A Fully Integrated Conformal Wearable Ultrasound Patch for Continuous Sonodynamic Therapy

被引:6
|
作者
Zou, Faxing [1 ]
Luo, Yong [1 ]
Zhuang, Wenxuan [1 ]
Xu, Tailin [1 ]
机构
[1] Shenzhen Univ, Inst Adv Study IAS, Shenzhen 518060, Guangdong, Peoples R China
关键词
antitumor; sonodynamic therapy; ultrasound patch; wearable; DRUG-DELIVERY; CANCER;
D O I
10.1002/adma.202409528
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Cancer treatment is a continuous process, that the current therapy cannot meet the requirement well, including radiotherapy and chemotherapy. Wearable ultrasound device has the potential for continuous sonodynamic therapy due to its portability. However, the miniaturization of ultrasonic probe, system integration of device, and the strategy of continuous treatment are still urgent issues to be addressed. Herein, a portable wearable antitumor system is introduced, which utilizes a custom-developed multiplexed ultrasonic patch array (CWUS Patch) to accurately focus ultrasound on the lesion site and controllably stimulate sonosensitizer to produce a large amount of toxic reactive oxygen species (ROS). The system enables dynamic control of the ultrasound patches and allows real-time adjustments to optimize their performance in various applications, providing greater flexibility and precision in healthcare technology. Furthermore, the excellent penetration property of ultrasound into tumor tissues that induce synchronous apoptosis of tumor cells from the inside out is verified through a mouse model of breast cancer. This fully integrated conformal wearable ultrasound system provides a promising approach to noninvasively, continuously, and efficiently treat deep tumors. This work proposes a portable, wearable ultrasound system for continuous sonodynamic therapy. The integration of a multiplexed ultrasonic patch array possesses ability to accurately focus on lesion sites and produce reactive oxygen species (ROS), ultimately driving the extinction of tumor tissue from the inside out. This study provides a promising approach to noninvasively, continuously, and efficiently treat deep tumors. image
引用
收藏
页数:10
相关论文
共 50 条
  • [1] A wearable ultrasound patch for continuous heart imaging
    Hu, Hongjie
    Huang, Hao
    NATURE, 2023,
  • [2] Fully integrated flexible biosensor for wearable continuous glucose monitoring
    Jin, Xiaofeng
    Li, Guanhua
    Xu, Tailin
    Su, Lei
    Yan, Dan
    Zhang, Xueji
    BIOSENSORS & BIOELECTRONICS, 2022, 196
  • [3] Fully Integrated Wearable Device for Continuous Sweat Lactate Monitoring in Sports
    Xuan, Xing
    Chen, Chen
    Molinero-Fernandez, Agueda
    Ekelund, Emil
    Cardinale, Daniele
    Swaren, Mikael
    Wedholm, Lars
    Cuartero, Maria
    Crespo, Gaston A.
    ACS SENSORS, 2023, 8 (06) : 2401 - 2409
  • [4] A fully integrated wearable ultrasound system to monitor deep tissues in moving subjects
    Lin, Muyang
    Zhang, Ziyang
    Gao, Xiaoxiang
    Bian, Yizhou
    Wu, Ray S. S.
    Park, Geonho
    Lou, Zhiyuan
    Zhang, Zhuorui
    Xu, Xiangchen
    Chen, Xiangjun
    Kang, Andrea
    Yang, Xinyi
    Yue, Wentong
    Yin, Lu
    Wang, Chonghe
    Qi, Baiyan
    Zhou, Sai
    Hu, Hongjie
    Huang, Hao
    Li, Mohan
    Gu, Yue
    Mu, Jing
    Yang, Albert
    Yaghi, Amer
    Chen, Yimu
    Lei, Yusheng
    Lu, Chengchangfeng
    Wang, Ruotao
    Wang, Joseph
    Xiang, Shu
    Kistler, Erik B.
    Vasconcelos, Nuno
    Xu, Sheng
    NATURE BIOTECHNOLOGY, 2024, 42 (03) : 448 - 457
  • [5] A fully integrated wearable ultrasound system to monitor deep tissues in moving subjects
    Muyang Lin
    Ziyang Zhang
    Xiaoxiang Gao
    Yizhou Bian
    Ray S. Wu
    Geonho Park
    Zhiyuan Lou
    Zhuorui Zhang
    Xiangchen Xu
    Xiangjun Chen
    Andrea Kang
    Xinyi Yang
    Wentong Yue
    Lu Yin
    Chonghe Wang
    Baiyan Qi
    Sai Zhou
    Hongjie Hu
    Hao Huang
    Mohan Li
    Yue Gu
    Jing Mu
    Albert Yang
    Amer Yaghi
    Yimu Chen
    Yusheng Lei
    Chengchangfeng Lu
    Ruotao Wang
    Joseph Wang
    Shu Xiang
    Erik B. Kistler
    Nuno Vasconcelos
    Sheng Xu
    Nature Biotechnology, 2024, 42 : 448 - 457
  • [6] ULTRASOUND DOSE FRACTIONATION IN SONODYNAMIC THERAPY
    Barati, Amir H.
    Mokhtari-Dizaji, Manijeh
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2010, 36 (06): : 880 - 887
  • [7] A Triband Slot Patch Antenna for Conformal and Wearable Applications
    Li, Erfeng
    Li, Xue Jun
    Seet, Boon-Chong
    ELECTRONICS, 2021, 10 (24)
  • [8] Microfluidic-Integrated Multimodal Wearable Hybrid Patch for Wireless and Continuous Physiological Monitoring
    Zahed, Md Abu
    Kim, Dong Kyun
    Jeong, Seong Hoon
    Reza, Md Selim
    Sharifuzzaman, Md
    Pradhan, Gagan Bahadur
    Song, Hyesu
    Asaduzzaman, Md
    Park, Jae Yeong
    ACS SENSORS, 2023, 8 (08) : 2960 - 2974
  • [9] An Integrated Wearable Sweat Sensing Patch for Passive Continuous Analysis of Stress Biomarkers at Rest
    Zhao, Hao
    Zhang, Xieli
    Qin, Yanxia
    Xia, Yong
    Xu, Xin
    Sun, Xiguang
    Yu, Dehai
    Mugo, Samuel M.
    Wang, Dong
    Zhang, Qiang
    ADVANCED FUNCTIONAL MATERIALS, 2023, 33 (09)
  • [10] Ultrasound activated nanosensitizers for sonodynamic therapy and theranostics
    Li, Lei
    Lin, Huirong
    Li, Dengfeng
    Zeng, Yun
    Liu, Gang
    BIOMEDICAL MATERIALS, 2021, 16 (02)