Report Diabetic Ketoacidosis in a Patient With Type I Diabetes Treated With a Closed-Loop Sensor-Augmented Insulin Infusion System

被引:4
|
作者
Sharma, Pranjali P. [1 ]
-Berlioz, Ana M. Ramirez
Weisz, Angela D. [2 ]
机构
[1] Parkview Hlth Syst, Dept Endocrinol, 4722 Eagleridge Circle, Pueblo, CO 81008 USA
[2] Parkview Hlth Syst, Pueblo, CO USA
来源
AACE CLINICAL CASE REPORTS | 2023年 / 9卷 / 04期
关键词
DKA; type 1 diabetes mellitus; diabetes technology; closed -loop insulin infusion system; tirzepatide;
D O I
10.1016/j.aace.2023.04.010
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background/Objective: Closed-loop insulin infusion systems (CLSs) such as Tandem t:slim with Control-IQ (t:slim CIQ) improve glycemic control and decrease diabetic ketoacidosis (DKA) risk in type 1 diabetes mellitus (T1DM). We report a case of CLS failure, likely from tirzepatide-induced volume depletion, leading to DKA. Case Report: A 36-year-old woman with T1DM on t:slim CIQ CLS was prescribed tirzepatide for weight loss. Three months later, 4 days after the last tirzepatide injection, she presented with worsening nausea, vomiting, 50-lbs weight loss, minimal oral intake for 3 days, and positive urine ketone result. Her heart rate was 137 beats/min and respiratory rate was 35 breaths/min, and she had Kussmaul breathing, with dry oral mucosa indicating volume depletion. Laboratory examination showed a fingerstick glucose level of 289 mg/dL, serum glucose level of 322 mg/dL, bicarbonate level of 12 mmol/L, and anion gap of 21 mmol/L confirming high-anion-gap metabolic acidosis, suggesting DKA. A concurrent continuous glucose monitor (CGM) reading was 40 mg/dL. The CLS and CGM were removed. DKA resolved within 72 hours (serum glucose level of 143 mg/dL, anion gap of 8 mmol/L, bicarbonate level of 24 mmol/L) on intravenous insulin and fluids. The CLS and CGM were restarted with good glycemic control. Tirzepatide was discontinued to avoid future episodes of volume depletion. Discussion: Volume depletion affects interstitial fluid glucose levels due to compensatory mechanisms. This may result in CLS failure due to CGM dependence on interstitial glucose measurements, precipitating DKA. Conclusion: Patients on CLS therapy should be cautioned against CLS failure in volume-depleted states with interstitial glucose-level changes. A back-up plan with multiple daily insulin injections should be discussed. (c) 2023 AACE. Published by Elsevier Inc. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
引用
收藏
页码:116 / 121
页数:6
相关论文
共 50 条
  • [21] SLEEP IN CAREGIVERS OF VERY YOUNG CHILDREN WITH TYPE 1 DIABETES USING A SENSOR AUGMENTED PUMP OR CLOSED-LOOP INSULIN DELIVERY
    Madrid-Valero, J.
    Gregory, A.
    Ware, J.
    Allen, J.
    Boughton, C.
    Hartnell, S.
    Wilinska, M.
    Thankamony, A.
    De Beaufort, C.
    Schierloh, U.
    Campbell, F.
    Sibayan, J.
    Bocchino, L.
    Kollman, C.
    Hovorka, R.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2022, 24 : A210 - A211
  • [22] A PERSPECTIVE OF SENSOR-AUGMENTED INSULIN PUMP THERAPY IN THE TREATMENT OF TYPE 1 DIABETES
    Rayfield, Elliot J.
    ENDOCRINE PRACTICE, 2015, 21 (01) : 91 - 92
  • [23] Successful treatment of diabetic ketoacidosis secondary to fulminant type 1 diabetes mellitus using a closed-loop artificial pancreas in a pediatric patient
    Tamura, Takahiko
    Tadokoro, Tsukasa
    Iwata, Hideki
    Namikawa, Tsutomu
    Hanazaki, Kazuhiro
    Kawano, Takashi
    JOURNAL OF ARTIFICIAL ORGANS, 2024, 27 (01) : 73 - 76
  • [24] Sensor-Augmented Insulin-Pump Therapy in Type 1 Diabetes REPLY
    Bergenstal, Richard M.
    NEW ENGLAND JOURNAL OF MEDICINE, 2010, 363 (21): : 2071 - 2071
  • [25] Successful treatment of diabetic ketoacidosis secondary to fulminant type 1 diabetes mellitus using a closed-loop artificial pancreas in a pediatric patient
    Takahiko Tamura
    Tsukasa Tadokoro
    Hideki Iwata
    Tsutomu Namikawa
    Kazuhiro Hanazaki
    Takashi Kawano
    Journal of Artificial Organs, 2024, 27 : 73 - 76
  • [26] Effectiveness of Sensor-Augmented Insulin-Pump Therapy in Type 1 Diabetes
    Bergenstal, Richard M.
    Tamborlane, William V.
    Ahmann, Andrew
    Buse, John B.
    Dailey, George
    Davis, Stephen N.
    Joyce, Carol
    Peoples, Tim
    Perkins, Bruce A.
    Welsh, John B.
    Willi, Steven M.
    Wood, Michael A.
    NEW ENGLAND JOURNAL OF MEDICINE, 2010, 363 (04): : 311 - 320
  • [27] Effectiveness of sensor-augmented insulin-pump therapy in type 1 diabetes
    Jecht, M.
    DIABETOLOGE, 2010, 6 (06): : 486 - 487
  • [28] Randomized Trial of Assisted Hybrid Closed-Loop Therapy Versus Sensor-Augmented Pump Therapy in Pregnancy
    Polsky, Sarit
    Buschur, Elizabeth
    Dungan, Kathleen
    Garcetti, Rachel
    Nease, Emily
    Malecha, Emily
    Bartholomew, Anna
    Johnson, Carly
    Pyle, Laura
    Snell-Bergeon, Janet
    DIABETES TECHNOLOGY & THERAPEUTICS, 2024, 26 (08) : 547 - 555
  • [29] Closed-loop insulin delivery for treatment of type 1 diabetes
    Daniela Elleri
    David B Dunger
    Roman Hovorka
    BMC Medicine, 9
  • [30] Closed-Loop Insulin Delivery for Outpatients With Type 2 Diabetes
    Slomski, Anita
    JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2021, 326 (12): : 1139 - 1139