Safety and efficacy of custom foldable silicone artificial iris implantation: prospective compassionate-use case series

被引:19
|
作者
Bonnet, Clemence [1 ,2 ]
Miller, Kevin M. [1 ]
机构
[1] Univ Calif Los Angeles, David Geffen Sch Med, Stein Eye Inst, Dept Ophthalmol, Los Angeles, CA USA
[2] Paris Descartes Univ, Cochin Hosp, Opthalmole Paris, Paris, France
来源
关键词
D O I
10.1097/j.jcrs.0000000000000172
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To assess the preliminary safety and efficacy of custom silicone artificial iris implantation. Setting: Stein Eye Institute. Design: Prospective consecutive case series. Methods: Medical records of patients implanted with the artificial iris were reviewed and followed for 1 year. Safety measures included corrected distance visual acuity (CDVA), intraocular pressure (IOP), endothelial cell count (ECC), surgical complications, secondary interventions, and adverse events (AEs). Efficacy measures included CDVA with glare, subjective daytime and nighttime glare graded from 0 to 10 (very significant), and subjective cosmetic appearance graded from 0 to 10 (very satisfied). Results: Twenty eyes (19 patients) were implanted. Safety data were mixed. CDVA improved in 13 eyes and worsened in 6. ECC decreased from 1918 +/- 870 to 1405 +/- 705 cells/mm(2) (P = .02). Eight eyes experienced postoperative complications. There were 4 IOP elevations, 2 corneal decompensations, 1 case of cystoid macular edema, and 1 device dislocation. Four eyes underwent secondary surgical interventions including 2 AEs (1 glaucoma surgery and 1 device dislocation). Efficacy outcomes were excellent. CDVA with glare improved from 1.5 +/- 0.6 to 0.7 +/- 0.8 logarithm of the minimum angle of resolution (P <.01). Mean subjective daytime glare decreased from 8.9 +/- 1.8 to 2.7 +/- 2.6 (P <.01) and nighttime glare decreased from 7.9 +/- 1.8 to 2.5 +/- 2.7 (P <.01). Mean cosmesis improved from 2.2 +/- 1.6 to 8.8 +/- 2.1 (P <.01). Conclusions: Custom artificial iris implantation was moderately risky but very effective at reducing light and glare sensitivity and in improving ocular cosmesis.
引用
收藏
页码:893 / 901
页数:9
相关论文
共 49 条
  • [31] Stereoelectroencephalography Implantation Using Frameless Neuronavigation and Varioguide: Prospective Analysis of Accuracy and Safety in a Case Series of 11 Patients
    Joris, Vincent
    Ribeiro-Vaz, JoseGeraldo
    Finet, Patrice
    El Tahry, Riem
    Elkaim, Lior M.
    Raftopoulos, Christian
    Ferrao-Santos, Susana
    WORLD NEUROSURGERY, 2023, 174 : E62 - E71
  • [32] EFFICACY AND SAFETY OF TRIPLE-THERAPY WITH PEGINTERFERON-RIBAVIRIN, AND BOCEPREVIR AS COMPASSIONATE-USE IN SPANISH PATIENTS WITH HEPATITIS C GENOTYPE 1 WITH SEVERE FIBROSIS: INTERIM-ANALYSIS AT 12 WEEKS
    Calleja, J. L.
    Pascasio, J. M.
    Ruiz-Antoran, B.
    Larrubia, J. R.
    Gea, F.
    de la Revilla, J.
    Forns, X.
    Barcena, R.
    Romero-Gomez, M.
    Crespo, J.
    Sola, R.
    Fernandez, C.
    Fernandez, I.
    Buti, M.
    JOURNAL OF HEPATOLOGY, 2013, 58 : S326 - S327
  • [33] Long-term efficacy and safety profiles of iris-fixated foldable anterior chamber phakic intraocular lens implantation in eyes with more than 10 years of follow-up
    Papa-Vettorazzi, Mario R.
    Moura-Coelho, Nuno
    Manero, Felicidad
    Cruz-Rodriguez, Jose B.
    Elies, Daniel
    Guell, Jose L.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2022, 48 (09): : 987 - 992
  • [34] Comment on: Long-term efficacy and safety profiles of iris-fixated foldable anterior chamber phakic intraocular lens implantation in eyes with more than 10 years of follow-up
    Tello, Alejandro
    Galvis, Virgilio
    Berrospi, Ruben D.
    Nova, Dora Victoria
    Martinez, Luz C.
    Villamizar, Sylvia J.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2022, 48 (12): : 1480 - 1480
  • [35] The Efficacy and Safety of Transarterial Chemoembolization Plus Iodine 125 Seed Implantation in the Treatment of Hepatocellular Carcinoma With Oligometastases: A Case Series Reports
    Zhang, Weihua
    Wu, Linxia
    Chen, Lei
    Ren, Yanqiao
    Sun, Tao
    Sun, Bo
    Zhu, Licheng
    Liu, Yiming
    Zheng, Chuansheng
    FRONTIERS IN ONCOLOGY, 2022, 12
  • [36] Direct superior approach with standard instrumentation for total hip arthroplasty: safety and efficacy in a prospective 200-case series
    Tsiridis, Eleftherios
    Kenanidis, Eustathios
    Potoupnis, Michael
    Sayegh, Fares E.
    HIP INTERNATIONAL, 2020, 30 (05) : 552 - 558
  • [37] Safety, feasibility, and efficacy of placement of steroid-eluting bioabsorbable sinus implants in the office setting: a prospective case series
    Matheny, Keith E.
    Carter, Kenny B., Jr.
    Tseng, Ewen Y.
    Fong, Karen J.
    INTERNATIONAL FORUM OF ALLERGY & RHINOLOGY, 2014, 4 (10) : 808 - 815
  • [38] Efficacy and safety of intradetrusor onabotulinumtoxinA injection for managing paediatric non-neurogenic overactive bladder: A prospective case-series study
    El-Dakhakhny, Amr S.
    El-Karamany, Tarek M.
    El-Atrebi, Mohamed
    Gharib, Tarek
    ARAB JOURNAL OF UROLOGY, 2019, 17 (02) : 143 - 149
  • [39] Use of DDAVP as prophylaxis against postpartum hemorrhage in women with von Willebrand's disease: A case series demonstrating safety and efficacy
    Bjoring, A
    Baxi, L
    JOURNAL OF WOMENS HEALTH, 2004, 13 (07) : 845 - 847
  • [40] Safety and efficacy of vertebroplasty: Early results of a prospective one-year case series of osteoporosis patients in an academic high-volume center
    Diel, Peter
    Merky, Dominique
    Roeder, Christoph
    Popp, Albrecht
    Perler, Malgorzata
    Heini, Paul Ferdinand
    INDIAN JOURNAL OF ORTHOPAEDICS, 2009, 43 (03) : 228 - 233