Heat Transfer Improvement of Prismatic Lithium-Ion Batteries via a Mini-Channel Liquid-Cooling Plate With Vortex Generators

被引:0
|
作者
Xu, Huanwei [1 ]
Xiong, Shizhe [1 ]
Li, Wei [2 ]
Wu, Lingfeng [1 ]
Wang, Zhonglai [1 ]
机构
[1] Univ Elect Sci & Technol China, Sch Mech & Elect Engn, Chengdu 611731, Peoples R China
[2] Hefei Univ Technol, Sch Mech Engn, Hefei 230009, Peoples R China
基金
中国国家自然科学基金;
关键词
electric vehicle; prismatic batteries; thermal management system; mini-channel cooling plate; vortex generator; THERMAL MANAGEMENT-SYSTEM; PHASE-CHANGE MATERIAL; DESIGN OPTIMIZATION; PERFORMANCE;
D O I
10.1115/1.4063324
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
Temperature is a critical factor affecting the performance and safety of battery packs of electric vehicles (EVs). The design of liquid cooling plates based on mini-channels has always been the research hotspots of battery thermal management systems (BTMS). This paper investigates the effect of adding vortex generators (VGs) to the liquid cooling channel on the heat dissipation capacity and temperature uniformity of the battery. The shape of the vortex generators (triangle, trapezoid, and semicircle), placement position (middle, inlet, and outlet of the channel), different flowrates, and different numbers of channels on the heat dissipation of the battery are systematically analyzed. The research results indicate that (1) compared to the triangular and trapezoidal vortex generators, the semicircular vortex generators have a lower cost in terms of pressure drop while maintaining the same heat dissipation efficiency. The pressure drop of the semicircular vortex generators is 15.89% less than that of the trapezoidal vortex generators and 20.49% less than that of the triangular vortex generators. (2) The effect of adding vortex generators is more obvious when the flowrate is small in the cooling channels. When the flow velocity is 0.025 m/s, the heat dissipation performance can be increased by 7.4%. (3) When the cross-sectional area of the inlet is fixed, the heat dissipation effect of more channels is better. The average temperature of three and seven cooling channels decreases from 311.23 K to 310.07 K, with a decrease of 8.87%. (4) The temperature difference can be effectively reduced when the vortex generators are concentrated near the outlet of the flow outlet. Its temperature difference is 1.8 K lower than that when the vortex generators are placed near the inlet, with a decrease of 10.5%.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] Effective Heat Dissipation for Prismatic Lithium-ion Battery by Fluorinated Liquid Immersion Cooling Approach
    Li, Yang
    Bai, Minli
    Gao, Linsong
    Yang, Yunjie
    Li, Yulong
    Li, Yubai
    Song, Yongchen
    INTERNATIONAL JOURNAL OF GREEN ENERGY, 2024, 21 (02) : 244 - 255
  • [22] Enhancing thermal stability in prismatic lithium-ion battery pack in electric vehicle through optimization for an indirect liquid-cooling system
    Park, Cheonha
    Lee, Jun
    Lee, Hamin
    Chang, Hyukkyun
    Kim, Chang-Wan
    JOURNAL OF COMPUTATIONAL DESIGN AND ENGINEERING, 2025, 12 (03) : 51 - 64
  • [23] Parametric investigation to optimize the thermal management of pouch type lithium-ion batteries with mini-channel cold plates
    Monika, Kokkula
    Chakraborty, Chanchal
    Roy, Sounak
    Dinda, Srikanta
    Singh, Satyapaul A.
    Datta, Santanu Prasad
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2021, 164
  • [24] Parametric investigation to optimize the thermal management of pouch type lithium-ion batteries with mini-channel cold plates
    Monika, Kokkula
    Chakraborty, Chanchal
    Roy, Sounak
    Dinda, Srikanta
    Singh, Satyapaul A.
    Datta, Santanu Prasad
    International Journal of Heat and Mass Transfer, 2021, 164
  • [25] A comprehensive analysis and optimization process for an integrated liquid cooling plate for a prismatic lithium-ion battery module
    Chen, Siqi
    Peng, Xiongbin
    Bao, Nengsheng
    Garg, Akhil
    APPLIED THERMAL ENGINEERING, 2019, 156 : 324 - 339
  • [26] Conjugate heat transfer analysis of mist-assisted film cooling of a mini-channel embedded flat plate
    Jaiswal, Ajay Kumar
    Rao, P. Mallikarjuna
    Mahapatra, Pallab Sinha
    INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2024, 159
  • [27] Numerical optimization of the cooling effect of a bionic fishbone channel liquid cooling plate for a large prismatic lithium-ion battery pack with high discharge rate
    Fan, Xu
    Meng, Chao
    Yang, Yawen
    Lin, Jiashen
    Li, Wanyou
    Zhao, Yingru
    Xie, Shan
    Jiang, Chenxing
    JOURNAL OF ENERGY STORAGE, 2023, 72
  • [28] EXPERIMENTAL INVESTIGATION ON THE HEAT TRANSFER PERFORMANCE OF HEAT PIPES IN COOLING HEV LITHIUM-ION BATTERIES
    Nasir, Faiza M.
    Abdullah, Mohd Z.
    Ismail, Mohd A.
    HEAT TRANSFER RESEARCH, 2018, 49 (17) : 1745 - 1760
  • [29] Effect of Liquid Cooling Structure of Confluence Channel on Thermal Performance of Lithium-Ion Batteries
    Shen, Hengjie
    Li, Minghai
    Wang, Yan
    Wang, Hewu
    Feng, Xuning
    Wang, Juan
    JOURNAL OF ELECTROCHEMICAL ENERGY CONVERSION AND STORAGE, 2024, 21 (01)
  • [30] Mini-channel liquid cooling system for large-sized lithium-ion battery packs by integrating step-allocated coolant scheme
    Wu, Nan
    Li, Xingyao
    Ouyang, Nan
    Zhang, Wencan
    APPLIED THERMAL ENGINEERING, 2022, 214