Methodology exploration and reproducibility evaluation of TAI and TSI for quantitative ultrasound assessment of hepatic steatosis

被引:1
|
作者
Li, Xiao [1 ]
Sun, Ziwei [1 ]
Liu, Wei [1 ]
Sun, Lianjie [2 ]
Ren, Junyi [1 ]
Xu, Ying [1 ]
Yu, Haoyong [3 ,5 ]
Bai, Wenkun [4 ]
机构
[1] Shanghai Jiao Tong Univ, Shanghai Peoples Hosp 6, Dept Ultrasound Med, Sch Med, Shanghai, Peoples R China
[2] Qingdao Univ, Qingdao, Peoples R China
[3] Shanghai Jiao Tong Univ, Shanghai Peoples Hosp 6, Inst Shanghai Diabet, Dept Endocrinol & Metab,Sch Med, Shanghai, Peoples R China
[4] Tongji Univ, Tongji Hosp, Shanghai Inst Ultrasound Med, Dept Ultrasound Med, Shanghai, Peoples R China
[5] Shanghai Jiao Tong Univ, Dept Endocrinol & Metab, Shanghai Peoples Hosp 6, Sch Med, Yishan Rd 600, Shanghai 200233, Peoples R China
关键词
Metabolic dysfunction-associated steatotic liver; disease; Quantitative ultrasound; Controlled attenuation parameter; Tissue attenuation imaging; Tissue scatter distribution imaging; CONTROLLED ATTENUATION PARAMETER; FATTY LIVER-DISEASE; STIFFNESS; FIBROSIS; NAFLD;
D O I
10.1016/j.heliyon.2024.e31904
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Background and aim: New quantitative ultrasound techniques can be used to quantify hepatic steatosis, including tissue attenuation imaging (TAI), tissue scatter -distribution imaging (TSI), and the hepatorenal index (HRI). However, the measurement norms and the effects of fasting on these measurements remain unclear. The present study performed a methodological exploration and investigated the reliability of these measurements. Methods: In total, 103 participants were prospectively recruited for ultrasonography and magnetic resonance imaging (MRI) scans. For the TAI and TSI data, the upper (2 cm), middle (4 cm) and lower (6 cm) areas determined according to the depth of the region of interest from the liver capsule, were sampled three times. Correlation analyses were performed to compare the measurements of TAI, TSI, and HRI with the controlled attenuation parameter (CAP) or MRI-proton density fat fraction (MRI-PDFF). Intra- and inter-operator repeatability was assessed using intraclass correlation coefficients. The effects of fasting on these measurements were then compared.<br /> Results: The TAI and TSI measurements obtained from the upper and middle depths exhibited stronger correlations with the CAP measurements than those obtained from the lower depth. Specifically, the mean TAI had a significant positive correlation with MRI-PDFF (r = 0.753, P < 0.0001). TAI and TSI measurements exhibited excellent intra- (0.933 and 0.925, respectively) and inter- (0.896 and 0.766, respectively) examiner reliability. However, the correlation between HRI and CAP measurements was only 0.281, with no significant correlation with MRI-PDFF, and intraand inter-examiner reproducibility of 0.458 and 0.343, respectively. Fasting did not affect these measurements. Conclusions: TAI , TSI measurements demonstrated good intra- and interobserver reliability and correlated well with CAP and MRI-PDFF measurements. However, in practice -based clinical applications, the sampling depth should be controlled within 2 -4 cm of the hepatic capsule; no fasting is required before the examination.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Quantitative Ultrasound Assessment of Hepatic Steatosis
    Kaliaev, Artem
    Chavez, Wilson
    Soto, Jorge
    Huda, Fahimul
    Xie, Hua
    Nguyen, Man
    Shamdasani, Vijay
    Anderson, Stephan
    JOURNAL OF CLINICAL AND EXPERIMENTAL HEPATOLOGY, 2022, 12 (04) : 1091 - 1101
  • [2] Ultraportable Quantitative Ultrasound for Hepatic Steatosis Assessment
    Heriard-Dubreuil, Baptiste
    Besson, Adrien
    Mamou, Jonathan
    Gay, Joel
    Foucher, Juliette
    De Ledinghen, Victor
    Cohen-Bacrie, Claude
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2024, 50 (12): : 1842 - 1848
  • [3] Reproducibility of ultrasound attenuation imaging for the noninvasive evaluation of hepatic steatosis
    Yoo, Jeongin
    Lee, Jeong Min
    Joo, Ijin
    Lee, Dong Ho
    Yoon, Jeong Hee
    Kang, Hyo-Jin
    Ahn, Su Joa
    ULTRASONOGRAPHY, 2020, 39 (02) : 121 - 129
  • [4] Interoperator reproducibility of quantitative ultrasound analysis of hepatic steatosis in participants with suspected MASLD: A prospective study
    Yin, Haohao
    Xiong, Bing
    Yu, Jifeng
    Fan, Yunling
    Zhou, Boyang
    Sun, Yikang
    Wang, Lifan
    Xu, Huixiong
    Zhu, Yuli
    EUROPEAN JOURNAL OF RADIOLOGY, 2024, 175
  • [5] Reproducibility of ultrasound-guided attenuation parameter (UGAP) to the noninvasive evaluation of hepatic steatosis
    Yanan Zhao
    Minyue Jia
    Chao Zhang
    Xinxu Feng
    Jifan Chen
    Qunying Li
    Yingying Zhang
    Wen Xu
    Yiping Dong
    Yifan Jiang
    Yajing Liu
    Pintong Huang
    Scientific Reports, 12
  • [6] Reproducibility of ultrasound-guided attenuation parameter (UGAP) to the noninvasive evaluation of hepatic steatosis
    Zhao, Yanan
    Jia, Minyue
    Zhang, Chao
    Feng, Xinxu
    Chen, Jifan
    Li, Qunying
    Zhang, Yingying
    Xu, Wen
    Dong, Yiping
    Liu, Yajing
    Jiang, Yifan
    Huang, Pintong
    SCIENTIFIC REPORTS, 2022, 12 (01)
  • [7] Improved Assessment of Hepatic Steatosis in Humans Using Multi-Parametric Quantitative Ultrasound
    Han, Aiguo
    Boehringer, Andrew S.
    Zhang, Yingzhen N.
    Montes, Vivian
    Andre, Michael P.
    Erdman, John W., Jr.
    Loomba, Rohit
    Sirlin, Claude B.
    O'Brien, William D., Jr.
    2019 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2019, : 1819 - 1822
  • [8] Ultrasound attenuation imaging: a reproducible alternative for the noninvasive quantitative assessment of hepatic steatosis in children
    Dardanelli, Esteban P.
    Orozco, Maria Eugenia
    Oliva, Vanesa
    Lutereau, Juan Francisco
    Ferrari, Facundo Agustin
    Bravo, Monica G.
    Ruvinsky, Silvina
    Roel, Macarena
    Barvosa, Pablo C.
    Armeno, Marisa
    Kaplan, Julio S.
    PEDIATRIC RADIOLOGY, 2023, 53 (08) : 1618 - 1628
  • [9] Ultrasound attenuation imaging: a reproducible alternative for the noninvasive quantitative assessment of hepatic steatosis in children
    Esteban P. Dardanelli
    María Eugenia Orozco
    Vanesa Oliva
    Juan Francisco Lutereau
    Facundo Agustín Ferrari
    Mónica G. Bravo
    Silvina Ruvinsky
    Macarena Roel
    Pablo C. Barvosa
    Marisa Armeno
    Julio S. Kaplan
    Pediatric Radiology, 2023, 53 : 1618 - 1628
  • [10] Utility of quantitative ultrasound in community screening for hepatic steatosis
    Chang, Tu-Yung
    Chang, Shu-Hung
    Lin, Ying-Hsiu
    Ho, Wen-Chao
    Wang, Chiao-Yin
    Jeng, Wen-Juei
    Wan, Yung-Liang
    Tsui, Po-Hsiang
    ULTRASONICS, 2021, 111