摘要
This study presents the development of a Pulse Height Analyzer (PHA) using an FPGA-based hardware platform, specifically the National Instruments MyRIO embedded device, for radiation detectors. Electronic pulses generated by the detector when exposed to radiation are triggered, digitized, and transferred to a data buffer. A pulse height analysis tool categorizes these pulses and stores pulse-height information in registers or channels, enabling the construction of a pulse-height distribution. The data of pulse-height distribution is then recorded on a computer via a user-friendly interface. The Pulse Height Analyzer was implemented using a 3-inch by 3-inch NaI(Tl) scintillation detector for gamma energy measurements, employing standard radioisotopes Na-22 and Co-60. Gamma energy spectra were acquired and analyzed. Our results demonstrate that the achieved energy resolution is comparable to that of the commercial Pulse Height Analyzers, such as EASY-MCA 2K, a product of AMETEK Inc. (c) 2024 Institute of Electrical Engineer of Japan and Wiley Periodicals LLC.
引用
收藏
页码:1737 / 1742
页数:6
相关论文
共 50 条
  • [31] An FPGA-Based Pulse Pile-up Rejection Technique for Photon Counting Imaging Detectors
    胡坤
    李锋
    陈炼
    梁福田
    金革
    Chinese Physics Letters, 2015, 32 (03) : 30 - 33
  • [32] An FPGA-Based Pulse Pile-up Rejection Technique for Photon Counting Imaging Detectors
    胡坤
    李锋
    陈炼
    梁福田
    金革
    Chinese Physics Letters, 2015, (03) : 30 - 33
  • [33] An FPGA-Based Pulse Pile-up Rejection Technique for Photon Counting Imaging Detectors
    Hu Kun
    Li Feng
    Chen Lian
    Liang Fu-Tian
    Jin Ge
    CHINESE PHYSICS LETTERS, 2015, 32 (03)
  • [34] Energy calibration for plastic scintillation detectors based on Compton scatterings of gamma rays
    Li, X.
    Wang, Y.
    Zhou, R.
    Yan, C.
    JOURNAL OF INSTRUMENTATION, 2017, 12
  • [35] Development of FPGA-based digital signal processing system for radiation spectroscopy
    Lee, Pil Soo
    Lee, Chun Sik
    Lee, Ju Hahn
    RADIATION MEASUREMENTS, 2013, 48 : 12 - 17
  • [36] Spatiotemporal Monte Carlo transport methods in x-ray semiconductor detectors: Application to pulse-height spectroscopy in a-Se
    Fang, Yuan
    Badal, Andreu
    Allec, Nicholas
    Karim, Karim S.
    Badano, Aldo
    MEDICAL PHYSICS, 2012, 39 (01) : 308 - 319
  • [37] FPGA-Based Pulse Pile-Up Correction With Energy and Timing Recovery
    Haselman, M. D.
    Pasko, J.
    Hauck, S.
    Lewellen, T. K.
    Miyaoka, R. S.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2012, 59 (05) : 1823 - 1830
  • [38] Pseudo-Gamma Spectroscopy Based on Plastic Scintillation Detectors Using Multitask Learning
    Jeon, Byoungil
    Kim, Junha
    Lee, Eunjoong
    Moon, Myungkook
    Cho, Gyuseong
    SENSORS, 2021, 21 (03) : 1 - 21
  • [39] Use of Pulse-Height Spectroscopy to Characterize the Hole Conduction Mechanism of a Polyimide Blocking Layer Used in Amorphous-Selenium Radiation Detectors
    Camlica, Ahmet
    Kabir, M. Zahangir
    Liang, Jerry
    Levine, Peter M.
    Lee, Denny L.
    Karim, Karim S.
    Camlica, Ahmet (acamlica@uwaterloo.ca), 1600, Institute of Electrical and Electronics Engineers Inc., United States (67): : 633 - 639
  • [40] Cosmic ray angular distribution employing plastic scintillation detectors and flash-ADC/FPGA-based readout systems
    Hai, V. H.
    Dao, N. Q.
    Nomachi, M.
    KERNTECHNIK, 2012, 77 (06) : 462 - 464