Infrared Non-Invasive Exhaled Biomarker Sensing: A Review

被引:2
|
作者
Uthra, B. [1 ,2 ,3 ,4 ]
Rahman, Md. Ataur [3 ,4 ]
Sriram, Sharath [3 ,4 ]
Agarwal, Pankaj B. [1 ,2 ]
机构
[1] Cent Elect Engn Res Inst, Semicond Proc Technol Grp, CSIR, Pilani 333031, Rajasthan, India
[2] Acad Sci & Innovat Res AcSIR, Ghaziabad 201002, India
[3] RMIT Univ, Funct Mat & Microsyst Res Grp, Melbourne, Vic 3001, Australia
[4] RMIT Univ, ARC Ctr Excellence Transformat Meta Opt Syst, Melbourne, Vic 3001, Australia
来源
ADVANCED SENSOR RESEARCH | 2024年 / 3卷 / 01期
关键词
exhaled breath diagnosis; IR detectors; MIR gas sensors; NDIR gas sensor; PAS gas sensor; VOCs detection; VOLATILE ORGANIC-COMPOUNDS; BREATH AMMONIA ANALYSIS; CHRONIC KIDNEY-DISEASE; PHOTOACOUSTIC-SPECTROSCOPY; CARBON-DIOXIDE; LUNG-CANCER; MU-M; LASER SPECTROSCOPY; LIPID-PEROXIDATION; MASS-SPECTROMETRY;
D O I
10.1002/adsr.202300085
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Exhaled breath analysis is considered an effective tool for diagnosing the patient's metabolic status because of its non-invasive nature. Gas chromatography-mass spectrometry (GC-MS) and other mass spectrometry techniques are widely used for exhaled breath analysis. Nevertheless, the requirement of a handheld device for real-time analysis and rapid processing time of multiple samples leads to advancing infrared (IR) based breath gas sensing techniques. Herein, the IR gas sensing technologies are discussed with a focus on non-dispersive infrared (NDIR), photoacoustic (PAS), and tunable diode laser absorption spectroscopy (TDLAS) gas sensing technologies because of their highly selective gas detection among compound gases (mixture of VOCs), as well as their corresponding sensing mechanisms and characteristics, for real-time monitoring of exhaled biomarkers. Carbon dioxide, acetone, ammonia, nitric oxide, methane, and ethylene are the significant biomarkers elaborated in this work with their respective clinical applications and the significance of non-invasive real-time monitoring using IR detectors. Challenges in selectivity and clinical trials leads to focus on this review. Current market analysis, present status of different techniques to detect specific biomarkers and other challenges with their possible solutions discussed in this review aid in developing highly selective IR-based handheld breath VOC analyzers for early diagnosis and screening. Clinical adaptation of the fast-growing breath VOC sensors confronts the challenges as non-invasive techniques with rapid response time, clinical trial limitations, and development of a miniaturized, handheld device for real-time monitoring. This review focuses on important aspects of IR-techniques for developing such devices, current market analysis, analyzing critical biomarkers for early screening of diseases, and future trends for personalized tele medicine systems. image
引用
收藏
页数:20
相关论文
共 50 条
  • [31] Non-Invasive Measurement of Plasma Triglycerides from Exhaled Breath
    Minh, Timothy D. C.
    Oliver, Stacy R.
    Blake, Donald R.
    Carson, Matthew K.
    Meinardi, Simone
    Galassetti, Pietro R.
    DIABETES, 2010, 59 : A291 - A292
  • [32] Exhaled nitric oxide as an accurate and non-invasive test for asthma
    Wechsler, M
    Deykin, A
    Daniel, PE
    Massaro, AF
    Israel, E
    JOURNAL OF ALLERGY AND CLINICAL IMMUNOLOGY, 2002, 109 (01) : S234 - S234
  • [33] Research on the background correction in the non-invasive sensing of glucose by near-infrared spectroscopy
    Liu Rong
    Gu Xiao-yu
    Xu Ke-xin
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2008, 28 (08) : 1772 - 1775
  • [34] Review of process and non-invasive near-infrared and infrared spectroscopy: 1993-1999
    Workman, J.J. Jr.
    Applied Spectroscopy Reviews, 34 (01):
  • [35] Non-alcoholic steatohepatitis: A non-invasive diagnosis by analysis of exhaled breath
    Verdam, Froukje J.
    Dalling, Jan W.
    Driessen, Ann
    de Jonge, Charlotte
    Moonen, Edwin J. C.
    van Berkel, Joep B. N.
    Luijk, Jakobus
    Bouvy, Nicole D.
    Buurman, Wim A.
    Rensen, Sander S.
    Greve, Jan Willem M.
    van Schooten, Frederik Jan
    JOURNAL OF HEPATOLOGY, 2013, 58 (03) : 543 - 548
  • [36] Review of process and non-invasive near-infrared and infrared spectroscopy: 1993-1999
    Workman, JJ
    APPLIED SPECTROSCOPY REVIEWS, 1999, 34 (1-2) : 1 - 89
  • [38] Non-Invasive Glucose Sensing Technologies and Products: A Comprehensive Review for Researchers and Clinicians
    Di Filippo, Daria
    Sunstrum, Frederique N.
    Khan, Jawairia U.
    Welsh, Alec W.
    SENSORS, 2023, 23 (22)
  • [39] Contact lens as an emerging platform for non-invasive bio-sensing: A review
    Shetty, Kiran H.
    Desai, Ditixa T.
    Patel, Hetal P.
    Shah, Dinesh O.
    Willcox, Mark D. P.
    Maulvi, Furqan A.
    SENSORS AND ACTUATORS A-PHYSICAL, 2024, 376
  • [40] Toenail as Non-invasive Biomarker in Metal Toxicity Measurement of Welding Fumes Exposure - A Review
    Bakri, S. F. Z.
    Hariri, A.
    Ma'arop, N. F.
    Hussin, N. S. A. W.
    COLLOQUIUM OF ADVANCED MECHANICS (CAMS2016), 2017, 165