Micro-WEDM of Ti-29Nb-13Ta-4.6Zr Alloy for Antibacterial Properties: Experimental Investigation and Optimization

被引:0
|
作者
Ali, Shahid [1 ]
Omarov, Salikh [1 ]
Utebayeva, Altynay [2 ]
Pham, Tri Thanh [2 ]
Talamona, Didier [1 ]
Perveen, Asma [1 ]
机构
[1] Nazarbayev Univ, Sch Engn & Digital Sci, Dept Mech & Aerosp Engn, Astana 010000, Kazakhstan
[2] Nazarbayev Univ, Sch Sci & Humanities, Dept Biol, Astana 010000, Kazakhstan
关键词
WEDM; beta titanium alloy; TNTZ; biocompatibility; surface treatment; biofilm formation; Taguchi optimization; antibacterial; NB-TA-ZR; MECHANICAL-PROPERTIES; TITANIUM-ALLOY; WEAR CHARACTERISTICS; CORROSION BEHAVIOR; TI-6AL-4V ALLOY; PERFORMANCE; TI; ROUGHNESS;
D O I
10.3390/met14060714
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Recent developments of orthopedic implant applications have discovered a variety of new metallic biomaterials known as beta-type titanium alloys. The mu-WEDM (micro-wire electro discharge machining) surface treatment technique, capable of improving the surface properties of orthopedic implants, was studied in a machining Ti-29Nb-13Ta-4.6Zr alloy. This study aimed to evaluate material removal rate (MRR), kerf width, average surface roughness, microhardness and antibacterial response at different machining parameters which are capacitance (1 nF, 10 nF and 100 nF) and gap voltage (80 V, 95 V and 110 V). The Taguchi method was used to optimize the mentioned output parameters, while ANOVA (analysis of variance) described the significance and contribution of capacitance and gap voltage. Grey relation analysis (GRA) was conducted to perform multiple output optimization. For antibacterial response, cultivations of B. subtilis, E. coli, P. aeruginosa and S. aureus bacteria on treated surfaces for 72 h were performed. As the results, optimal values of MRR, kerf width, crater area, average surface roughness and microhardness were equal to 0.0637 mm3/min, 93.0 mu m, 21.8 mu m2, 0.348 mu m and 442 HV, respectively. Meanwhile, mu-WEDM treatment improved antibacterial properties while the highest antibacterial response was achieved at the lowest average surface roughness resulting in least biofilm formation on treated surfaces.
引用
收藏
页数:20
相关论文
共 50 条
  • [31] Dental precision casting of Ti-29Nb-13Ta-4.6Zr using calcia mold
    Niinomi, M
    Akahori, T
    Takeuchi, T
    Katsura, S
    PRICM 5: THE FIFTH PACIFIC RIM INTERNATIONAL CONFERENCE ON ADVANCED MATERIALS AND PROCESSING, PTS 1-5, 2005, 475-479 : 2303 - 2307
  • [32] Electrochemical impedance spectroscopic characterisation of passive film formed over β Ti-29Nb-13Ta-4.6Zr alloy
    Raman, V.
    Nagarajan, S.
    Rajendran, N.
    ELECTROCHEMISTRY COMMUNICATIONS, 2006, 8 (08) : 1309 - 1314
  • [33] Effect of Oxygen on Phase Precipitation and Mechanical Functionality in Ti-29Nb-13Ta-4.6Zr
    Niinomi, Mitsuo
    Nakai, Masaaki
    Akahori, Toshikazu
    Tsutsumi, Harumi
    COST-AFFORDABLE TITANIUM III, 2010, 436 : 179 - 184
  • [34] Mechanical properties enhancement in Ti-29Nb-13Ta-4.6Zr alloy via heat treatment with no detrimental effect on its biocompatibility
    Najdahmadi, A.
    Zarei-Hanzaki, A.
    Farghadani, E.
    MATERIALS & DESIGN, 2014, 54 : 786 - 791
  • [35] Nanotube oxide coating on Ti-29Nb-13Ta-4.6Zr alloy prepared by self-organizing anodization
    Tsuchiya, Hiroaki
    Macak, Jan M.
    Ghicov, Andrei
    Tang, Yee Chin
    Fujimoto, Shinji
    Niinomi, Mitsuo
    Noda, Toshiharu
    Schmuki, Patrik
    ELECTROCHIMICA ACTA, 2006, 52 (01) : 94 - 101
  • [36] Tailoring the microstructure and mechanical properties of metastable Ti-29Nb-13Ta-4.6Zr alloy for self-expansible stent applications
    Plaine, Athos H.
    da Silva, Murillo R.
    Bolfarini, Claudemiro
    JOURNAL OF ALLOYS AND COMPOUNDS, 2019, 800 : 35 - 40
  • [37] Fatigue performance and cyto-toxicity of low rigidity titanium alloy, Ti-29Nb-13Ta-4.6Zr
    Niinomi, M
    BIOMATERIALS, 2003, 24 (16) : 2673 - 2683
  • [38] Fatigue characteristics of biomedical new β type titanium alloy, Ti-29Nb-13Ta-4.6Zr, relating with microstructure
    Niinomi, M
    Akahori, T
    Maekawa, T
    Kuroda, D
    Fukui, H
    Suzuki, A
    Hasegawa, J
    PRICM 4: FORTH PACIFIC RIM INTERNATIONAL CONFERENCE ON ADVANCED MATERIALS AND PROCESSING, VOLS I AND II, 2001, : 201 - 204
  • [39] Mechanical performance of newly developed β-type titanium alloy, Ti-29Nb-13Ta-4.6Zr, for biomedical applications
    Kuroda, D
    Niinomi, M
    Akahori, T
    Fukui, H
    Suzuki, A
    Hasegawa, J
    STRUCTURAL BIOMATERIALS FOR THE 21ST CENTURY, 2001, : 99 - 106
  • [40] Isotropic plasticity of β-type Ti-29Nb-13Ta-4.6Zr alloy single crystals for the development of single crystalline β-Ti implants
    Koji Hagihara
    Takayoshi Nakano
    Hideaki Maki
    Yukichi Umakoshi
    Mitsuo Niinomi
    Scientific Reports, 6