Longitudinal Stent Deformation Caused by Retraction of the Looped Main Branch Guidewire

被引:0
|
作者
Lee, Hung-Hao [1 ]
Hsu, Po-Chao [1 ,3 ]
Lee, Wen-Hsien [1 ,2 ,3 ]
Chu, Chun-Yuan [1 ]
Su, Ho-Ming [1 ,2 ,3 ]
Lin, Tsung-Hsien [1 ,3 ]
Voon, Wen-Chol [1 ,3 ]
Lai, Wen-Ter [1 ,3 ]
Sheu, Sheng-Hsiung [1 ,3 ]
Chiu, Cheng-An [1 ]
机构
[1] Kaohsiung Med Univ Hosp, Dept Internal Med, Div Cardiol, 100,Tzyou 1st Rd, Kaohsiung 80708, Taiwan
[2] Kaohsiung Municipal Hsiaokang Hosp, Dept Internal Med, Kaohsiung, Taiwan
[3] Kaohsiung Med Univ, Coll Med, Fac Med, Dept Internal Med, Kaohsiung, Taiwan
关键词
Complications; Percutaneous coronary intervention; Stent fracture;
D O I
10.6515/ACS20151115A
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
A 66-year-old male was treated percutaneously for a bifurcation lesion of the left anterior descending coronary artery by provisional stenting using the jailed wire technique. After successfully stenting the main branch, retraction of the looped main branch guidewire was impossible. After using an intravascular ultrasound we discovered the guidewire was entangled with a stent strut. Thereafter, the proximal stent elongated after retraction. With the support of an over-the-wire microcatheter, we finally pulled out the entrapped guidewire. This rare complication should remind physicians that it is important to prevent the distal guidewire from being looped while retracting it through a stent, regardless of whether it is in the side branch or main vessel. If the guidewire becomes entangled with a stent, a microcatheter or low-profile balloon can be advanced to rescue it before the stent is damaged. Furthermore, the microcather should be maintained after successful retraction of the entangled guidewire to facilitate further wiring and subsequent rescue angioplasty as necessary.
引用
收藏
页码:616 / 618
页数:3
相关论文
共 50 条
  • [1] Longitudinal Deformation of Distal Edge in a New-Generation Stent Caused by Guidewire Entrapment
    Taleb, Adam
    Parikh, Gaurav
    Kakouros, Nikolaos
    TEXAS HEART INSTITUTE JOURNAL, 2018, 45 (01): : 45 - 47
  • [2] Distal longitudinal deformation of a Synergy stent by jailed Rotawire guidewire
    Leong, A. M.
    Ong, P. J. L.
    Ho, H. H.
    Watson, T.
    HERZ, 2017, 42 (02) : 209 - 210
  • [3] Longitudinal stent elongation during retraction of entrapped jailed guidewire in a side branch with balloon catheter support: a case report
    Taniguchi, Norimasa
    Mizuguchi, Yukio
    Takahashi, Akihiko
    CARDIOVASCULAR REVASCULARIZATION MEDICINE, 2015, 16 (01) : 52 - 54
  • [4] Longitudinal Stent Elongation from 'LAD' to 'LMCA' During Retraction of Entrapped Jailed Guidewire from Diagonal Side Branch
    Mandal, Praskas Chandra
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2016, 67 (16) : S231 - S232
  • [5] Accordion Stent Deformation upon Retrieval of a Side-Branch Protective Guidewire
    Cheng, Shih-Tsung
    Su, Cheng-Wen
    Liau, Chiau-Suong
    Ko, Yu-Lin
    ACTA CARDIOLOGICA SINICA, 2015, 31 (06) : 568 - 571
  • [6] Longitudinal stent deformation elongating to left main trunk
    Matsushita K.
    Arakawa K.
    Hibi K.
    Kimura K.
    Umemura S.
    Himeno H.
    Cardiovascular Intervention and Therapeutics, 2014, 29 (3) : 247 - 251
  • [7] ACCORDION-LIKE STENT DEFORMATION CAUSED BY ENTRAPPED GUIDEWIRE: A CASE REPORT
    Cankovic, Milenko
    Todic, Vanja Drljevic
    Petrovic, Milovan
    Ivanovic, Vladimir
    kovacevic, Mila
    Milovancev, Aleksandra
    Bjelobrk, Marija
    Miljkovic, Tatjana
    Todic, Mirko
    ACTA MEDICA MEDITERRANEA, 2023, 39 (02): : 357 - 360
  • [8] It's a Trap: A Case of Strangulated Coronary Guidewire and Longitudinal Stent Deformation in the Right Coronary Artery
    Rehman, Adeel Ur
    Malik, Jahanzeb
    Iftikhar, Imran
    Javed, Asim
    Jalal, Anjum
    Satti, Khawar
    AMERICAN JOURNAL OF CASE REPORTS, 2021, 22
  • [9] Longitudinal Stent Deformation at the Proximal Segment of the Left Main Coronary Artery Caused by a Stuck OCT Catheter: Case Report and Review of Literature
    Zhang, Ming
    Pan, Xietian
    Wang, Yabin
    Yin, Shuo
    Bai, Peng
    Gao, Lei
    REVIEWS IN CARDIOVASCULAR MEDICINE, 2024, 25 (04)
  • [10] Longitudinal Stent Deformation Caused by Optical Coherence Tomography Pullback in Percutaneous Coronary Intervention
    Kao, Ting-Wei
    Huang, Chin-Chou
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2021, 77 (14) : S154 - S155