The relative merits of using a high-sensitivity cardiac Troponin T assay compared to a nonhigh-sensitivity troponin T assay after noncardiac surgery

被引:0
|
作者
Borges, Flavia K. [1 ,2 ,3 ]
Sessler, Daniel I. [4 ]
Tiboni, Maria [2 ]
Patel, Ameen [2 ]
Lemanach, Yannick [1 ,2 ,3 ]
Heels-Ansdell, Diane [3 ]
Srinathan, Sadeesh [5 ]
Wang, Chew Yin [6 ]
Chow, Clara [7 ,8 ]
Duceppe, Emmanuelle [1 ,9 ]
Kavsak, Peter [10 ]
Ofori, Sandra N. [1 ,2 ]
Pettit, Shirley [1 ]
Berwanger, Otavio [11 ,12 ]
Kurz, Andrea [13 ,14 ]
Turan, Alparslan [13 ]
Tonelli, Ana Claudia [15 ,16 ]
Devereaux, P. J. [1 ,2 ,3 ]
机构
[1] Populat Hlth Res Inst, Perioperat Med & Surg Res Unit, Hamilton, ON, Canada
[2] McMaster Univ, Dept Med, Hamilton, ON, Canada
[3] McMaster Univ, Dept Hlth Res Methods Evidence & Impact, Hamilton, ON, Canada
[4] Cleveland Clin, Dept Outcomes Res, Cleveland, OH USA
[5] Univ Manitoba, Dept Surg, Winnipeg, MB, Canada
[6] Univ Malaya, Dept Anaesthesiol, Kuala Lumpur, Wilayah Perseku, Malaysia
[7] Univ Sydney, Westmead Appl Res Ctr WARC, Dept Cardiol, Westmead, NSW, Australia
[8] Westmead Hosp, Westmead, NSW, Australia
[9] Univ Montreal, Dept Med, Montreal, PQ, Canada
[10] McMaster Univ, Dept Pathol & Mol Med, Hamilton, ON, Canada
[11] George Inst Global Hlth UK, London, England
[12] Imperial Coll London, London, England
[13] Cleveland Clin, Anesthesiol Inst, Dept Gen Anesthesiol & Outcomes Res, Cleveland, OH USA
[14] Med Univ Graz, Dept Gen Anesthesiol Emergency & Intens Care Med, Graz, Austria
[15] Unisinos Univ, Dept Med, Sao Leopoldo, Brazil
[16] Hosp Clin Porto Alegre, Dept Internal Med, Internal Med Serv, Porto Alegre, Brazil
基金
加拿大健康研究院;
关键词
MYOCARDIAL-INFARCTION; 30-DAY MORTALITY; INJURY; ASSOCIATION; GUIDELINES; MANAGEMENT; DIAGNOSIS;
D O I
10.1016/j.ahj.2024.05.020
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction Troponin elevation after noncardiac surgery is associated with an elevated risk of 30-day mortality. Little is known about relative merit of using a high-sensitivity Troponin T (hsTnT), the fifth-generation assay, vs the nonhigh sensitivity Troponin T (non-hsTnT), the fourth-generation assay, in the noncardiac surgery setting. We aimed to identify whether hsTnT can identify additional patients at risk that would have gone undetected with non-hsTnT measurement. Methods The VISION Study included 40,004 noncardiac surgery patients with postoperative troponin measurements. Among them, 1,806 patients had both fourth-generation non-hsTnT and fifth-generation hsTnT concomitant measurements (4,451 paired results). We compared the absolute concentrations, the timing, and the impact of different thresholds on predicting 30-day major cardiovascular complications (composite of death, nonfatal cardiac arrest, coronary revascularization, and congestive heart failure). Results Based on the manufacturers' threshold of 14 ng/L, 580 (32.1%) patients had postoperative hsTnT concentrations greater than the threshold, while their non-hsTnT concentrations were below the manufacturer's threshold. These 580 patients had higher risk of major cardiovascular events (OR 2.33; CI 95% 1.04-5.23; P = .049) than patients with hsTnT concentrations below the manufacturer threshold. Among patients with myocardial injury after noncardiac surgery, only 50% would be detected by the fourth-generation non-hsTnT assay at 6 to 12 hours postoperative as compared to 85% with the fifth-generation hsTnT assay ( P -value < .001). Conclusions Within the first 3 postoperative days, fifth-generation hsTnT identified at least 1 in 3 patients with troponin elevation that would have gone undetected by fourth-generation non-hsTnT using published thresholds in this setting. Furthermore, fifth-generation hsTnT identified patients with an elevation earlier than fourth-generation non-hsTnT, indicating potential to improve postoperative risk stratification. (Am Heart J 2024;275:45-52.)
引用
收藏
页码:45 / 52
页数:8
相关论文
共 50 条
  • [21] Diagnostic Validation of a High-Sensitivity Cardiac Troponin I Assay
    Soerensen, Nils A.
    Gossling, Alina
    Neumann, Johannes T.
    Hartikainen, Tau S.
    Haller, Paul M.
    Scharlemann, Lea
    Lehmacher, Jonas
    Ziegler, Andreas
    Blankenberg, Stefan
    Zeller, Tanja
    Nordholt, Gerhard
    Renne, Thomas
    Westermann, Dirk
    CLINICAL CHEMISTRY, 2021, 67 (09) : 1230 - 1239
  • [22] Cardiac troponin measured by a high-sensitivity assay in hypertensive patients
    Gluszek, Jerzy
    Kosicka, Teresa
    ARTERIAL HYPERTENSION, 2018, 22 (03): : 107 - 112
  • [23] Prediction of Death After Noncardiac Surgery: Potential Advantage of Using High-Sensitivity Troponin T as a Continuous Variable
    Machado, Mauricio N.
    Rodrigues, Fernando B.
    Nakazone, Marcelo A.
    Martin, Danilo F.
    Sabbag, Amalia T. R.
    Grigolo, Ingrid H.
    Silva-Junior, Osvaldo L.
    Maia, Lilia N.
    Jaffe, Allan S.
    JOURNAL OF THE AMERICAN HEART ASSOCIATION, 2021, 10 (06):
  • [24] Diagnosis of Acute Myocardial Infarction in Hemodialysis Patients With High-Sensitivity Cardiac Troponin T Assay
    Huang, Hua-Lan
    Zhu, Shuai
    Wang, Wei-Qing
    Nie, Xin
    Shi, Ying-Ying
    He, Yong
    Song, Hao-Lan
    Miao, Qiang
    Fu, Ping
    Wang, Lan-Lan
    Li, Gui-Xing
    ARCHIVES OF PATHOLOGY & LABORATORY MEDICINE, 2016, 140 (01) : 75 - 80
  • [25] Performance evaluation of a novel high-sensitivity cardiac troponin T assay: analytical and clinical perspectives
    Li, Zhongxin
    Yang, Shuo
    Qiao, Jiao
    Tan, Yuan
    Liu, Qi
    Yang, Boxin
    Feng, Weimin
    Cui, Liyan
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2024, 62 (05) : 979 - 987
  • [26] Outcomes in Patients With Chest Pain Discharged After Evaluation Using a High-Sensitivity Troponin T Assay
    Nejatian, Atosa
    Omstedt, Asa
    Hoijer, Jonas
    Hansson, L. O.
    Djarv, Therese
    Eggers, Kai M.
    Svensson, Per
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2017, 69 (21) : 2622 - 2630
  • [27] Using High-Sensitivity Cardiac Troponin T for Acute Cardiac Care
    Sandoval, Yader
    Jaffe, Allan S.
    AMERICAN JOURNAL OF MEDICINE, 2017, 130 (12): : 1358 - +
  • [28] Clinical Implications of a Recent Adjustment to the High-Sensitivity Cardiac Troponin T Assay: User Beware
    Apple, Fred S.
    Jaffe, Allan S.
    CLINICAL CHEMISTRY, 2012, 58 (11) : 1599 - 1600
  • [29] Clinical implications of a recent adjustment to the high-sensitivity cardiac troponin T assay: some results
    Franzini, Maria
    Masotti, Silvia
    Prontera, Concetta
    Passino, Claudio
    Clerico, Aldo
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2014, 52 (02) : E21 - E23
  • [30] False decrease of high-sensitivity cardiac troponin T assay in pneumatic tube system samples
    Wei, Jia
    Wu, Yi-ning
    Ling, Yun
    Chen, Xiao-ting
    Zhu, Qiong
    Xu, Jian
    CLINICA CHIMICA ACTA, 2019, 495 : 507 - 511