Multi-center safety and efficacy study of a negative-pressure intraoral device in obstructive sleep apnea

被引:1
|
作者
Nilius, Georg [1 ,2 ]
Farid-Moayer, Mehran [3 ]
Lin, Chia-Mo [4 ]
Knaack, Lennart [5 ]
Wang, Ying-Piao [6 ]
Dellweg, Dominic [7 ]
Stoohs, Ricardo [8 ]
Ficker, Joachim [9 ]
Randerath, Winfried [10 ]
Specht, Markus B. [11 ]
Galetke, Wolfgang [12 ]
Schneider, Hartmut [13 ]
机构
[1] Knappschaft gGmbH, Kliniken Essen Mitte, Evang Huyssens Stiftung, Essen Mitte, Germany
[2] Univ Witten Herdecke, Witten, Germany
[3] Peninsula Sleep Ctr, Burlingame, CA USA
[4] Shin Kong Wu Ho Su Mem Hosp, Taipei, Taiwan
[5] Uniklin Koln, Cologne, Germany
[6] Mackay Mem Hosp, Taipei Branch, Taipei, Taiwan
[7] Fachkrankenhaus Kloster Grafschaft GmbH, Schmallenberg, Germany
[8] Somnolab Schlaflabor, Dortmund, Germany
[9] Paracelsus Med Univ, Med Dept Resp Med 3, Klinikum Nuernberg, Nurnberg, Germany
[10] Krankenhaus Bethanien, Solingen, Germany
[11] Zentrum Interdisziplinnare Schlafmed, DKD Wiesbaden, Wiesbaden, Germany
[12] HELIOS Klin Hagen, Hagen, Germany
[13] Amer Sleep Clin, Frankfurt, Germany
关键词
Obstructive sleep apnea; Oral appliance treatment; Sher criteria; POSITIVE AIRWAY PRESSURE; ALL-CAUSE MORTALITY; THERAPY; OBESITY; ADULTS;
D O I
10.1016/j.sleep.2024.04.015
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Background: Intraoral devices, with or without negative oral pressure, can stabilize the oropharynx and reduce obstructive sleep apneas. We tested the hypothesis that treatment with the iNAP (R) Sleep Therapy System, which applies negative oral pressure through an intra-oral appliance, would reduce the severity of obstructive sleep apnea in a multi -center, prospective, first -night -randomized -order cross -over study. Methods/patients: 130 patients fulfilled the entry criteria (age <75, AHI 15 -55, BMI <33), and 63 entered the primary endpoint cohort (Total Sleep Time >= 4 h/night on the baseline polysomnogram and an oral negative vacuum time maintained by iNAP (R) >= 4 h/night and total sleep time >= 4 h/night during the first treatment study). 54 patients completed a second treatment sleep study at least 28 days after the first sleep study. Results: Among the primary endpoint cohort (n = 63, age = 53.2 +/- 11.3, BMI = 27.1 +/- 2.8), 33 patients (52 %; 95 % confidence interval = 40% -64 %, p < 0.001) responded to iNAP treatment according to the Sher criteria ( >50 % reduction in AHI and an AHI <= 20 events/hr). The average oxy-hemoglobin saturation increased by 1 -2%, and the average percent oxygen desaturation decreased (was less severe) by 1 % while using the iNAP device. The incidence of adverse events, all self -limited, was low. The reduction in the apnea-hypopnea index was durable over the 28 -day study. Patients used iNAP on average 5.6 h per night during the study period. Conclusion: The iNAP (R) Sleep Therapy System achieved a durable benefit in more than half the patients with moderate to severe obstructive sleep apnea and may be considered in patients who object to or failed continuous positive airway pressure. Clinical trial registration: ClinicalTrials.gov Identifier: NCT02698059.
引用
收藏
页码:139 / 146
页数:8
相关论文
共 50 条
  • [21] The Efficacy of a Titrated Tongue Stabilizing Device on Obstructive Sleep Apnea
    Alshhrani, W.
    Okuno, K.
    Kohzuka, Y.
    Hamoda, M.
    Peres, B. U.
    Fleetham, J. A.
    Ayas, N.
    Comey, R.
    Almeida, F. R.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2018, 197
  • [22] Remote monitoring system to support positive airway pressure therapy in patients with obstructive sleep apnea: a multi-center randomized controlled trial
    Aalaei, Shokoufeh
    Tabesh, Hamed
    Shahraki, Hadi
    Rezaeitalab, Fariborz
    Amini, Mahnaz
    Afsharisaleh, Lahya
    Asadpour, Hadi
    Eslami, Saeid
    SLEEP AND BREATHING, 2024, 28 (06) : 2759 - 2773
  • [23] TREATMENT OF OBSTRUCTIVE SLEEP APNEA WITH CONTINUOUS NEGATIVE EXTERNAL PRESSURE
    Blackman, Adam
    MacFarlane, James
    Rose, Richard
    SLEEP, 2019, 42
  • [24] OBSTRUCTIVE SLEEP-APNEA COMPLICATING NEGATIVE-PRESSURE VENTILATORY SUPPORT IN PATIENTS WITH CHRONIC PARALYTIC RESTRICTIVE VENTILATORY DYSFUNCTION
    BACH, JR
    PENEK, J
    CHEST, 1991, 99 (06) : 1386 - 1393
  • [25] Evaluation of the safety and efficacy of eszopiclone in patients with obstructive sleep apnea
    Rosenberg, R
    Scharf, M
    Wilson, P
    Roach, J
    SLEEP, 2005, 28 : A154 - A154
  • [26] Efficacy of the NOA® mandibular advancement device in the management of obstructive sleep apnea: A cohort study
    Fernandez-Vial, Diego
    Boggero, Ian
    Pasha, Sara
    Yanez-Regonesi, Fernanda
    Vazquez-Delgado, Eduardo
    Okeson, Jeffrey
    Moreno-Hay, Isabel
    CRANIO-THE JOURNAL OF CRANIOMANDIBULAR & SLEEP PRACTICE, 2025,
  • [27] Efficacy and safety of empiric continuous positive airway pressure therapy in subjects with obstructive sleep APNEA
    Skomro, RP
    King, L
    Mink, J
    CHEST, 2003, 124 (04) : 227S - 227S
  • [28] Study of a Novel Device for the Treatment of Obstructive Sleep Apnea
    Armitstead, J. P.
    Wimms, A. J.
    Bateman, P. E.
    Benjafield, A. V.
    Richards, G. N.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2010, 181
  • [29] Safety and Efficacy of Pediatric Endosonography: A Multi-Center Retrospective Cohort Study
    Akiki, Karl
    Canakis, Andrew
    Mahmoud, Tala
    Alqaisieh, Mohammad H.
    Abu Dayyeh, Barham
    Chandrasekhara, Vinay
    Law, Ryan
    Levy, Michael J.
    Martin, John A.
    Petersen, Bret T.
    Vargas, Eric J.
    Gleeson, Ferga C.
    Rajan, Elizabeth
    Bofill-Garcia, Aliana M.
    Hassan, Sara
    Kim, Raymond E.
    Storm, Andrew C.
    AMERICAN JOURNAL OF GASTROENTEROLOGY, 2022, 117 (10): : S815 - S816
  • [30] Safety and efficacy of fistula closure by endoscopic suturing: a multi-center study
    Mukewar, Saurabh
    Kumar, Nitin
    Catalano, Marc
    Thompson, Christopher
    Abidi, Wasif
    Harmsen, William
    Enders, Felicity
    Gostout, Christopher
    ENDOSCOPY, 2016, 48 (11) : 1023 - 1028