摘要
For spacecraft with high power consumption, it is reasonable to build the thermal control system based on a two-phase mechanically pumped loop. The heat-controlled accumulator is a key element of the two-phase mechanically pumped loop, which allows for the control of pressure in the loop and maintains the required level of coolant boiling temperature or cavitation margin at the pump inlet. There can be two critical modes of loop operation where the ability to control pressure will be lost. The first critical mode occurs when the accumulator fills with liquid at high heat loads. The second critical mode occurs when the accumulator is at low heat loads and partial loss of coolant, for example, due to the leak caused by micrometeorite breakdown. Both modes are caused by insufficient accumulator volume or working fluid charge. To analyze the loop characteristics in critical modes, experiments were conducted on a test bench with ammonia coolant, and a mathematical simulation of a two-phase mechanically pumped loop was performed. The results show that the loop can operate in critical modes in a certain range of heat loads. The conducted studies allow for the design of a heat-controlled accumulator with the minimum required volume, expand the performance range of a two-phase mechanically pumped loop, and increase the reliability of its operation in orbit during long-term missions.
引用
收藏
页码:123 / 130
页数:8
相关论文
共 50 条
  • [31] The two-phase specific heat at constant volume of propane in the critical region
    Abdulagatov, IM
    Levina, LN
    Zakaryaev, ZR
    Mamchenkova, ON
    FLUID PHASE EQUILIBRIA, 1997, 127 (1-2) : 205 - 236
  • [32] Two-phase convection in a porous medium with nonuniform volume heat release
    V. V. Likhanskii
    A. I. Loboiko
    O. V. Khoruzhii
    Atomic Energy, 1997, 82 : 180 - 186
  • [33] Design of Control Systems for Two-Phase Microfluidic Processes
    Cairone, F.
    Bucolo, M.
    2016 24TH MEDITERRANEAN CONFERENCE ON CONTROL AND AUTOMATION (MED), 2016, : 973 - 978
  • [34] Two-Phase Flow Heat Transfer in Nuclear Reactor Systems
    Koncar, Bostjan
    Krepper, Eckhard
    Bestion, Dominique
    Song, Chul-Hwa
    Hassan, Yassin A.
    SCIENCE AND TECHNOLOGY OF NUCLEAR INSTALLATIONS, 2013, 2013
  • [35] Heat Transfer Enhancement in Two-Phase Systems with Capillary Pumps
    Kiseev, V. M.
    Sazhin, O., V
    TECHNICAL PHYSICS, 2022, 67 (02) : 136 - 145
  • [36] Heat conduction and porosity correction for diverse two-phase systems
    1600, Institute of Physics Publishing Ltd, Bristol, Engl (28):
  • [37] Heat Transfer Enhancement in Two-Phase Systems with Capillary Pumps
    V. M. Kiseev
    O. V. Sazhin
    Technical Physics, 2022, 67 : 136 - 145
  • [38] Heat capacity of two-phase systems according to the law of additivity
    Dadash-zade, Mirza A.
    Aliyev, Inglab N.
    Mammadova, Gulbahar G.
    NAFTA-GAZ, 2024, (12):
  • [39] Effective heat storage coefficient of two-phase isotropic systems
    Jagjiwanram
    Singh, R
    INDIAN JOURNAL OF PURE & APPLIED PHYSICS, 2004, 42 (04) : 283 - 287
  • [40] Development and study of two-phase pumpless heat transfer systems
    Sasin, V.Ya.
    Borodkin, A.A.
    Bolotin, E.M.
    Hoa, Le Suan
    Fantozzi, F.
    Heat Transfer Research, 2001, 32 (4-6) : 309 - 316