Performance evaluation of deep learning image reconstruction algorithm for dual-energy spectral CT imaging: A phantom study

被引:1
|
作者
Li, Haoyan [1 ]
Li, Zhentao [2 ]
Gao, Shuaiyi [1 ]
Hu, Jiaqi [1 ]
Yang, Zhihao [1 ]
Peng, Yun [1 ]
Sun, Jihang [1 ]
机构
[1] Capital Med Univ, Beijing Childrens Hosp, Natl Ctr Childrens Hlth, Dept Radiol, 56 Nanlishi Rd, Beijing 100045, Peoples R China
[2] Peking Univ, Dept Radiol, Peoples Hosp, Beijing, Peoples R China
关键词
Multidetector computed tomography; image enhancement; image reconstruction; deep learning; TOMOGRAPHY PHYSICAL PRINCIPLES; FILTERED BACK-PROJECTION; NOISE POWER SPECTRUM; ITERATIVE RECONSTRUCTION; CHEST CT; DOSE REDUCTION; LIVER-LESIONS; CONTRAST; QUALITY; DETECTABILITY;
D O I
10.3233/XST-230333
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
OBJECTIVES: To evaluate the performance of deep learning image reconstruction (DLIR) algorithm in dual-energy spectral CT (DEsCT) as a function of radiation dose and image energy level, in comparison with filtered-back-projection (FBP) and adaptive statistical iterative reconstruction-V (ASIR-V) algorithms. METHODS: An ACR464 phantom was scanned with DEsCT at four dose levels (3.5 mGy, 5 mGy, 7.5 mGy, and 10 mGy). Virtual monochromatic images were reconstructed at five energy levels (40 keV, 50 keV, 68 keV, 74 keV, and 140 keV) using FBP, 50% and 100% ASIR-V, DLIR at low (DLIR-L), medium (DLIR-M), and high (DLIR-H) settings. The noise power spectrum (NPS), task-based transfer function (TTF) and detectability index (d') were computed and compared among reconstructions. RESULTS: NPS area and noise increased as keV decreased, with DLIR having slower increase than FBP and ASIR-V, and DLIR-H having the lowest values. DLIR had the best 40 keV/140 keV noise ratio at various energy levels, DLIR showed higher TTF (50%) than ASIR-V for all materials, especially for the soft tissue-like polystyrene insert, and DLIR-M and DLIR-H provided higher d' than DLIR-L, ASIR-V and FBP in all dose and energy levels. As keV increases, d' increased for acrylic insert, and d' of the 50 keV DLIR-M and DLIR-H images at 3.5 mGy (7.39 and 8.79, respectively) were higher than that (7.20) of the 50 keV ASIR-V50% images at 10 mGy. CONCLUSIONS: DLIR provides better noise containment for low keV images in DEsCT and higher TTF(50%) for the polystyrene insert over ASIR-V. DLIR-H has the lowest image noise and highest detectability in all dose and energy levels. DEsCT 50 keV images with DLIR-M and DLIR-H show potential for 65% dose reduction over ASIR-V50% with higher d'.
引用
收藏
页码:513 / 528
页数:16
相关论文
共 50 条
  • [31] Comparison of two versions of a deep learning image reconstruction algorithm on CT image quality and dose reduction: A phantom study
    Greffier, Joel
    Dabli, Djamel
    Frandon, Julien
    Hamard, Aymeric
    Belaouni, Asmaa
    Akessoul, Philippe
    Fuamba, Yannick
    Le Roy, Julien
    Guiu, Boris
    Beregi, Jean-Paul
    MEDICAL PHYSICS, 2021, 48 (10) : 5743 - 5755
  • [32] A deep learning approach for dual-energy CT imaging using a single-energy CT data
    Zhao, Wei
    Lv, Tianling
    Gao, Peng
    Shen, Liyue
    Dai, Xianjin
    Cheng, Kai
    Jia, Mengyu
    Chen, Yang
    Xing, Lei
    15TH INTERNATIONAL MEETING ON FULLY THREE-DIMENSIONAL IMAGE RECONSTRUCTION IN RADIOLOGY AND NUCLEAR MEDICINE, 2019, 11072
  • [33] Evaluation of a commercial deformable image registration algorithm for dual-energy CT processing
    Huang, Jessie Y.
    Lawless, Michael J.
    Matrosic, Charles K.
    Di Maso, Lianna D.
    Miller, Jessica R.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2020, 21 (09): : 227 - 234
  • [34] Deep learning image reconstruction algorithm for pancreatic protocol dual-energy computed tomography: image quality and quantification of iodine concentration
    Noda, Yoshifumi
    Kawai, Nobuyuki
    Nagata, Shoma
    Nakamura, Fumihiko
    Mori, Takayuki
    Miyoshi, Toshiharu
    Suzuki, Ryosuke
    Kitahara, Fumiya
    Kato, Hiroki
    Hyodo, Fuminori
    Matsuo, Masayuki
    EUROPEAN RADIOLOGY, 2022, 32 (01) : 384 - 394
  • [35] Dual-energy CT: a phantom comparison of different platforms for abdominal imaging
    Thorsten Sellerer
    Peter B. Noël
    Manuel Patino
    Anushri Parakh
    Sebastian Ehn
    Sascha Zeiter
    Jasmin A. Holz
    Johannes Hammel
    Alexander A. Fingerle
    Franz Pfeiffer
    David Maintz
    Ernst J. Rummeny
    Daniela Muenzel
    Dushyant V. Sahani
    European Radiology, 2018, 28 : 2745 - 2755
  • [36] Comparing two deep learning spectral reconstruction levels for abdominal evaluation using a rapid-kVp-switching dual-energy CT scanner
    Sagdic, Hakki Serdar
    Hosseini-Siyanaki, Mohammadreza
    Raviprasad, Abheek
    Munjerin, Sefat
    Fabri, Daniella
    Grajo, Joseph
    Tonso, Victor Martins
    Magnelli, Laura
    Hochhegger, Daniela
    Anthony, Evelyn
    Hochhegger, Bruno
    Forghani, Reza
    ABDOMINAL RADIOLOGY, 2025,
  • [37] Deep learning image reconstruction algorithm for pancreatic protocol dual-energy computed tomography: image quality and quantification of iodine concentration
    Yoshifumi Noda
    Nobuyuki Kawai
    Shoma Nagata
    Fumihiko Nakamura
    Takayuki Mori
    Toshiharu Miyoshi
    Ryosuke Suzuki
    Fumiya Kitahara
    Hiroki Kato
    Fuminori Hyodo
    Masayuki Matsuo
    European Radiology, 2022, 32 : 384 - 394
  • [38] Dual-energy CT: a phantom comparison of different platforms for abdominal imaging
    Sellerer, Thorsten
    Noel, Peter B.
    Patino, Manuel
    Parakh, Anushri
    Ehn, Sebastian
    Zeiter, Sascha
    Holz, Jasmin A.
    Hammel, Johannes
    Fingerle, Alexander A.
    Pfeiffer, Franz
    Maintz, David
    Rummeny, Ernst J.
    Muenzel, Daniela
    Sahani, Dushyant V.
    EUROPEAN RADIOLOGY, 2018, 28 (07) : 2745 - 2755
  • [39] Deep Learning Imaging Reconstruction Algorithm for Carotid Dual Energy CT Angiography: Opportunistic Evaluation of Cervical Intervertebral Discs-A Preliminary Study
    Jiang, Chenyu
    Zhang, Jingxin
    Li, Wenhuan
    Li, Yali
    Ni, Ming
    Jin, Dan
    Zhang, Yan
    Jiang, Liang
    Yuan, Huishu
    JOURNAL OF IMAGING INFORMATICS IN MEDICINE, 2024, 37 (04): : 1960 - 1968
  • [40] Technical performance of a dual-energy CT system with a novel deep-learning based reconstruction process: Evaluation using an abdomen protocol
    Oostveen, Luuk J.
    Boedeker, Kirsten L.
    Balta, Christiana
    Shin, Daniel
    de Lange, Frank
    Prokop, Mathias
    Sechopoulos, Ioannis
    MEDICAL PHYSICS, 2023, 50 (03) : 1378 - 1389