Experimental investigations on prefabricated interlocking prestressed tendon composite joint and its application to beam-column connection

被引:1
|
作者
Ding, Yingnan [1 ,2 ]
Xu, Weibing [1 ]
Wang, Jin [3 ]
Chen, Yanjiang [1 ]
Du, Xiuli [1 ]
Shen, Botan [1 ]
Zhao, Zhuo [1 ]
机构
[1] Beijing Univ Technol, Natl Key Lab Bridge Safety & Resilience, Beijing 100124, Peoples R China
[2] Tongji Univ, Coll Civil Engn, Shanghai 200092, Peoples R China
[3] North China Elect Power Univ, Sch Water Resources & Hydropower Engn, Beijing 102206, Peoples R China
来源
基金
北京市自然科学基金; 中国国家自然科学基金;
关键词
Prefabricated; Interlocking prestressed tendon composite joint; (I-PTCJ); Multi -story structure; Seismic performance; PRECAST SEGMENTAL COLUMN; SEISMIC BEHAVIOR; SHAKE TABLE; CONCRETE; PERFORMANCE; TESTS;
D O I
10.1016/j.jobe.2024.110140
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This study proposes an interlocking prestressed tendon composite joint (I-PTCJ) that can be applied to a beam-column connection of the multi-story structure. First, the main structure and prefabrication process of the I-PTCJ were introduced. Next, three beam-column specimens using local and integral I-PTCJs (named specimens PT1 and PT2) and a traditional interlocking joint (IJ, specimen named TG1) were designed and manufactured. Furthermore, quasi-static experiments were performed on these three specimens to evaluate their seismic performance. In addition, the influence of the prestressed tendons (PTs) and the arrangement mode (local or integral) of the IPTCJs were investigated in detail. Finally, a preliminary comparative analysis between the experimental and simulated results was carried out. The results showed that the introduction of the PTs reduced the degree of damage within the PT installation area, delayed the cracking of the interlocking interface, and improved the bond performance of the longitudinal rebar. However, it also aggravated the degree of damage outside the PT installation area and reduced the displacement ductility and energy dissipation capacity of the specimen. Compared with TG1 (using the traditional I-J), PT1 (using the local I-PTCJ) had a higher peak load, lower displacement ductility, higher shear deformation, gentler rigidity deterioration, and lower cumulative energy dissipation. Compared with PT1, PT2 (using the integral I-PTCJ) had a higher peak load, lower displacement ductility, lower shear deformation, lower cumulative energy dissipation, and better bond performance of the longitudinal rebar. Both the yield displacement angle and ultimate displacement angle met the deformability requirement of the existing building design codes. Thus, the proposed I-PTCJ can be applied to the beam-column connection of multi-story structures.
引用
收藏
页数:22
相关论文
共 50 条
  • [21] Experimental and numerical investigation of prefabricated prestressed vertical steel strand core tube flange column connection joint
    Zhang Yan-xia
    Huang Zhe-wen
    Li Yang-long
    Jin Bo-wen
    Cheng Xiao-tian
    Cheng Meng-yao
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2022, 190
  • [22] Experimental and numerical study on the prefabricated double L-shaped beam-column joint with triangular stiffener
    Yang, Zhaoyuan
    Cao, Wanlin
    Qiao, Qiyun
    Zhang, Jianwei
    JOURNAL OF BUILDING ENGINEERING, 2023, 69
  • [23] Experimental study on seismic performance of prefabricated column-column connection with prestressed steel strands
    Zhang, Ailin
    Li, Xinxia
    Yang, Zheng
    Zhang, Yanxia
    Cheng, Mengyao
    JOURNAL OF BUILDING ENGINEERING, 2022, 47
  • [24] Experimental and numerical investigations of seismic performance of stepped beam-column joints with different connection forms
    Cheng, Xin
    Li, Yun
    An, Yi
    Liu, Jianfei
    Zhang, Ruibin
    Liao, Fangfang
    JOURNAL OF BUILDING ENGINEERING, 2024, 91
  • [25] Design of partially prestressed concrete beam-column connection with singly prestressed sections under cyclic loadings
    Budiono, IB
    COMPUTATIONAL METHODS AND TESTING FOR ENGINEERING INTEGRITY, 1996, : 207 - 216
  • [26] Seismic behaviour of an earthquake-resilient prefabricated beam-column cross joint
    Zhang, Ai-lin
    Wu, Ying-xia
    Jiang, Zi-qin
    Zhang, Xu-qiao
    Dou, Chao
    JOURNAL OF ZHEJIANG UNIVERSITY-SCIENCE A, 2017, 18 (12): : 927 - 941
  • [27] Experimental Research on Seismic Behavior of Haunched Concrete Beam-Column Joint Based on the Bolt Connection
    Zhang, Yang
    Ma, Wei
    Li, Xin
    Li, Kai
    SUSTAINABILITY, 2022, 14 (23)
  • [28] Experimental and numerical investigation on seismic performance of a composite wide beam-column interior joint
    Bohara, Rajendra Prasad
    Tanapornraweekit, Ganchai
    Tangtermsirikul, Somnuk
    STRUCTURES, 2021, 30 : 560 - 573
  • [29] Seismic behaviour of a precast prestressed beam-column joint with energy dissipation bars
    Fan, Jiajun
    Wu, Gang
    Cao, Yu
    MAGAZINE OF CONCRETE RESEARCH, 2020, 72 (07) : 365 - 378
  • [30] Experimental Studies on Mechanical Properties of Fabricated Beam-Column Connection with Inner Sleeve Composite Bolts
    Ma Q.
    Wang Y.
    Yang S.
    Tianjin Daxue Xuebao (Ziran Kexue yu Gongcheng Jishu Ban)/Journal of Tianjin University Science and Technology, 2017, 50 : 131 - 139