Retrograde Aortic Valve Migration During Transcatheter Aortic Valve Replacement for Aortic Regurgitation: A Case Report Highlighting the Importance of Prompt Venoarterial Extracorporeal Membrane Oxygenation (VA-ECMO) Initiation

被引:0
|
作者
Kitaura, Atsuhiro [1 ]
Sakamoto, Hiroatsu [1 ]
Tsukimoto, Shota [2 ]
Yuasa, Haruyuki [1 ]
Nakajima, Yasufumi [1 ]
机构
[1] Kindai Univ, Fac Med, Anesthesiol, Osaka, Japan
[2] Kanagawa Dent Univ, Dent Anesthesiol, Yokosuka, Japan
关键词
anesthesia; aortic regurgitation; transcatheter aortic valve migration; veno-arterial ecmo; transcatheter aortic valve replacement; IMPLANTATION; EMBOLIZATION;
D O I
10.7759/cureus.62266
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Surgical aortic valve replacement (SAVR) is the recommended curative treatment for pure native aortic regurgitation (AR). However, some patients are not suitable for SAVR due to comorbidities or frailty. Transcatheter aortic valve replacement (TAVR) has been reported to offer a better prognosis than medical therapy in AR patients; thus, the use of TAVR for AR may increase in the future. However, the reduced calcification and annulus ring stiffness associated with TAVR may increase the risk of valve migration. Accumulating data on rescue measures in the event of valve migration is necessary. An 87 -year -old female with a history of hypertension and persistent atrial fibrillation presented to our emergency department with dyspnea. The patient was diagnosed with congestive heart failure class IV, according to the New York Heart Association classification, necessitating urgent admission to our cardiac department. Due to the patient's high surgical risk (Society of Thoracic Surgeons (STS) score 9.17%, Euro2 score 9.55%, frailty 6), the heart team performed TAVR with a right femoral arterial approach. The patient was sedated, and pacing was initiated at 180 bpm. We placed an Edwards SAPIEN 3 valve (Edwards Lifesciences, Irvine, CA, USA) #23 (-1 mL volume, with attached balloon). During the post -deployment procedure, the aortic valve migrated retrogradely into the left ventricle (LV). Despite the occurrence of severe aortic valve regurgitation, the patient's vital signs remained stable. Five minutes after the migration of the aortic valve, venoarterial extracorporeal membrane oxygenation (VA-ECMO) was initiated. A second TAVR valve implantation was then performed. However, after the second valve implantation and the removal of the pre -shaped guidewire (Safari 2 pre -shaped guidewire extra small, Boston Scientific, Marlborough, MA, USA), the migrated valve became stuck in the left ventricular outflow tract (LVOT) in a reverse position, resulting in severely limited left ventricular ejection. We increased the support provided by VA-ECMO, and surgical conversion to SAVR was performed without experiencing circulatory collapse. Surgical aortic valve replacement was initiated successfully, and withdrawal of the cardiopulmonary bypass (CPB) was performed without complications. The patient was extubated on the first postoperative day (POD), discharged from the ICU on POD 3, and transferred for rehabilitation on POD 27. In summary, the prompt introduction of VA-ECMO was important for avoiding complications and saving the patient's life following the retrograde migration of the TAVR valve.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] Catheter Insertion via Extracorporeal Membrane Oxygenation Cannula during Transcatheter Aortic Valve Implantation
    Kuhn, Elmar W.
    Madershahian, Navid
    Rudolph, Tanja K.
    Scherner, Maximilian
    Choi, Yeong-Hoon
    Wahlers, Thorsten
    THORACIC AND CARDIOVASCULAR SURGEON REPORTS, 2016, 5 (01): : 41 - 43
  • [32] Transaxillary Transcatheter Aortic Valve Replacement in a Patient With Previous Aortic Valve-Sparing Root Replacement: A Case Report
    EL-Andari, Ryaan
    Bozso, Sabin J.
    Kang, Jimmy J. H.
    Baghaffar, Abdullah
    Berube, Joel
    Moon, Michael C.
    Tyrrell, Benjamin D.
    Mathew, Anoop
    Welsh, Robert C.
    Nagendran, Jeevan
    CJC OPEN, 2023, 5 (03) : 233 - 236
  • [33] Emergency transcatheter aortic valve implantation with a self-expandable valve under extracorporeal membrane oxygenation for cardiogenic shock due to bicuspid aortic stenosis: a case report
    Osawa, Takumi
    Watabe, Hiroaki
    Hoshi, Tomoya
    Ieda, Masaki
    EUROPEAN HEART JOURNAL-CASE REPORTS, 2023, 7 (07)
  • [34] Urgent Transcatheter Mitral Valve-in-Valve Replacement With Venoarterial Extracorporeal Membrane Oxygenation Support: Case Report and Review of the Literature
    Jawad, Mohammad Abdel
    Munguti, Cyrus M.
    Abu Kar, Abdullah
    Boppana, Venkata
    Fanari, Zaher
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2024, 16 (01)
  • [35] A case report: transfemoral transcatheter aortic valve replacement with a dedicated valve system for severe aortic regurgitation in a patient with a left ventricular assist device
    Goncharov, Arseniy
    Fox, Henrik
    Bleiziffer, Sabine
    Rudolph, Tanja K.
    EUROPEAN HEART JOURNAL-CASE REPORTS, 2023, 7 (06)
  • [36] QUADRICUSPID AORTIC-VALVE WITH SIGNIFICANT REGURGITATION TREATED BY AORTIC-VALVE REPLACEMENT - CASE-REPORT
    MORISHITA, Y
    ISHIZAKI, N
    HASHIGUCHI, M
    FUKUDA, S
    MORIYAMA, Y
    KAWASHIMA, S
    TAIRA, A
    VASCULAR SURGERY, 1988, 22 (04): : 258 - 262
  • [37] Transcatheter aortic valve implantation in a cancer patient denied for surgical aortic valve replacement-a case report
    Mrak, Miha
    Ambrozic, Jana
    Music, Spela
    Terseglav, Simon
    Kontestabile, Bojan
    Lakic, Nikola
    Bunc, Matjaz
    WIENER KLINISCHE WOCHENSCHRIFT, 2016, 128 (13-14) : 516 - 520
  • [38] Successful transcatheter aortic valve replacement in a failing HAART 300 aortic valve annuloplasty ring: A case report
    Abdel-Razek, Omar
    El Khoury, Alessandro
    McGrail, Daniel
    Laham, Roger J.
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2024, 104 (03) : 629 - 632
  • [39] Early stabilization of traumatic aortic transection and mitral valve regurgitation with extracorporeal membrane oxygenation
    Lambrechts, DL
    Wellens, F
    Vercoutere, RA
    De Geest, R
    TEXAS HEART INSTITUTE JOURNAL, 2003, 30 (01) : 65 - 67
  • [40] Extracorporeal Membrane Oxygenation for Very High-risk Transcatheter Aortic Valve Implantation
    Seco, Michael
    Forrest, Paul
    Jackson, Simon A.
    Martinez, Gonzalo
    Andvik, Sarah
    Bannon, Paul G.
    Ng, Martin
    Fraser, John F.
    Wilson, Michael K.
    Vallely, Michael P.
    HEART LUNG AND CIRCULATION, 2014, 23 (10): : 957 - 962