Cancer treatment is a continuous process, that the current therapy cannot meet the requirement well, including radiotherapy and chemotherapy. Wearable ultrasound device has the potential for continuous sonodynamic therapy due to its portability. However, the miniaturization of ultrasonic probe, system integration of device, and the strategy of continuous treatment are still urgent issues to be addressed. Herein, a portable wearable antitumor system is introduced, which utilizes a custom-developed multiplexed ultrasonic patch array (CWUS Patch) to accurately focus ultrasound on the lesion site and controllably stimulate sonosensitizer to produce a large amount of toxic reactive oxygen species (ROS). The system enables dynamic control of the ultrasound patches and allows real-time adjustments to optimize their performance in various applications, providing greater flexibility and precision in healthcare technology. Furthermore, the excellent penetration property of ultrasound into tumor tissues that induce synchronous apoptosis of tumor cells from the inside out is verified through a mouse model of breast cancer. This fully integrated conformal wearable ultrasound system provides a promising approach to noninvasively, continuously, and efficiently treat deep tumors. This work proposes a portable, wearable ultrasound system for continuous sonodynamic therapy. The integration of a multiplexed ultrasonic patch array possesses ability to accurately focus on lesion sites and produce reactive oxygen species (ROS), ultimately driving the extinction of tumor tissue from the inside out. This study provides a promising approach to noninvasively, continuously, and efficiently treat deep tumors. image
引用
收藏
页数:10
相关论文
共 50 条
  • [21] A wearable patch for continuous analysis of thermoregulatory sweat at rest
    Nyein, Hnin Yin Yin
    Bariya, Mallika
    Tran, Brandon
    Ahn, Christine Heera
    Brown, Brenden Janatpour
    Ji, Wenbo
    Davis, Noelle
    Javey, Ali
    NATURE COMMUNICATIONS, 2021, 12 (01)
  • [22] A wearable patch for continuous analysis of thermoregulatory sweat at rest
    Hnin Yin Yin Nyein
    Mallika Bariya
    Brandon Tran
    Christine Heera Ahn
    Brenden Janatpour Brown
    Wenbo Ji
    Noelle Davis
    Ali Javey
    Nature Communications, 12
  • [23] Fully Integrated, Stretchable, Wireless Skin-Conformal Bioelectronics for Continuous Stress Monitoring in Daily Life
    Kim, Hojoong
    Kim, Yun-Soung
    Mahmood, Musa
    Kwon, Shinjae
    Zavanelli, Nathan
    Kim, Hee Seok
    Rim, You Seung
    Epps, Fayron
    Yeo, Woon-Hong
    ADVANCED SCIENCE, 2020, 7 (15)
  • [24] Fully integrated wearable humidity sensor for respiration monitoring
    Jin, Xiaofeng
    Zha, Lin
    Wang, Fan
    Wang, Yongzhong
    Zhang, Xueji
    FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2022, 10
  • [25] Fully integrated wearable humidity sensor for respiration monitoring
    Jin, Xiaofeng
    Zha, Lin
    Wang, Fan
    Wang, Yongzhong
    Zhang, Xueji
    Frontiers in Bioengineering and Biotechnology, 2022, 10
  • [26] Design and analysis of a conformal patch antenna for a wearable breast hyperthermia treatment system
    Curto, Sergio
    Ramasamy, Manoshika
    Suh, Minyoung
    Prakash, Punit
    ENERGY-BASED TREATMENT OF TISSUE AND ASSESSMENT VIII, 2015, 9326
  • [27] Ultrasound triggered drug delivery for mitochondria targeted sonodynamic therapy
    Chen, MengJia
    Xu, Airen
    He, Wenyue
    Ma, Weicheng
    Shen, Song
    JOURNAL OF DRUG DELIVERY SCIENCE AND TECHNOLOGY, 2017, 39 : 501 - 507
  • [28] Continuous Ketone Monitoring via Wearable Microneedle Patch Platform
    Moonla, Chochanon
    Reynoso, Maria
    Casanova, Ana
    Chang, An-Yi
    Djassemi, Omeed
    Balaje, Aishwarya
    Abbas, Amal
    Li, Zhengxing
    Mahato, Kuldeep
    Wang, Joseph
    ACS SENSORS, 2024, 9 (02) : 1004 - 1013
  • [29] A wearable patch for continuous monitoring of sweat electrolytes during exertion
    Alizadeh, Azar
    Burns, Andrew
    Lenigk, Ralf
    Gettings, Rachel
    Ashe, Jeffrey
    Porter, Adam
    McCaul, Margaret
    Barrett, Ruairi
    Diamond, Dermot
    White, Paddy
    Skeath, Perry
    Tomczak, Melanie
    LAB ON A CHIP, 2018, 18 (17) : 2632 - 2641
  • [30] Fully Stretchable Capillary Microfluidics-Integrated Nanoporous Gold Electrochemical Sensor for Wearable Continuous Glucose Monitoring
    Bae, Chan Wool
    Phan Tan Toi
    Kim, Bo Yeong
    Lee, Won Il
    Lee, Han Byeol
    Hanif, Adeela
    Lee, Eung Hyuk
    Lee, Nae-Eung
    ACS APPLIED MATERIALS & INTERFACES, 2019, 11 (16) : 14567 - 14575