Inconsistencies and False Assumptions Related to the Determination of Design Values for FRP Systems

被引:0
|
作者
Arnold, Scott F. [1 ]
Ortiz, Reymundo [1 ]
机构
[1] Fyfe Co LLC, San Diego, CA 92123 USA
关键词
Fiber reinforced polymer (FRP); Retrofit and rehabilitation; Design properties; ASTM standards; Structural engineering;
D O I
暂无
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Fiber reinforced polymer (FRP) materials have been used for over half a century in the aerospace, marine and automotive industries. During the last few decades, civil and structural engineers have begun to see the advantage of these materials as a means to retrofit and rehabilitate existing structural members in buildings, bridges and other civil infrastructures. There are many guidelines and some codes that help engineers to design these systems for various structural applications. Despite the increase in acceptance of these systems there remains some major confusion related to the most fundamental part of the design process. How do you determine the characteristic values/design properties of the material? Some of the confusion stems from the assumption that all fiber reinforced polymers (FRPs) use the same method to report their design values. they do not. Or that the ASTM standards being used by the industry provide consistent design properties. they do not. Some engineers assume that following CSA S806, CSA S6-06 or ACI 440.2R-17 will get them consistent design properties. it will not. These issues have created confusion, and they have not been appropriately addressed. This paper will point out the various inconsistencies and false assumptions in more detail while presenting a suggested solution that has been in practice in other industries using FRP materials.
引用
收藏
页码:739 / 753
页数:15
相关论文
共 50 条
  • [41] DETERMINATION OF FRICTION VALUES FOR THE DESIGN OF SIDE SLOPES LINED OR PROTECTED WITH GEOSYNTHETICS
    EIGENBROD, KD
    LOCKER, JG
    CANADIAN GEOTECHNICAL JOURNAL, 1987, 24 (04) : 509 - 519
  • [42] Plastic gears for medical technology. Characteristic values determination and design
    Feulner, Robert W.
    Dallner, Claus M.
    Schmachtenberg, Ernst
    Schmidt, Winfried
    Konstruktion, 2007, (SUPPL. 1): : 42 - 47
  • [43] Design of False Data Injection Attacks for Output Tracking Control of CARMA Systems
    Pang, Zhonghua
    Hou, Fangyuan
    Zhou, Yuguo
    Sun, Dehui
    2015 IEEE INTERNATIONAL CONFERENCE ON INFORMATION AND AUTOMATION, 2015, : 1273 - 1277
  • [44] Determination of instantaneous values of flow rate of fuel in cyclic injection systems
    Polyaev, VM
    Ismailov, MM
    Yudin, DY
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 1998, 41 (04) : 582 - 586
  • [45] New Durability Concept for FRP Reinforcing Bars: Combined durability and creep rupture testing allows for realistic design values
    Weber, André
    Baquero, Christian Witt
    Concrete International, 2010, 32 (07) : 49 - 53
  • [46] DETERMINATION OF CLINICAL CHARACTERISTICS FOR MEN ON ADT AS RELATED TO BASELINE SERUM TESTOSTERONE VALUES
    Crawford, E. David
    Rove, Kyle O.
    Brawer, Michael K.
    Smith, Matthew R.
    Petrylak, Daniel P.
    Steiner, Mitchell S.
    Morton, Ronald A.
    Frohlich, Mark W.
    JOURNAL OF UROLOGY, 2011, 185 (04): : E67 - E68
  • [47] ON THE VALIDITY OF SEVERAL COMMON ASSUMPTIONS IN THE DESIGN OF MACHINE-TOOL SPINDLE-BEARING SYSTEMS
    BRANDON, JA
    ALSHAREEF, KJH
    INTERNATIONAL JOURNAL OF MACHINE TOOLS & MANUFACTURE, 1991, 31 (02): : 235 - 248
  • [48] Determination of iron metabolism-related reference values in a healthy adult population
    Van den Bosch, G
    Van den Bossche, J
    Wagner, C
    De Schouwer, P
    Van de Vyvere, M
    Neels, H
    CLINICAL CHEMISTRY, 2001, 47 (08) : 1465 - 1467
  • [49] Integration of design systems for energy related applications
    Whittaker, T.J.T.
    Thornhill, D.
    Lu, S.
    Mitchell, D.
    Design Studies, 1995, 16 (04) : 415 - 428
  • [50] Assessment of the validity of current assumptions of the attenuation values defining coronary artery calcification on ultrafast CT when related to patient size
    Shalan, K
    Hartnell, GG
    Scholtz, E
    Kruskal, JB
    Clouse, ME
    RADIOLOGY, 1997, 205 : 1352 - 1352