Myocardial Perfusion Scintigraphy in the Prediction of the Existence of Hemodynamically Significant Coronary Artery Stenosis

被引:0
|
作者
Stevic, Milos [1 ,2 ]
Vlajkovic, Marina [1 ,2 ]
Velickovic, Filip [1 ,2 ]
Andjelkovic, Tamara [1 ,2 ]
Topic, Nina [2 ]
机构
[1] Univ Nis, Fac Med, Nish, Serbia
[2] Univ Clin Ctr Nis, Ctr Nucl Med, Nish, Serbia
关键词
myocardial perfusion scintigraphy; coronary disease; hemodynamics of coronary artery stenosis; anatomical significance of coronary stenosis; ASSOCIATION TASK-FORCE; PRACTICE GUIDELINES COMMITTEE; AMERICAN-COLLEGE; VIABLE MYOCARDIUM; HEART-RATE; DISEASE; ANGIOGRAPHY; DIAGNOSIS; EXERCISE; ANGINA;
D O I
10.5937/afmnai41-48301
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction/Aim. Anatomically insignificant stenosis of coronary arteries obtained on coronary angiography, in numerous cases can show hemodynamic significance and as such cause ischemic myocardial changes. The goal was to assess the diagnostic accuracy of myocardial perfusion scintigraphy (SPECT MPI) in the detection of hemodinamically significant coronary artery stenosis in patients with moderate risk for ischemia, without previously detected coronary disease. Patients and methodology. The study included 258 patients, of which 54% females and 46% males, with an average age of 59.0 +/- 10.1 years. SPECT MPI was done by a two-day protocol with 99 mTc-MIBI. The pathological finding was the existence of perfusion defects. The physical stress test was done by Bruce protocol. Coronary angiography (CA) was performed according to a standard protocol in patients with pathological SPECT MPI findings (n = 128). Anatomically significant coronary artery narrowing was > 70%. Stenoses from 30% to 69% were considered hemodynamically significant in patients with reversible perfusion defects on SPECT MPI. Results. The sensitivity (SE) of SPECT MPI was 89%, specificity (SP) 42%, positive predictive value (PPV) 86%, negative predictive value (NPV) 50%, and total diagnostic accuracy (ACC) was 74% when the results were compared with stenosis > 70%. By including stenosis from 30% to 69%, the obtained values of diagnostic indicators of SPECT MPI reliability were: SE 91%; SP 100%; PPV 100%; NPV 50% and ACC 91%. Conclusion. With CA only, it is not possible to prove the existence of hemodynamic significance of coronary artery stenoses from 30% to 69%, which represents a recruitment range for developing ischemia. SPECT MPI shows high SE, SP, PPV, and ACC in detecting the existence of left ventricular myocardium perfusion disorder in either stenosis of coronary arteries with or without anatomically significant value.
引用
收藏
页码:29 / 41
页数:13
相关论文
共 50 条
  • [41] Diagnosis of Functionally Significant Coronary Stenosis with Exercise CT Myocardial Perfusion Imaging
    Habis, Michel
    Ghostine, Said
    Rohnean, Adela
    Capderou, Andre
    Paul, Jean-Francois
    RADIOLOGY, 2015, 274 (03) : 684 - 692
  • [42] THE ACTION OF NIFEDIPINE ON MYOCARDIAL PERFUSION WITH FIXED CORONARY-ARTERY STENOSIS
    FU, W
    YONG, AC
    GANGELL, P
    ROBERTS, MS
    KILPATRICK, D
    JOURNAL OF MOLECULAR AND CELLULAR CARDIOLOGY, 1984, 16 (07) : R17 - R17
  • [43] Diagnostic performance of static single-scan stress perfusion cardiac computed tomography in detecting hemodynamically significant coronary artery stenosis: a comparison with combined invasive coronary angiography and cardiovascular magnetic resonance-myocardial perfusion imaging
    Song, Inyoung
    Yi, Jeong Geun
    Park, Jeong Hee
    Kim, Mi Young
    Shin, Je Kyoun
    Ko, Sung Min
    ACTA RADIOLOGICA, 2018, 59 (10) : 1184 - 1193
  • [44] MYOCARDIAL PERFUSION SCINTIGRAPHY DURING MAXIMAL CORONARY-ARTERY VASODILATION WITH ADENOSINE
    VERANI, MS
    MAHMARIAN, JJ
    AMERICAN JOURNAL OF CARDIOLOGY, 1991, 67 (14): : D12 - D17
  • [45] Myocardial blood flow analysis of stress dynamic myocardial CT perfusion for hemodynamically significant coronary artery disease diagnosis: The clinical value of relative parameter optimization
    Yi, Yan
    Xu, Cheng
    Wu, Wei
    Wang, Yun
    Li, Yu-Mei
    Shen, Zhu-Jun
    Jin, Zheng-Yu
    Wang, Yi-Ning
    JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2020, 14 (04) : 314 - 321
  • [46] NORMAL-APPEARING CAPTOPRIL MAG-3 RENAL SCINTIGRAPHY IN HEMODYNAMICALLY SIGNIFICANT RENAL-ARTERY STENOSIS
    MANSOOR, GA
    WHITE, WB
    FRIEDMAN, NC
    ANGIOLOGY, 1995, 46 (10) : 929 - 935
  • [47] Fully automated pixel-wise quantitative CMR-myocardial perfusion with CMR-coronary angiography to detect hemodynamically significant coronary artery disease
    Shi-hai Zhao
    Wei-feng Guo
    Zhi-feng Yao
    Shan Yang
    Hong Yun
    Yin-yin Chen
    Tong-tong Han
    Xiao-yue Zhou
    Cai-xia Fu
    Meng-su Zeng
    Chen-guang Li
    Cui-zhen Pan
    Hang Jin
    European Radiology, 2023, 33 : 7238 - 7249
  • [48] Fully automated pixel-wise quantitative CMR-myocardial perfusion with CMR-coronary angiography to detect hemodynamically significant coronary artery disease
    Zhao, Shi-hai
    Guo, Wei-feng
    Yao, Zhi-feng
    Yang, Shan
    Yun, Hong
    Chen, Yin-yin
    Han, Tong-tong
    Zhou, Xiao-yue
    Fu, Cai-xia
    Zeng, Meng-su
    Li, Chen-guang
    Pan, Cui-zhen
    Jin, Hang
    EUROPEAN RADIOLOGY, 2023, 33 (10) : 7238 - 7249
  • [49] Combined CT Coronary Angiography and Stress Myocardial Perfusion Imaging for Hemodynamically Significant Stenoses in Patients With Suspected Coronary Artery Disease A Comparison With Fractional Flow Reserve
    Ko, Brian S.
    Cameron, James D.
    Leung, Michael
    Meredith, Ian T.
    Leong, Darryl P.
    Antonis, Paul R.
    Crossett, Marcus
    Troupis, John
    Harper, Richard
    Malaiapan, Yuvaraj
    Seneviratne, Sujith K.
    JACC-CARDIOVASCULAR IMAGING, 2012, 5 (11) : 1097 - 1111
  • [50] Reply to Letter to the Editor: “Fully automated pixel‑wise quantitative CMR‑myocardial perfusion with CMR‑coronary angiography to detect hemodynamically significant coronary artery disease”