摘要
Temperature is a critical factor affecting the performance and safety of battery packs of electric vehicles (EVs). The design of liquid cooling plates based on mini-channels has always been the research hotspots of battery thermal management systems (BTMS). This paper investigates the effect of adding vortex generators (VGs) to the liquid cooling channel on the heat dissipation capacity and temperature uniformity of the battery. The shape of the vortex generators (triangle, trapezoid, and semicircle), placement position (middle, inlet, and outlet of the channel), different flowrates, and different numbers of channels on the heat dissipation of the battery are systematically analyzed. The research results indicate that (1) compared to the triangular and trapezoidal vortex generators, the semicircular vortex generators have a lower cost in terms of pressure drop while maintaining the same heat dissipation efficiency. The pressure drop of the semicircular vortex generators is 15.89% less than that of the trapezoidal vortex generators and 20.49% less than that of the triangular vortex generators. (2) The effect of adding vortex generators is more obvious when the flowrate is small in the cooling channels. When the flow velocity is 0.025 m/s, the heat dissipation performance can be increased by 7.4%. (3) When the cross-sectional area of the inlet is fixed, the heat dissipation effect of more channels is better. The average temperature of three and seven cooling channels decreases from 311.23 K to 310.07 K, with a decrease of 8.87%. (4) The temperature difference can be effectively reduced when the vortex generators are concentrated near the outlet of the flow outlet. Its temperature difference is 1.8 K lower than that when the vortex generators are placed near the inlet, with a decrease of 10.5%.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Numerical simulations on hybrid thermal management of mini-channel cold plate and PCM for lithium-ion batteries
    Liu, Yang
    Zhou, Zhifu
    Wu, Wei-Tao
    Wei, Lei
    Li, Yang
    Liu, Xinyu
    Huang, Heng
    Li, Yubai
    Song, Yongchen
    APPLIED THERMAL ENGINEERING, 2024, 250
  • [2] Thermal design and simulation of mini-channel cold plate for water cooled large sized prismatic lithium-ion battery
    Panchal, S.
    Khasow, R.
    Dincer, I.
    Agelin-Chaab, M.
    Fraser, R.
    Fowler, M.
    APPLIED THERMAL ENGINEERING, 2017, 122 : 80 - 90
  • [3] Numerical study of mini-channel liquid cooling for suppressing thermal runaway propagation in a lithium-ion battery pack
    Fu, Hui
    Wang, Junling
    Li, Lun
    Gong, Junhui
    Wang, Xuan
    APPLIED THERMAL ENGINEERING, 2023, 234
  • [4] Thermal performance of cylindrical lithium-ion battery thermal management system integrated with mini-channel liquid cooling and air cooling
    Yang, Wen
    Zhou, Fei
    Zhou, Haobing
    Wang, Qianzhi
    Kong, Jizhou
    APPLIED THERMAL ENGINEERING, 2020, 175
  • [5] A numerical study of a novel centrally bifurcated mini-channel liquid cooling plate for enhanced heat transfer characteristics
    Lv, Youfu
    Liu, Hui
    Luo, Weiming
    Liu, Daifei
    Zhao, Jing
    Wang, Changhong
    Wu, Weixiong
    Rao, Zhonghao
    APPLIED THERMAL ENGINEERING, 2024, 247
  • [6] A double serpentine channel liquid cooling plate for hotspot targeted cooling of lithium-ion batteries in a battery module
    Yogeshwar, Dasari
    Repaka, Ramjee
    Marath, Navaneeth K.
    INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2025, 209
  • [7] The retarding effect of liquid-cooling thermal management on thermal runaway propagation in lithium-ion batteries
    Ke, Qiaomin
    Li, Xin
    Guo, Jian
    Cao, Wenjiong
    Wang, Yiwei
    Jiang, Fangming
    JOURNAL OF ENERGY STORAGE, 2022, 48
  • [8] Thermal performance of lithium-ion battery thermal management system by using mini-channel cooling
    Qian, Zhen
    Li, Yimin
    Rao, Zhonghao
    ENERGY CONVERSION AND MANAGEMENT, 2016, 126 : 622 - 631
  • [9] A Lightweight Multichannel Direct Contact Liquid-Cooling System and Its Optimization for Lithium-Ion Batteries
    Guo, Zhechen
    Xu, Jun
    Xu, Ziming
    Mubashir, Muhammad
    Wang, Haitao
    Mei, Xuesong
    IEEE TRANSACTIONS ON TRANSPORTATION ELECTRIFICATION, 2022, 8 (02) : 2334 - 2345
  • [10] Heat dissipation analysis and optimization of lithium-ion batteries with a novel parallel-spiral serpentine channel liquid cooling plate
    Guo, Rong
    Li, Lu
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2022, 189