Multi-center safety and efficacy study of a negative-pressure intraoral device in obstructive sleep apnea

被引:1
|
作者
Nilius, Georg [1 ,2 ]
Farid-Moayer, Mehran [3 ]
Lin, Chia-Mo [4 ]
Knaack, Lennart [5 ]
Wang, Ying-Piao [6 ]
Dellweg, Dominic [7 ]
Stoohs, Ricardo [8 ]
Ficker, Joachim [9 ]
Randerath, Winfried [10 ]
Specht, Markus B. [11 ]
Galetke, Wolfgang [12 ]
Schneider, Hartmut [13 ]
机构
[1] Knappschaft gGmbH, Kliniken Essen Mitte, Evang Huyssens Stiftung, Essen Mitte, Germany
[2] Univ Witten Herdecke, Witten, Germany
[3] Peninsula Sleep Ctr, Burlingame, CA USA
[4] Shin Kong Wu Ho Su Mem Hosp, Taipei, Taiwan
[5] Uniklin Koln, Cologne, Germany
[6] Mackay Mem Hosp, Taipei Branch, Taipei, Taiwan
[7] Fachkrankenhaus Kloster Grafschaft GmbH, Schmallenberg, Germany
[8] Somnolab Schlaflabor, Dortmund, Germany
[9] Paracelsus Med Univ, Med Dept Resp Med 3, Klinikum Nuernberg, Nurnberg, Germany
[10] Krankenhaus Bethanien, Solingen, Germany
[11] Zentrum Interdisziplinnare Schlafmed, DKD Wiesbaden, Wiesbaden, Germany
[12] HELIOS Klin Hagen, Hagen, Germany
[13] Amer Sleep Clin, Frankfurt, Germany
关键词
Obstructive sleep apnea; Oral appliance treatment; Sher criteria; POSITIVE AIRWAY PRESSURE; ALL-CAUSE MORTALITY; THERAPY; OBESITY; ADULTS;
D O I
10.1016/j.sleep.2024.04.015
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Background: Intraoral devices, with or without negative oral pressure, can stabilize the oropharynx and reduce obstructive sleep apneas. We tested the hypothesis that treatment with the iNAP (R) Sleep Therapy System, which applies negative oral pressure through an intra-oral appliance, would reduce the severity of obstructive sleep apnea in a multi -center, prospective, first -night -randomized -order cross -over study. Methods/patients: 130 patients fulfilled the entry criteria (age <75, AHI 15 -55, BMI <33), and 63 entered the primary endpoint cohort (Total Sleep Time >= 4 h/night on the baseline polysomnogram and an oral negative vacuum time maintained by iNAP (R) >= 4 h/night and total sleep time >= 4 h/night during the first treatment study). 54 patients completed a second treatment sleep study at least 28 days after the first sleep study. Results: Among the primary endpoint cohort (n = 63, age = 53.2 +/- 11.3, BMI = 27.1 +/- 2.8), 33 patients (52 %; 95 % confidence interval = 40% -64 %, p < 0.001) responded to iNAP treatment according to the Sher criteria ( >50 % reduction in AHI and an AHI <= 20 events/hr). The average oxy-hemoglobin saturation increased by 1 -2%, and the average percent oxygen desaturation decreased (was less severe) by 1 % while using the iNAP device. The incidence of adverse events, all self -limited, was low. The reduction in the apnea-hypopnea index was durable over the 28 -day study. Patients used iNAP on average 5.6 h per night during the study period. Conclusion: The iNAP (R) Sleep Therapy System achieved a durable benefit in more than half the patients with moderate to severe obstructive sleep apnea and may be considered in patients who object to or failed continuous positive airway pressure. Clinical trial registration: ClinicalTrials.gov Identifier: NCT02698059.
引用
收藏
页码:139 / 146
页数:8
相关论文
共 50 条
  • [1] Evaluation of efficacy and safety of intraoral negative air pressure device in adults with obstructive sleep apnea in Taiwan
    Cheng, Ching-Yuan
    Chen, Chia-Chi
    Lo, Men-Tzung
    Guilleminault, Christian
    Lin, Chia-Mo
    SLEEP MEDICINE, 2021, 81 : 163 - 168
  • [2] Safety and effectiveness of intraoral pressure gradient device for obstructive sleep apnea patients
    Liu, T.
    Hsieh, W.
    Chen, B.
    Su, W.
    SLEEP MEDICINE, 2015, 16 : S181 - S181
  • [3] A SINGLE CENTER CROSS-OVER AND EVALUATOR-BLIND PIVOTAL STUDY TO EVALUATE THE EFFICACY AND SAFETY OF INTRAORAL NEGATIVE AIR PRESSURE DEVICE IN ADULTS WITH OBSTRUCTIVE SLEEP APNEA
    Lin, Chia Mo
    Cheng, Ching-Yuan
    Guilleminault, Christian
    SLEEP, 2019, 42
  • [4] Negative-pressure pulmonary Hemorrhaging Due to Severe Obstructive Sleep Apnea
    Kuramoto, Kenya
    Matsuyama, Masashi
    Nonaka, Mizu
    Takeishi, Takahiro
    Oshima, Hisayuki
    Matsumura, Sosuke
    Nakajima, Masayuki
    Sakai, Chio
    Shiozawa, Toshihiro
    Kiwamoto, Takumi
    Tsukahara, Yuko
    Takayashiki, Norio
    Ogawa, Ryoko
    Morishima, Yuko
    Noguchi, Masayuki
    Hizawa, Nobuyuki
    INTERNAL MEDICINE, 2021, 60 (14) : 2291 - 2296
  • [5] EFFICACY OF DENTAL DEVICE FOR TREATMENT FOR MODERATE TO SEVERE OBSTRUCTIVE SLEEP APNEA IN KOREAN: INTERIM RESULT OF PROSPECTIVE MULTI-CENTER STUDY.
    Shin, Y.
    Byun, J.
    Ahn, S.
    Yang, K.
    Cho, Y.
    Shin, W.
    SLEEP, 2018, 41 : A207 - A207
  • [6] Relationship of daytime blood pressure and severity of obstructive sleep apnea among Chinese: a multi-center investigation in China
    He Quan-ying
    Feng Jing
    Zhang Xi-long
    Liang Zong-an
    Huang Shao-guang
    Kang Jian
    Wang Guang-fa
    Zhang Li-qiang
    Ma Li-jun
    Wang Bei
    Lin Qi-chang
    Zhang Jing-nong
    Liu Hui-guo
    Luo Yuan-ming
    Liu Jian-hong
    Wang Shi
    Xiao Gao-hui
    Lu Gan
    Zhang Jin
    Feng Xue-wei
    Chen Bao-yuan
    CHINESE MEDICAL JOURNAL, 2010, 123 (01) : 18 - 22
  • [7] A STUDY TO DETERMINE EFFICACY OF A DEVICE IN ANTICIPATING OBSTRUCTIVE SLEEP APNEA EVENTS
    Rechul, D.
    Rechul, K.
    SLEEP, 2020, 43 : A269 - A270
  • [8] INDUCTION OF SLEEP-APNEA WITH NEGATIVE-PRESSURE VENTILATION IN PATIENTS WITH CHRONIC OBSTRUCTIVE LUNG-DISEASE
    LEVY, RD
    COSIO, MG
    GIBBONS, L
    MACKLEM, PT
    MARTIN, JG
    THORAX, 1992, 47 (08) : 612 - 615
  • [9] Safety and Efficacy of the COHEREX FLATSTENT™ Patent Foramen Ovale Closure Device: A Multi-center Study
    Ruygrok, Peter
    Sievert, Horst
    Schoefer, Joachim
    Grube, Eberhard
    Meier, Bernhard
    Muller, David
    Greaves, Sally
    Edwards, Mark
    Wunderlich, Nina
    AMERICAN JOURNAL OF CARDIOLOGY, 2009, 104 (6A): : 29D - 29D
  • [10] MULTI-CENTER STUDY FOR THE SAFETY AND EFFICACY OF FACIAL PROCEDURES USING A RADIOFREQUENCY DEVICE WITH TEMPERATURE REGULATION
    Saluja, Raminder K.
    Doherty, Sean T.
    LASERS IN SURGERY AND MEDICINE, 2018, 50 (04) : 372 - 372