Composite floor slab effect on seismic performance of steel-framed-tube structures with shear links

被引:1
|
作者
Lian, Ming [1 ,2 ]
Luo, Ziqi [1 ]
Su, Mingzhou [1 ,2 ]
Zhang, Hao [1 ,2 ]
Shen, Hongxia [1 ,2 ]
机构
[1] Xian Univ Architecture & Technol, Sch Civil Engn, Xian 710055, Peoples R China
[2] Minist Educ XAUAT, Key Lab Struct Engn & Earthquake Resistance, Xian 710055, Peoples R China
基金
中国国家自然科学基金;
关键词
Steel framed-tube structure; Low-yield-point shear link; RC slab; Seismic behavior; Pushover analysis; Time-history analysis; DESIGN; BEAM;
D O I
10.1016/j.soildyn.2024.108800
中图分类号
P5 [地质学];
学科分类号
0709 ; 081803 ;
摘要
High-strength steel-framed-tube structures with low-yield-point shear links (SFT-RLYPSL) exhibit exceptional lateral and torsional stiffness, coupled with significant energy dissipation capacities. This study aims to investigate teh influence of composite floor slabs on the seismic performance of these structures. Expanding on previous research concerning SFT-RLYPSL, this paper presents a simplified numerical model for the SFT-RLYPSL, incorporating the influence of the composite floor slab. The developed model employs the steel4 constitutive relation to accurately depict the behavior of low-yield-point steel. Furthermore, the simplified numerical model utilizes two-node link elements to simulate shear links and integrates composite beams to represent the influence of the composite floor slab. Using this simplified model, elastic-plastic pushover analysis is performed on five distinct SFT-RLYPSL structural cases, and nonlinear time-history analysis is conducted on three structural configurations. The investigation explores various aspects of the seismic performance of SFT-RLYPSL, including modal behavior, pushover curves, progression of overturning failure, time-history roof displacements, inter-story drift angles, base reactions, inter-story shear, failure modes, residual inter-story drift angles, and the manifestation of shear lag phenomena. The findings suggest that incorporating the composite floor slab effect enhances initial stiffness and peak load capacity in pushover analysis, leading to distinct three-stage pushover curves. During nonlinear time-history analysis, the composite floor slab effect increases structural stiffness, decreases roof displacements and inter-story drift angles, while simultaneously increasing base reactions, worsening component damage, and raising collapse risk. Nevertheless, its influence on residual inter-story drift angles remains relatively minor, with a mitigating effect on the shear lag phenomenon. Importantly, the degree of this impact varies with alterations in floor slab thickness and seismic intensity, highlighting the critical importance of considering the composite floor slab effect in structural design deliberations.
引用
收藏
页数:20
相关论文
共 50 条
  • [31] Research on seismic performance of precast steel-concrete composite tube shear walls with horizontal joint
    Dang, Longji
    Pang, Rui
    Liu, Yuhao
    Wang, Yixiao
    Wang, Lu
    Yang, Jian
    ENGINEERING STRUCTURES, 2022, 250
  • [32] Seismic performance of floor-by-floor assembled steel braced structures with stiffened connections
    Wang, W. (weiwang@tongji.edu.cn), 1600, Taylor and Francis Ltd. (06):
  • [33] Experimental and finite element study of high-strength steel framed-tube structures with replaceable shear links under cyclic loading
    Cheng, Qianqian
    Lian, Ming
    Su, Mingzhou
    Zhang, Hao
    STRUCTURES, 2021, 29 : 48 - 64
  • [34] Seismic performance of cold-formed steel framed shear walls with steel sheathing and gypsum board
    Feng, Ruo-qiang
    Zhu, Baochen
    Xu, PengHui
    Qiu, Yun
    THIN-WALLED STRUCTURES, 2019, 143
  • [35] Seismic Demand on Shear Panel Dampers Installed in Steel-Framed Bridge Pier Structures
    Ge, Hanbin
    Chen, Xi
    Matsui, Nobuyuki
    JOURNAL OF EARTHQUAKE ENGINEERING, 2011, 15 (03) : 339 - 361
  • [36] Numerical study of the seismic behavior of steel frame-tube structures with bolted web-connected replaceable shear links
    Lian, Ming
    Cheng, Qianqian
    Zhang, Hao
    Su, Mingzhou
    STEEL AND COMPOSITE STRUCTURES, 2020, 35 (03): : 305 - 325
  • [37] Seismic performance upgrading of steel structures with shear panel dampers
    Ge, Hanbin
    Chen, Zhi-Yi
    Advances in Structural Engineering:Theory and Applications Vols 1 and 2, 2006, : 99 - 106
  • [38] Cyclic loading behavior of high-strength steel framed-tube structures with replaceable shear links constructed using Q355 structural steel
    Guo, Yan
    Lian, Ming
    Zhang, Hao
    Cheng, Qianqian
    STEEL AND COMPOSITE STRUCTURES, 2022, 42 (06): : 827 - 841
  • [39] Shear Performance and Optimization Design of Beam-Slab Connector of Prefabricated Steel-Concrete Composite Structures
    Ma, Shaochun
    Chen, Long
    Bao, Peng
    Wang, Dongtao
    INTERNATIONAL JOURNAL OF CIVIL ENGINEERING, 2022, 20 (11) : 1277 - 1290
  • [40] Study on Effect of Comfort of Composite Tube Truss Floor in Different Sizes of the Concrete Slab
    Han, Xin
    Wang, Yi
    Zhao, Xue-Li
    PROCEEDINGS OF THE 2014 INTERNATIONAL CONFERENCE ON MECHANICS AND CIVIL ENGINEERING, 2014, 7 : 822 - 825