The safety of maxillary sinus floor elevation and the accuracy of implant placement using dynamic navigation

被引:0
|
作者
Yang, Miaomiao [1 ]
Ma, Yongqing [2 ]
Han, Wenli [3 ]
Qu, Zhe [1 ]
机构
[1] Dalian Stomatol Hosp, Dept Implantat, Dalian, Liaoning, Peoples R China
[2] Dalian Stomatol Hosp, Dept Oral & Maxillofacial Surg, Dalian, Liaoning, Peoples R China
[3] Dalian Stomatol Hosipital, Radiol Dept, Dalian, Liaoning, Peoples R China
来源
PLOS ONE | 2024年 / 19卷 / 05期
关键词
AUGMENTATION; COMPLICATIONS; PREVALENCE;
D O I
10.1371/journal.pone.0304091
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Objective To date, it remains a challenge to conduct maxillary sinus floor elevation (MSFE) owing to heterogeneity of anatomical structures and limited operative visibility of the maxillary sinus. The aim of this study is to investigate the safety of MSFE and the accuracy of implant placement using dynamic navigation. Methods Forty-two implants were placed in thirty-five patients requiring implantation in posterior maxilla with dynamic navigation. They were assigned to either lateral window sinus floor elevation (LWSFE) group (n = 22) or transcrestal sinus floor elevation (TSFE) group (n = 20) according to the residual alveolar bone height (RBH). Platform deviation, apex deviation and angular deviation between actual and planned implant placement were measured in precision evaluation software. Three deviations of two groups were compared via SPSS 22.0 software. Results Neither accidental bleeding nor perforation of Schneiderian membrane occurred in any patients. The actual window position of LWSFE was consistent with the preoperative design. There were no significant differences in platform, apex and angular deviations between the two groups (P > 0.05). Conclusion In this study the dynamic navigation harvested clinically acceptable safety of MSFE and accuracy for implant placement in posterior maxillary region. The dynamic navigation would provide the clinician with assistance in achieving precise preoperative planning and reducing complications in surgical procedures. The granular bone grafts used in the LWSFE did not significantly affection on the accuracy of the simultaneous implant placement under the guidance of dynamic navigation.
引用
收藏
页数:12
相关论文
共 50 条
  • [31] Dynamic navigation: a prospective clinical trial to evaluate the accuracy of implant placement
    Pellegrino, Gerardo
    Taraschi, Valerio
    Zacchino, Andrea
    Ferri, Agnese
    Marchetti, Claudio
    INTERNATIONAL JOURNAL OF COMPUTERIZED DENTISTRY, 2019, 22 (02) : 139 - 147
  • [32] Displacement of a Dental Implant into the Maxillary Sinus: Report of an Unusual Complication when Performing Staged Sinus Floor Elevation Procedures
    Chappuis, Vivianne
    Suter, Valerie G. A.
    Bornstein, Michael M.
    INTERNATIONAL JOURNAL OF PERIODONTICS & RESTORATIVE DENTISTRY, 2009, 29 (01) : 81 - 87
  • [33] Implant Placement Is More Accurate Using Dynamic Navigation
    Block, Michael S.
    Emery, Robert W.
    Cullum, Daniel R.
    Sheikh, Ali
    JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2017, 75 (07) : 1377 - 1386
  • [34] Endoscope-Assisted Maxillary Sinus Floor Elevation with Platelet-Rich Fibrin Grafting and Simultaneous Implant Placement: A Prospective Clinical Trial
    Wang, Jia
    Sun, Xiaolin
    Lv, Huixin
    Du, Liuyi
    Wang, Lin
    Zhou, Yanmin
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2021, 36 (01) : 137 - 145
  • [35] Maxillary sinus floor elevation without bone grafting using an animal model
    Luo, Zhen
    Zhu, Andi
    Zhang, Di
    Zhong, Huilan
    Yang, Bo
    Huang, Jiansheng
    Xu, Pingping
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2019, 12 (05): : 6283 - 6291
  • [36] Computer guided sinus floor elevation through lateral window approach with simultaneous implant placement
    Osman, Ahmed H.
    Mansour, Hesham
    Atef, Mohammed
    Hakam, Maha
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2018, 20 (02) : 137 - 143
  • [37] Implant placement in fresh extraction sockets and simultaneous osteotome sinus floor elevation: A case series
    Barone, Antonio
    Cornelini, Roberto
    Ciaglia, Renato
    Covani, Ugo
    INTERNATIONAL JOURNAL OF PERIODONTICS & RESTORATIVE DENTISTRY, 2008, 28 (03) : 283 - 290
  • [38] Biomechanical analysis of the maxillary sinus floor membrane during internal sinus floor elevation with implants at different angles of the maxillary sinus angles
    Yinxin Deng
    Ruihong Ma
    Yilin He
    Shujia Yu
    Shiyu Cao
    Kang Gao
    Yiping Dou
    Pan Ma
    International Journal of Implant Dentistry, 10
  • [39] Biomechanical analysis of the maxillary sinus floor membrane during internal sinus floor elevation with implants at different angles of the maxillary sinus angles
    Deng, Yinxin
    Ma, Ruihong
    He, Yilin
    Yu, Shujia
    Cao, Shiyu
    Gao, Kang
    Dou, Yiping
    Ma, Pan
    INTERNATIONAL JOURNAL OF IMPLANT DENTISTRY, 2024, 10 (01)
  • [40] Learning Curve and Comparison of Dynamic Implant Placement Accuracy Using a Navigation System in Young Professionals
    Spille, Johannes
    Helmstetter, Eva
    Kuebel, Paul
    Weitkamp, Jan-Tobias
    Wagner, Juliane
    Wieker, Henning
    Naujokat, Hendrik
    Floerke, Christian
    Wiltfang, Joerg
    Guelses, Aydin
    DENTISTRY JOURNAL, 2022, 10 (10)