An integrated experimental and CFD analysis of ceiling-fan-integrated air conditioning system: Indoor air quality and air velocity

被引:3
|
作者
Li, Lu [1 ,2 ]
He, Yingdong [2 ,3 ]
Chen, Wenhua [4 ]
Ji, Yunzhu [2 ,5 ]
Fung, Jimmy C. H. [6 ,7 ]
Lau, Alexis K. H. [6 ,8 ]
机构
[1] Syracuse Univ, Dept Mech & Aerosp Engn, Syracuse, NY 13244 USA
[2] Univ Calif Berkeley, Ctr Built Environm, Berkeley, CA USA
[3] Hunan Univ, Coll Civil Engn, Changsha, Peoples R China
[4] Nanchang Univ, Sch Infrastruct Engn, Nanchang, Peoples R China
[5] Southeast Univ, Sch Architecture, Nanjing, Peoples R China
[6] Hong Kong Univ Sci & Technol, Div Environm & Sustainabil, Clear Water Bay, Hong Kong, Peoples R China
[7] Hong Kong Univ Sci & Technol, Dept Math, Clear Water Bay, Hong Kong, Peoples R China
[8] Hong Kong Univ Sci & Technol, Dept Civil & Environm Engn, Clear Water Bay, Hong Kong, Peoples R China
关键词
Ceiling fan; Indoor air quality; Air velocity; Age; -of; -air; Health exposure; THERMAL COMFORT ENHANCEMENT; AGE; VENTILATION; BUILDINGS; SPEEDS;
D O I
10.1016/j.buildenv.2024.111633
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The Ceiling-Fan-Integrated-Air Conditioning (CFIAC) represents an innovative HVAC design, which involves directing supply air towards the vicinity of ceiling fans, facilitating the mixture and distribution of air within a room. By eliminating the need for terminal ductwork and diffusers, CFIAC offers an efficient cooling solution for occupants. This study employs experimental and CFD methodologies to assess various parameters, including airflow, air pollution, and temperature related to this system. Experimental tests were conducted in a controlled chamber, with the lowest inlet air velocity and the temperature, where supply air was projected from a highsidewall vent directly towards a ceiling fan's centerline. Different operational conditions of the ceiling fan were examined (off, Level 2 and Level 4 downwards, and Upwards). Carbon dioxide (CO2), employed as a tracer gas, was released near a thermal manikin at three distinct locations within the chamber: the middle, lower left, and upper right, and the corresponding CO2 concentration distributions were evaluated. Additionally, air velocity measurements were collected and analyzed. The effectiveness of ventilation and potential health exposure was quantified using the age of air and intake fraction (IF) metrics. The findings indicate that operating the fan at Level 4 with downward airflow enhances air velocities and heat loss while reducing CO2 concentrations and age of air by an average of 14 % and 4 min, respectively. Moreover, the IF values for Level 4 operations, both downward and upward, were marginally lower compared to those recorded for Level 2 downward and fan-off scenarios, suggesting a decreased risk of cross-infection.
引用
收藏
页数:18
相关论文
共 50 条
  • [31] Experimental and CFD modelling of an ejector system for vehicle air conditioning
    Riffat, SB
    Everitt, P
    JOURNAL OF THE INSTITUTE OF ENERGY, 1999, 72 (491): : 41 - 47
  • [32] Empirical analysis of indoor air quality enhancement potential in a liquid-desiccant assisted air conditioning system
    Park, Joon-Young
    Yoon, Dong-Seob
    Li, Shiying
    Park, Junseok
    Bang, Jong-Il
    Sung, Minki
    Jeong, Jae-Weon
    BUILDING AND ENVIRONMENT, 2017, 121 : 11 - 25
  • [33] An integrated forecasting system for air quality control
    Carnevale, Claudio
    De Angelis, Elena
    Finzi, Giovanna
    Turrini, Enrico
    Volta, Marialuisa
    2019 18TH EUROPEAN CONTROL CONFERENCE (ECC), 2019, : 830 - 835
  • [34] Integrated Photocatalytic Filtration Array for Indoor Air Quality Control
    Denny, Frans
    Permana, Eric
    Scott, Jason
    Wang, Jing
    Pui, David Y. H.
    Amal, Rose
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2010, 44 (14) : 5558 - 5563
  • [35] Improving Indoor Air Ventilation by a Ceiling Fan to Mitigate Aerosols Transmission
    Santosh Ramagya Mallah
    Sachidananda Behera
    Atul Sharma
    Amit Agrawal
    Rajneesh Bhardwaj
    Transactions of the Indian National Academy of Engineering, 2023, 8 (1) : 171 - 182
  • [36] Influence of water contamination in air-conditioning system on indoor air quality and proviting measures
    Zheng, AP
    ISHVAC 99: 3RD INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATION AND AIR CONDITIONING, VOLS 1 AND 2, 1999, : 220 - 225
  • [37] CFD analysis on indoor climate and air quality in operation theatres
    Yu, B
    Luscuere, PG
    BUILT ENVIRONMENT AND PUBLIC HEALTH, PROCEEDINGS, 2004, : 397 - 397
  • [38] Experimental and statistical analysis of indoor air quality characteristics in an air conditioned car
    Thirumal, P.
    Amirthagadeswaran, K.S.
    Jayabal, S.
    Nature Environment and Pollution Technology, 2014, 13 (01) : 11 - 18
  • [39] An experimental analysis of automotive air conditioning system
    Kaynakli, Ö
    Horuz, I
    INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2003, 30 (02) : 273 - 284
  • [40] A field study on indoor environmental quality and energy savings of an office building integrated with underfloor air conditioning system in India
    Lakshmanan, Ramesh Krishnan
    Lachireddi, Gangadhara Kiran Kumar
    SCIENCE AND TECHNOLOGY FOR THE BUILT ENVIRONMENT, 2023, 29 (02) : 109 - 130