mm were installed in the HRCTe. In order to maximize the performance of the Xray tube and the detector, we introduced a low-magnification geometry. This resulted in an effective focal spot size of 0.14 mm, ensuring the resolution performance of the pixel pitch at the iso-center of 81 mu m. The scan z-directional coverage was 50 mm. For the technical assessment, modulation transfer function (MTF) and noise power spectrum (NPS) were measured using a wire phantom and a water phantom, respectively. A squared system performance function (SPF2) was calculated as MTF2/NPS. These results were compared with those measured using a high-resolution mode of a whole-body CT with a 0.25-mm detector (WCT) and a dental CT (DCT). The 5%MTF of the HRCT, WCT, and DCT were approximately 3.8, 1.9, and 1.5 mm(-1). The SPF2 at 2.0 mm(-1) of the developed CT was 260% higher than that of WCT. The trabecular bones in an anthropomorphic foot phantom were visualized much clearer with HRCTe than with both WCT and DCT.
引用
收藏
页数:5
相关论文
共 50 条
  • [21] LIGHT GATES FOR HIGH-RESOLUTION, HIGH-SPEED PRINTING
    DORN, R
    [J]. ELECTRICAL COMMUNICATION, 1988, 62 (3-4): : 229 - 234
  • [22] On the design of high-speed high-resolution track and holds
    Caiulo, G
    Fiocchi, C
    Gatti, U
    Maloberti, F
    [J]. ISCAS 96: 1996 IEEE INTERNATIONAL SYMPOSIUM ON CIRCUITS AND SYSTEMS - CIRCUITS AND SYSTEMS CONNECTING THE WORLD, VOL 1, 1996, : 73 - 76
  • [23] High-resolution, high-speed confocal Raman imaging
    Dieing, Thomas
    Hollricher, Olaf
    [J]. VIBRATIONAL SPECTROSCOPY, 2008, 48 (01) : 22 - 27
  • [24] DESIGN TECHNIQUES FOR HIGH-SPEED, HIGH-RESOLUTION COMPARATORS
    RAZAVI, B
    WOOLEY, BA
    [J]. IEEE JOURNAL OF SOLID-STATE CIRCUITS, 1992, 27 (12) : 1916 - 1926
  • [25] High-resolution, high-speed photoacoustic microscopy and photoplethysmography for clinical applications in human fingers
    Ahn, Joongho
    Baik, Jinwoo
    Kim, Hyojin
    Kim, Yeonggeun
    Kim, Jin Young
    Kim, Hyung Ham
    Kim, Chulhong
    [J]. PHOTONS PLUS ULTRASOUND: IMAGING AND SENSING 2022, 2022, 11960
  • [26] A Novel Platform for High-Speed, High-Resolution LIBS Imaging
    Harrel, Shayne
    Laurent, Jean-Michel
    Varagnat, Antoine
    Tercier, Adrian
    Motto-Ros, Vincent
    [J]. PHOTONIC INSTRUMENTATION ENGINEERING X, 2023, 12428
  • [27] A novel A/D converter for high-resolution and high-speed applications
    Ehsanian, M
    BenHamida, N
    Kaminska, B
    [J]. ISCAS '97 - PROCEEDINGS OF 1997 IEEE INTERNATIONAL SYMPOSIUM ON CIRCUITS AND SYSTEMS, VOLS I - IV: CIRCUITS AND SYSTEMS IN THE INFORMATION AGE, 1997, : 433 - 436
  • [28] A survey of high-speed high-resolution current steering DACs
    Li, Xing
    Zhou, Lei
    [J]. JOURNAL OF SEMICONDUCTORS, 2020, 41 (11)
  • [29] A HIGH-SPEED DIGITAL FREQUENCY-SYNTHESIZER WITH HIGH-RESOLUTION
    NAZARENKO, VM
    ILINSKIY, IV
    SHAKHTARIN, BI
    [J]. TELECOMMUNICATIONS AND RADIO ENGINEERING, 1982, 36-7 (06) : 97 - 100
  • [30] Intelligent, High-speed, High-resolution, and Tomographic Phase Microscopy
    Zhou, Renjie
    [J]. BIOMEDICAL IMAGING AND SENSING CONFERENCE 2020, 2020, 11521