Early detection of hypo/hyperglycemia using a microneedle electrode array-based biosensor for glucose ultrasensitive monitoring in interstitial fluid

被引:8
|
作者
Tawakey, Samar H. [1 ,2 ]
Mansour, Mohammad [1 ]
Soltan, Ahmed [1 ]
Salim, Alyaa I. [3 ]
机构
[1] Nile Univ, Nanoelect Integrated Syst Ctr NISC, Giza 12588, Egypt
[2] Tanta Univ, Fac Sci, Chem Dept, Tanta 31527, Egypt
[3] Nile Univ, Sch Biotechnol, Giza 12588, Egypt
关键词
PRINTED CARBON ELECTRODE; GOLD NANOPARTICLES; URIC-ACID; SENSOR; NANOTUBES; OXIDASE; FILMS;
D O I
10.1039/d4lc00365a
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Diabetes is a common chronic metabolic disease with a wide range of clinical symptoms and consequences and one of the main causes of death. For the management of diabetes, painless and continuous interstitial fluid (ISF) glucose monitoring is ideal. Here, we demonstrate continuous diabetes monitoring using an integrated microneedle (MN) biosensor with an emergency alert system. MNs are a novel technique in the field of biomedical engineering because of their ability to analyze bioinformation with minimal invasion. In this work we developed a poly(methyl methacrylate) (PMMA) based MN glucose sensor. The device was produced by the 3D printing technique, microfabrication, electrodeposition, and enzyme immobilization step. The in vitro test for the glucose MN sensor showed a linear range from 1.5 to 14 mM with a sensitivity of 1.51 mu A mM-1, limit of detection (LOD) of 0.35 mM and good selectivity. Highly repeatable sensing is observed with good reproducibility. The interference-free detection of glucose in the presence of physiologically relevant concentrations of ascorbic acid, uric acid, and mannose is demonstrated, along with the operational stability of the array. After resolving the biofouling consequences linked to on-body sensing, this MN platform would be appealing for minimally invasive electrochemical glucose monitoring. An alert is sent to confidants via email or SMS when the values are abnormal. The application is also able to display the recorded values in the form of a graph to help determine the state of health of the user over a period of time. It can be concluded that continuous monitoring and an emergency alert system are important for keeping an eye on diabetic patients and can send alert in case of an abnormal situation of the patient. A fully integrated, high-precision, wearable electrochemical microneedle sensing device that works with a customized smartphone application to wirelessly and in real-time monitor glucose of hypo/hyperglycemia in human ISF.
引用
收藏
页码:3958 / 3972
页数:15
相关论文
共 27 条
  • [21] A minimally invasive sensing system based on hydrogel microneedle patches and Au/Cu2O nanospheres modified screen-printed carbon electrode for glucose monitoring in interstitial skin fluid
    Jin, Dalan
    Xu, Zijing
    Zhao, Hongyi
    Deng, Silang
    Qu, Zhuangzhuang
    Dou, Runye
    Liu, Weilu
    MICROCHEMICAL JOURNAL, 2024, 205
  • [22] Sensitive detection of SARS-CoV-2 spike protein using vertically-oriented silicon nanowire array-based biosensor
    Gao, Bingtao
    Chavez, Roberth Anthony Rojas
    Malkawi, Walla, I
    Keefe, Daniel W.
    Smith, Rasheid
    Haim, Hillel
    Salem, Aliasger K.
    Toor, Fatima
    SENSING AND BIO-SENSING RESEARCH, 2022, 36
  • [23] Rapid and ultrasensitive detection of Salmonella typhimurium using a novel impedance biosensor based on SiO2@MnO2 nanocomposites and interdigitated array microelectrodes
    Wang, Sihan
    Peng, Tao
    Meng, Qingyi
    Zhu, Xiaoli
    Guo, Liuchuan
    Yao, Kai
    Wang, Zheng
    Zheng, Pimiao
    Ren, Zhenhui
    He, Zhiwei
    Zhang, Jing
    Jiang, Haiyang
    SENSORS AND ACTUATORS B-CHEMICAL, 2020, 324
  • [24] A patch type non-enzymatic biosensor based on 3D SUS micro-needle electrode array for minimally invasive continuous glucose monitoring
    Lee, Su Jin
    Yoon, Hyo Sang
    Xuan, Xing
    Park, Jae Y.
    Paik, Seung-Joon
    Allen, Mark G.
    SENSORS AND ACTUATORS B-CHEMICAL, 2016, 222 : 1144 - 1151
  • [25] Ultra-High Sensitivity Silicon Nanowire Array Biosensor Based on a Constant-Current Method for Continuous Real-Time pH and Protein Monitoring in Interstitial Fluid
    Sprunger, Y.
    Capua, L.
    Ernst, T.
    Barraud, S.
    Ionescu, A. M.
    Saeidi, A.
    IEEE 49TH EUROPEAN SOLID STATE CIRCUITS CONFERENCE, ESSCIRC 2023, 2023, : 153 - 156
  • [26] A microfluidic chip using Au@SiO2 array-based highly SERS-active substrates for ultrasensitive detection of dual cervical cancer-related biomarkers
    Gu, Yingyan
    Li, Zhiyue
    Ge, Shengjie
    Mao, Yu
    Gu, Yuexing
    Cao, Xiaowei
    Lu, Dan
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2022, 414 (26) : 7659 - 7673
  • [27] Ultrasensitive electrochemical biosensor based on triple signal amplification strategy for detection of serum cf-miR-181b: A possible biomarker related to osteosarcoma's early diagnosis and chemotherapy monitoring
    Chen, Jin-Yuan
    Wang, Yun-Qing
    Lin, Huang-Feng
    Yu, Lu-Ying
    Lin, Xiu-Zhen
    Lin, Xin-Hua
    Xu, Xiong-Wei
    Lin, Jian-Hua
    Zhong, Guang-Xian
    SENSORS AND ACTUATORS B-CHEMICAL, 2023, 395