Adverse Metal Reaction in a Case of Metal-on-Polyethylene Hip Arthroplasty

被引:0
|
作者
Singh, Nikhil [1 ]
Awasthi, Abhiram [1 ]
Pisulkar, Gajanan [1 ]
Taywade, Shounak [1 ]
Samal, Nitin [1 ]
机构
[1] Jawaharlal Nehru Med Coll, Dept Orthopaed Surg, Wardha, India
关键词
metallurgy; revision joint replacement; hip joint; adverse reaction to metal debris; total hip replacement (thr); TISSUE-REACTIONS; REVISION;
D O I
10.7759/cureus.60810
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Soft tissue inflammatory responses to metal debris from prostheses, categorised as adverse reactions to metal debris (ARMD), are frequent complications of total hip arthroplasty (THA) and often result in implant failure. Introducing modular implant designs in modern orthopaedics has brought benefits to total hip replacements but has also increased patients' susceptibility to corrosion-related risks. ARMD can develop from various metal articulating surfaces, including ceramic-on-polyethylene (CoP), ceramic-on-ceramic (CoC), metal-on-metal (MoM), and metal-on-polyethylene (MoP) configurations. In this case study, a 68year-old male who underwent a MoP implant for osteoarthritis of the right hip 16 years ago presented with pain and difficulty walking, exacerbated over the past three months. Clinical examination revealed tenderness around the implant and a limited range of motion. Imaging studies, including X-rays and ultrasound-guided aspiration, coupled with normal serum and urinary cobalt (Co) and chromium (Cr) levels, confirmed the diagnosis of ARMD. Given the severity of symptoms and radiographic findings, surgical intervention was warranted, leading to a two-stage revision with implant augmentation using a BurchSchneider cage. Three months post operation, the patient experienced significant improvements in pain levels, range of motion (ROM), and hip function. This case underscores the importance of vigilant surveillance for ARMD in patients undergoing non-MoM THA, even years post surgery. Prompt recognition and management of ARMD are crucial to mitigate the risk of long-term complications and optimise patient outcomes. Further research is needed to understand the risk factors and mechanisms underlying ARMD in MoP THA, aiding in developing preventive strategies and refined treatment protocols.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Adverse reaction to metal release from a modular metal-on-polyethylene hip prosthesis
    Lindgren, J. U.
    Brismar, B. H.
    Wikstrom, A. C.
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2011, 93B (10): : 1427 - 1430
  • [2] Outcome of Re-Revision Surgery for Adverse Local Tissue Reaction in Metal-on-Polyethylene and Metal-on-Metal Total Hip Arthroplasty
    Bonner, Bryant
    Arauz, Paul
    Klemt, Christian
    Kwon, Young-Min
    [J]. JOURNAL OF ARTHROPLASTY, 2020, 35 (06): : S284 - S288
  • [3] Metal-on-metal versus metal-on-polyethylene bearings in total hip arthroplasty
    Naudie, D
    Roeder, CP
    Parvizi, J
    Berry, DJ
    Eggli, S
    Busato, A
    [J]. JOURNAL OF ARTHROPLASTY, 2004, 19 (07): : 35 - 41
  • [4] Pseudotumor Associated With Metal-on-Polyethylene Total Hip Arthroplasty
    Scully, Cpt William F.
    Teeny, Steven M.
    [J]. ORTHOPEDICS, 2013, 36 (05) : E666 - E670
  • [5] MRI, Retrieval Analysis, and Histologic Evaluation of Adverse Local Tissue Reaction in Metal-on-Polyethylene Total Hip Arthroplasty
    Nodzo, Scott R.
    Esposito, Christina I.
    Potter, Hollis G.
    Ranawat, Chitranjan S.
    Wright, Timothy M.
    Padgett, Douglas E.
    [J]. JOURNAL OF ARTHROPLASTY, 2017, 32 (05): : 1647 - 1653
  • [6] Perfusion MRI in hips with metal-on-metal and metal-on-polyethylene total hip arthroplasty
    Anwander, H.
    Cron, G. O.
    Rakhra, K.
    Beaule, P. E.
    [J]. BONE & JOINT RESEARCH, 2016, 5 (03): : 73 - 79
  • [7] In vivo comparison of hip separation after metal-on-metal or metal-on-polyethylene total hip arthroplasty
    Komistek, RD
    Dennis, DA
    Ochoa, JA
    Haas, BD
    Hammill, C
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2002, 84A (10): : 1836 - 1841
  • [8] Trunnionosis in Metal-on-Polyethylene Total Hip Arthroplasty With Periprosthetic Infection: A Case Report
    Kobayashi, Fumito
    Oe, Kenichi
    Sogawa, Shohei
    Nakamura, Tomohisa
    Saito, Takanori
    [J]. CUREUS JOURNAL OF MEDICAL SCIENCE, 2023, 15 (11)
  • [9] Metal-on-Metal Compared With Metal-on-Polyethylene: The Effect on Trunnion Corrosion in Total Hip Arthroplasty
    Lanting, Brent A.
    Teeter, Matthew G.
    Howard, James L.
    MacDonald, Steven J.
    Van Citters, Douglas W.
    [J]. JOURNAL OF ARTHROPLASTY, 2017, 32 (08): : 2574 - 2579
  • [10] Serum Metal Levels for Diagnosis of Adverse Local Tissue Reactions Secondary to Corrosion in Metal-on-Polyethylene Total Hip Arthroplasty
    Fillingham, Yale A.
    Della Valle, Craig J.
    Bohl, Daniel D.
    Kelly, Mick P.
    Hall, Deborah J.
    Pourzal, Robin
    Jacobs, Joshua J.