Concurrent validity and test - retest reliability of VALD ForceDecks' strength, balance, and movement assessment tests

被引:6
|
作者
Collings, Tyler J. [1 ,2 ]
Lima, Yuri Lopes [1 ,2 ]
Dutaillis, Benjamin [1 ,2 ]
Bourne, Matthew N. [1 ,2 ]
机构
[1] Griffith Univ, Sch Hlth Sci & Social Work, Gold Coast Campus, Gold Coast, Australia
[2] Griffith Univ, Menzies Hlth Inst Queensland, Griffith Ctr Biomed & Rehabil Engn GCORE, Gold Coast Campus, Gold Coast, Australia
关键词
Force plate; Ground reaction force; Center of pressure; Jump testing; Isometric strength; Measurement properties; JUMP;
D O I
10.1016/j.jsams.2024.04.014
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
Objectives: To evaluate the concurrent validity and test-retest reliability of common movement, strength, and balance tests using portable uniaxial dual force plates. Design: Repeated measures cross-sectional study. Methods: Sixteen healthy individuals participated in two testing sessions, where they performed 12 different movement, strength, and balance tests. Vertical ground reaction force and centre of pressure data were collected using the VALD ForceDecks simultaneously with ground-embedded laboratory force plates. Concurrent validity was assessed using root mean square error for raw time-series data and Bland-Altman plots for discrete metrics. Test-retest reliability was assessed using intraclass correlation coefficients and minimal detectable changes. Results: ForceDecks recorded vertical ground reaction forces and center of pressure with high accuracy compared to laboratory force plates. The mean bias between systems was negligible (<2 N or 0.1 mm), with small limits of agreement (<5 N or 1 mm). Overall, 530/674 (79%) showed good or excellent validity (<10% difference) and 611/773 (79%) had good or excellent reliability (intraclass correlation coefficient >0.75). ForceDecks reliability was similar to laboratory force plates (<0.07 intraclass correlation coefficient median difference for all metrics). Conclusions: Portable uniaxial force plates record highly accurate vertical ground reaction forces and center of pressure during a range of movement, strength, and balance tests. The VALD ForcDecks are a valid and reliable alternative to laboratory force plates when strict standardized testing and data analysis procedures are followed. Users should be aware of the validity and reliability characteristics of the tests and metrics they choose. (c) 2024 The Author(s). Published by Elsevier Ltd on behalf of Sports Medicine Australia. This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/).
引用
收藏
页码:572 / 580
页数:9
相关论文
共 50 条
  • [31] New Protocol for Evaluating Maximum Inspiratory Pressure: Concurrent Validity and Test-Retest Reliability
    Lopez-de-Uralde-Villanueva, Ibai
    Fabero-Garrido, Raul
    de Rivera, Elena Alonso Rodriguez
    Santana, Rafael
    Gotera-Rivera, Carolina
    Peces-Barba, German
    del Corral, Tamara
    PHYSICAL THERAPY, 2024, 104 (11):
  • [32] The test-retest reliability and concurrent validity of the Subjective Complaints Questionnaire for low back pain
    Ford, Jon Joseph
    Story, Ian
    McMeeken, Joan
    MANUAL THERAPY, 2009, 14 (03) : 283 - 291
  • [33] TEST-RETEST RELIABILITY AND CONCURRENT VALIDITY OF ATHLETIC PERFORMANCE COMBINE TESTS IN 6-15-YEAR-OLD MALE ATHLETES
    Gillen, Zachary M.
    Miramonti, Amelia A.
    McKay, Brianna D.
    Leutzinger, Todd J.
    Cramer, Joel T.
    JOURNAL OF STRENGTH AND CONDITIONING RESEARCH, 2018, 32 (10) : 2783 - 2794
  • [34] Shuttle walking test in obese women: test-retest reliability and concurrent validity with peak oxygen uptake
    Juergensen, Soraia P.
    Trimer, Renata
    Dourado, Victor Z.
    Di Thommazo-Luporini, Luciana
    Bonjorno-Junior, Jose C.
    Oliveira, Claudio R.
    Arena, Ross
    Mendes, Renata G.
    Borghi-Silva, Audrey
    CLINICAL PHYSIOLOGY AND FUNCTIONAL IMAGING, 2015, 35 (02) : 120 - 126
  • [35] Test-retest reliability, concurrent validity and correlates of the two-minute walk test in outpatients with psychosis
    Vancampfort, Davy
    Kimbowa, Samuel
    Basangwa, David
    Smith, Lee
    Stubbs, Brendon
    Van Damme, Tine
    De Hert, Marc
    Mugisha, James
    PSYCHIATRY RESEARCH, 2019, 282
  • [36] Concurrent Validity and Test-Retest Reliability of the 3-Meter Backward Walk Test in Stroke Survivors
    Kapan, Ali
    Ristic, Milos
    Yang, Lin
    Kranz, Gottfried
    Waldhoer, Thomas
    HEALTHCARE, 2023, 11 (23)
  • [37] Test-retest Reliability Of A Computerized Balance Assessment On Static And Dynamic Balance In Older Adults
    Narita, Makoto
    Koizumi, Daisuke
    Takeshima, Nobuo
    Rogers, Nicole L.
    Rogers, Michael E.
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2011, 43 (05): : 711 - 711
  • [38] Development of an Agility Test for Badminton Players and Assessment of Its Validity and Test-Retest Reliability
    Bahia Loureiro, Luiz de Franca, Jr.
    de Freitas, Paulo Barbosa
    INTERNATIONAL JOURNAL OF SPORTS PHYSIOLOGY AND PERFORMANCE, 2016, 11 (03) : 305 - 310
  • [39] Test-retest-reliability and validity of the kinesiology muscle test
    Lüdtke, R
    Kunz, B
    Seeber, N
    Ring, J
    COMPLEMENTARY THERAPIES IN MEDICINE, 2001, 9 (03) : 141 - 145
  • [40] TEST RETEST RELIABILITY OF PSYCHOPHYSIOLOGICAL ASSESSMENT
    WATERS, WF
    WILLIAMSON, DA
    BERNARD, BA
    BLOUIN, DC
    FAULSTICH, ME
    BEHAVIOUR RESEARCH AND THERAPY, 1987, 25 (03) : 213 - 221