Effect of single and double pulse laser-induced breakdown spectroscopy towards steel alloy in different gaseous media

被引:3
|
作者
Alkallas, Fatemah H. [1 ]
Mostafa, Ayman M. [2 ,3 ]
Trabelsi, Amira Ben Gouider [1 ]
Khater, Mohamed A. [3 ]
Motawea, Mariem M. [4 ]
Al-Ahmadi, Ameenah N. [5 ]
Elsharkawy, Wafaa B. [6 ]
Rezk, Reham A. [7 ]
机构
[1] Princess Nourah Bint Abdulrahman Univ, Coll Sci, Dept Phys, POB 84428, Riyadh 11671, Saudi Arabia
[2] Qassim Univ, Coll Sci, Dept Phys, Buraydah 51452, Saudi Arabia
[3] Natl Res Ctr, Phys Res Inst, Spect Dept, 33 El Bohouth St, Giza 12622, Egypt
[4] Univ Bisha, Coll Sci, Dept Chem, Bisha 61922, Saudi Arabia
[5] Umm Al Qura Univ, Fac Sci, Dept Phys, Mecca 24382, Saudi Arabia
[6] Prince Sattam Bin Abdulaziz Univ, Coll Sci & Humanities Studies, Phys Dept, Alkharj 11942, Saudi Arabia
[7] Higher Technol Inst, POB 4,3rd Zone,7th Sect, Giza, Egypt
关键词
Laser -induced breakdown spectroscopy (LIBS); Steel alloy; Different media; Single and double pulse; Optical properties; LIBS; EMISSION; PLASMAS; CU;
D O I
10.1016/j.matchemphys.2024.129443
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
In recent years, laser-induced breakdown spectroscopy (LIBS) technique showed its promising for material analysis, quality control, forensic science, and environmental safety monitoring. Besides, due to its rapid measurement capability and minimal sample-preparation requirements, it is a widely recognized elemental analysis approach used in a variety of study domains. The current work compares spatially resolved single (SP) and double pulse (DP), especially orthogonal DP, setups for LIBS to examine and enhance the limit of detection (LOD) in duplex stainless steels alloy. Using the Boltzmann plot method and the Stark broadening mechanism, the electron temperature and density of local arc plasma are highlighted due to single pulse and orthogonal pre-pulse double pulse configurations. With delay time, the circumstances of arc plasma's local thermodynamic equilibrium (LTE) of emission spectral lines are investigated. The experimental results show that there are significant increases in the spectral intensities of the Fe lines in double pulse LIBS under Ar-gas compared to those under Hegas. Internal standardization was used to create calibration curves for the spectral lines of Cr, Cu, and Mn in the alloy sample for the both studied media. It demonstrated that argon outperforms helium in determining the elemental composition of steel alloys. Furthermore, LOD for SP-LIBS and DP-LIBS in both media were calculated, which showed a higher detection LOD for DP-LIBS in the presence of Ar-gas compared to that in He-gas.
引用
收藏
页数:9
相关论文
共 50 条
  • [31] In situ analysis of magnesium alloy using a standoff and double-pulse laser-induced breakdown spectroscopy system
    辛勇
    孙兰香
    杨志家
    曾鹏
    丛智博
    齐立峰
    Frontiers of Physics, 2016, 11 (05) : 152 - 161
  • [32] Signal Detection of Carbon in Iron-Based Alloy by Double-Pulse Laser-Induced Breakdown Spectroscopy
    林晓梅
    李晗
    姚清华
    Plasma Science and Technology, 2015, (11) : 953 - 957
  • [33] In situ analysis of magnesium alloy using a standoff and double-pulse laser-induced breakdown spectroscopy system
    Xin, Yong
    Sun, Lan-Xiang
    Yang, Zhi-Jia
    Zeng, Peng
    Cong, Zhi-Bo
    Qi, Li-Feng
    FRONTIERS OF PHYSICS, 2016, 11 (05)
  • [34] Analysis of alloy and solar cells with double-pulse calibration-free laser-induced breakdown spectroscopy
    Shakeel, Hira
    Haq, S. U.
    Contreras, Victor
    Abbas, Qamar
    Nadeem, Ali
    OPTIK, 2020, 211
  • [35] Experimental Study on High Alloy Steel Sample by Laser-Induced Breakdown Spectroscopy
    Guo Qian-jin
    Yu Hai-bin
    Xin Yong
    Li Xiao-li
    Li Xian-hong
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2010, 30 (03) : 783 - 787
  • [36] Experimental study on high alloy steel sample by laser-induced breakdown spectroscopy
    Guo Q.-J.
    Yu H.-B.
    Xin Y.
    Li X.-L.
    Li X.-H.
    Guang Pu Xue Yu Guang Pu Fen Xi/Spectroscopy and Spectral Analysis, 2010, 30 (03): : 783 - 787
  • [37] Different calibration strategies to overcome matrix effect in steel analysis by Laser-Induced Breakdown Spectroscopy
    Labutin, Timur A.
    Popov, Andrey M.
    Seliverstova, Irina V.
    Zorov, Nikita B.
    LAT 2010: INTERNATIONAL CONFERENCE ON LASERS, APPLICATIONS, AND TECHNOLOGIES, 2011, 7994
  • [38] Reducing self-absorption effect by double-pulse combination in laser-induced breakdown spectroscopy
    Wang, Wei
    Sun, Lanxiang
    Zhang, Peng
    Zheng, Liming
    Qi, Lifeng
    MICROCHEMICAL JOURNAL, 2022, 172
  • [39] Effect of target composition on the emission enhancement observed in Double-Pulse Laser-Induced Breakdown Spectroscopy
    Cristoforetti, G.
    Legnaioli, S.
    Palleschi, V.
    Salvetti, A.
    Tognoni, E.
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2008, 63 (02) : 312 - 323
  • [40] Effect of parameters on Si plasma emission in collinear double-pulse laser-induced breakdown spectroscopy
    Fang-Fang Chen
    Xue-Jiao Su
    Wei-Dong Zhou
    Frontiers of Physics, 2015, 10