Alveolar Microdynamics during Tidal Ventilation in Live Animals Imaged by SPring-8 Synchrotron

被引:2
|
作者
Kim, Min Woo [1 ,2 ]
Yu, Seung Hyeon [3 ]
Yang, Un [4 ]
Nukiwa, Ryota [5 ]
Cho, Hyeon Jung [1 ]
Kwon, Nam Seop [1 ]
Yong, Moon Jung [4 ]
Kim, Nam Ho [4 ]
Lee, Sang Hyeon [4 ]
Lee, Jun Ho [4 ]
Lim, Jae Hong [2 ]
Kohmura, Yoshiki [6 ]
Ishikawa, Tatsuya [6 ]
Henry, Frank S. [7 ]
Imai, Yumiko [5 ]
Oh, Seung Soo [4 ]
Hwang, Hyung Ju [3 ,11 ]
Tsuda, Akira [8 ,9 ]
Je, Jung Ho [1 ,4 ,10 ]
机构
[1] Pohang Univ Sci & Technol POSTECH, Sch Interdisciplinary Biosci & Bioengn, Pohang 37673, South Korea
[2] POSTECH, Pohang Accelerator Lab PAL, Pohang 37673, South Korea
[3] POSTECH, Dept Math, Pohang 37673, South Korea
[4] POSTECH, Dept Mat Sci & Engn, Pohang 37673, South Korea
[5] Natl Inst Biomed Innovat Hlth & Nutr, Infect Med Informat Lab, Osaka 5670085, Japan
[6] RIKEN SPring 8 Ctr, Sayo, Hyogo 6795148, Japan
[7] Manhattan Coll, Dept Mech Engn, Riverdale, NY 10471 USA
[8] Harvard Sch Publ Hlth, Dept Environm Hlth, Boston, MA 02115 USA
[9] Tsuda Lung Res, Shrewsbury, MA 01545 USA
[10] Nanoblesse Res Lab, Pohang 37883, South Korea
[11] POSTECH, Grad Sch Artificial Intelligence, Pohang 37673, South Korea
基金
新加坡国家研究基金会;
关键词
alveolar ducts; alveolus; gas exchange; lung volume; microdynamics; surface area; synchrotron; LUNG; DYNAMICS; BIOMECHANICS; RESPIRATION; MECHANICS; COLLAGEN; INJURY; RAT;
D O I
10.1002/advs.202306256
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
It is self-evident that our chests expand and contract during breathing but, surprisingly, exactly how individual alveoli change shape over the respiratory cycle is still a matter of debate. Some argue that all the alveoli expand and contract rhythmically. Others claim that the lung volume change is due to groups of alveoli collapsing and reopening during ventilation. Although this question might seem to be an insignificant detail for healthy individuals, it might be a matter of life and death for patients with compromised lungs. Past analyses were based on static post-mortem preparations primarily due to technological limitations, and therefore, by definition, incapable of providing dynamic information. In contrast, this study provides the first comprehensive dynamic data on how the shape of the alveoli changes, and, further, provides valuable insights into the optimal lung volume for efficient gas exchange. It is concluded that alveolar micro-dynamics is nonlinear; and at medium lung volume, alveoli expand more than the ducts. Gas exchange is enhanced when the alveolar volume increases more than the alveolar duct's volume because an increase in alveolar volume increases the surface area available for gas exchange but the ducts do not directly contribute to gas exchange. This study reveals that more air enters the alveolus than the alveolar ducts, showing the highest alveolar wall compliance, in the case of medium lung volume. image
引用
收藏
页数:14
相关论文
共 50 条
  • [31] Test Study for Generation of Short Pulsed Synchrotron Radiation by Kicker Magnet in SPring-8 Storage Ring
    Mitsuda, C.
    Fukami, K.
    Kobayashi, K.
    Masaki, M.
    Mochihashi, A.
    Nakanishi, T.
    Oishi, M.
    Schimizu, J.
    Shimosaki, Y.
    Shoji, M.
    Soutome, K.
    Tamura, K.
    Yonehara, H.
    Ohshima, T.
    SRI 2009: THE 10TH INTERNATIONAL CONFERENCE ON SYNCHROTRON RADIATION INSTRUMENTATION, 2010, 1234 : 197 - +
  • [32] Performance of YB66 double-crystal monochromator for dispersing synchrotron radiation at SPring-8
    Kitamura, M
    Yoshikawa, H
    Mochizuki, T
    Vlaicu, AM
    Nisawa, A
    Yagi, N
    Okui, M
    Kimura, M
    Tanaka, T
    Fukushima, S
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 497 (2-3): : 550 - 562
  • [33] Search for low-energy induced depletion of 178Hfm2 at the SPring-8 synchrotron
    Carroll, J. J.
    Karamian, S. A.
    Propri, R.
    Gohlke, D.
    Caldwell, N.
    Ugorowski, P.
    Drummond, T.
    Lazich, J.
    Roberts, H.
    Helba, M.
    Zhong, Z.
    Tang, M. -T.
    Lee, J. -J.
    Liang, K.
    PHYSICS LETTERS B, 2009, 679 (03) : 203 - 208
  • [34] X-ray diffraction studies of expanded fluid mercury using synchrotron radiation at SPring-8
    Tamura, K
    Inui, M
    Nakaso, I
    Oh'ishi, Y
    Funakoshi, K
    Utsumi, W
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS BRIEF COMMUNICATIONS & REVIEW PAPERS, 1999, 38 : 452 - 455
  • [35] Alveolar albumin leakage during large tidal volume ventilation and surfactant dysfunction
    Liu, JM
    Evander, E
    Zhao, J
    Wollmer, P
    Jonson, B
    CLINICAL PHYSIOLOGY, 2001, 21 (04): : 421 - 427
  • [36] Modular design of multi-wire moderator for slow positron source on hard synchrotron radiation SPring-8
    Nikitin, VP
    Plokhoi, VV
    Doronina, PP
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 470 (1-2): : 50 - 52
  • [37] Extremely High Resolution Single Crystal Diffractometory for Orbital Resolution using High Energy Synchrotron Radiation at SPring-8
    Sugimoto, Kunihisa
    Ohsumi, Hiroyuki
    Aoyagi, Shinobu
    Nishibori, Eiji
    Moriyoshi, Chikako
    Kuroiwa, Yoshihiro
    Sawa, Hiroshi
    Takata, Masaki
    SRI 2009: THE 10TH INTERNATIONAL CONFERENCE ON SYNCHROTRON RADIATION INSTRUMENTATION, 2010, 1234 : 887 - +
  • [38] Study on efficiency of multi-wire tungsten moderator for slow positron source on SPring-8 hard synchrotron radiation
    Plokhoi, V
    Kandiev, Y
    Samarin, S
    Malyshkin, G
    Baidin, G
    Litvinenko, I
    Nikitin, V
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS SHORT NOTES & REVIEW PAPERS, 1999, 38 : 604 - 607
  • [39] Three-dimensional histological analysis of cardiac tissue in experimental small animals by synchrotron radiation-based X-ray phase-contrast imaging at SPring-8
    Hirao, S.
    Masumoto, H.
    Hoshino, M.
    Minakata, K.
    Takimoto, S.
    Ikeda, T.
    Yamashita, J. K.
    Yagi, N.
    Minatoya, K.
    EUROPEAN HEART JOURNAL, 2017, 38 : 692 - 692
  • [40] Generation of high-energy synchrotron radiation with a 10-T superconducting wiggler installed in the SPring-8 storage ring
    Soutome, K
    Daté, S
    Ego, H
    Fukui, T
    Hara, M
    Hosoda, N
    Kawashima, Y
    Kodera, M
    Kumagai, N
    Magome, T
    Masaki, M
    Masuda, T
    Matsui, S
    Nakamura, T
    Noda, T
    Ohashi, Y
    Ohshima, T
    Oishi, M
    Saeki, H
    Sasaki, S
    Shoji, M
    Takano, S
    Takao, M
    Takashima, T
    Takebe, H
    Tamura, K
    Tanaka, H
    Taniuchi, Y
    Tsumaki, K
    Yorita, T
    Zhang, C
    Yonehara, H
    Schimizu, J
    Batrakov, A
    Karpov, G
    Kulipanov, G
    Kuzin, M
    Shkaruba, V
    Skrinsky, A
    Mezentsev, N
    PROCEEDINGS OF THE 2003 PARTICLE ACCELERATOR CONFERENCE, VOLS 1-5, 2003, : 250 - 252