A total of 35 cold-formed stainless steel double shear one-bolted and three-bolted connection specimens were tested using transient state test method. The specimens of bolted connections were fabricated by three different grades of stainless steel. The three different grades of stainless steel are austenitic stainless steel EN 1.4301 (AISI 304) and EN 1.4571 (AISI 316Ti having small amount of titanium) as well as lean duplex stainless steel EN 1.4162 (AISI S32101). The connection tests were conducted at three different load levels of 0.25, 0.50 and 0.75 of the failure load at room temperature. The tendency of the test strength reduction of the stainless steel double shear bolted connections conducted using the transient state test method is similar to those results obtained by the steady state test method. However, the critical temperatures obtained from the transient state test results are generally slightly higher compared with those deduced from the steady state test results at the three different load levels. The austenitic stainless steel grade EN 1.4571 generally performed better than the other two stainless steel grades in transient state tests as higher values of critical temperatures were obtained. Two failure modes, namely the bearing and net section tension failures, were observed in the transient state tests.
引用
收藏
页码:1030 / 1035
页数:6
相关论文
共 50 条
  • [41] Behavior of double-shear high strength steel bolted connections at elevated temperatures
    Cho, Yong Hyun
    Teh, Lip H.
    Young, Ben
    ADVANCES IN ENGINEERING MATERIALS, STRUCTURES AND SYSTEMS: INNOVATIONS, MECHANICS AND APPLICATIONS, 2019, : 1266 - 1270
  • [42] Design of Cold-Formed Steel Screw Connections with Gypsum Sheathing at Ambient and Elevated Temperatures
    Chen, Wei
    Ye, Jihong
    Chen, Tao
    APPLIED SCIENCES-BASEL, 2016, 6 (09):
  • [43] EXPERIMENTAL INVESTIGATION ON BOLTED ANGLE CONNECTIONS FOR COLD-FORMED STEEL SECTIONS
    Tan, C. S.
    Tahir, M. M.
    Shek, P. N.
    Proceedings of the 7th International Conference on Steel and Aluminium Structures (ICSAS 2011), 2011, : 186 - 192
  • [44] Seismic Behavior of Cold-Formed Steel Frames with Bolted Moment Connections
    Chen, Ming
    Huo, Jia-Hao
    Xing, Yi-Wen
    JOURNAL OF STRUCTURAL ENGINEERING, 2020, 146 (03)
  • [45] Structural performance of cold-formed lean duplex stainless steel beams at elevated temperatures
    Huang, Yuner
    Young, Ben
    THIN-WALLED STRUCTURES, 2018, 129 : 20 - 27
  • [46] Web crippling tests of cold-formed stainless steel tubular sections at elevated temperatures
    Zhan, Ke-Jiang
    Li, Hai -Ting
    Fan, Zhi-Hao
    Young, Ben
    ENGINEERING STRUCTURES, 2024, 304
  • [47] CONNECTIONS IN COLD-FORMED STEEL
    TOMA, A
    SEDLACEK, G
    WEYNAND, K
    THIN-WALLED STRUCTURES, 1993, 16 (1-4) : 219 - 237
  • [48] Analysis of steel bolted double angle connections at elevated temperatures
    Hantouche, Elie G.
    Abboud, Nabil H.
    Morovat, Mohammed A.
    Engelhardt, Michael D.
    FIRE SAFETY JOURNAL, 2016, 83 : 79 - 89
  • [49] Block shear behaviour and design of cold-formed staggered hole bolted connections
    Pham, Viet Binh
    Pham, Cao Hung
    Hancock, Gregory J.
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2021, 180
  • [50] Screwed connections in built-up cold-formed steel members at ambient and elevated temperatures
    Vy, Son Tung
    Mahendran, Mahen
    Journal of Constructional Steel Research, 2022, 192