Study on the Hydration Heat Effect and Pipe Cooling System of a Mass Concrete Pile Cap

被引:2
|
作者
Wang, Bo [1 ,2 ]
Song, Yifan [2 ]
机构
[1] Dalian Univ Technol, Fac Infrastruct Engn, Dalian 116024, Peoples R China
[2] Changan Univ, Sch Highway, Inst Bridge Engn, Xian 710064, Peoples R China
关键词
mass concrete pile cap; hydration heat effect; adiabatic temperature rise; internal surface temperature difference; pipe cooling system; TEMPERATURE; STRENGTH;
D O I
10.3390/buildings14082413
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Under the action of cement hydration heat, the construction environment, thermal insulation measures, and pipe cooling systems, a mass concrete pile cap is subject to a complex internal temperature field, which makes it difficult to control its internal surface temperature difference (TISTD), the internal adiabatic temperature rise (TIATR), and the surface temperature (TST). In this study, a mass concrete pile cap of a very large bridge (the length, width, and height were 26.40 m, 20.90 m, and 5.00 m, respectively, and the central-pier pile cap was constructed with C40 concrete) was taken as the research object. The control factors affecting the temperature field of the pile cap were determined by comparing the field temperature measurements with the values calculated with finite element software simulation analysis. By using Midas Civil (2022 v1.2) and Midas FEA (NX 2022) finite element software, these factors (the concrete mold temperature, the concrete surface convection coefficient, the ambient temperature, the pipe cooling system parameters, etc.) were numerically analyzed, and their influence laws and degrees were determined.
引用
收藏
页数:19
相关论文
共 50 条
  • [41] Research on plugging effect of jacked prestressed concrete pipe pile
    Zhang Zhong-miao
    Liu Jun-wei
    Yu Feng
    Xie Zhi-zhuan
    ROCK AND SOIL MECHANICS, 2011, 32 (08) : 2274 - 2280
  • [42] EFFECT OF MATERIALS COMPONENT ON HYDRATION HEAT OF CONCRETE
    Wang, Peiming
    Pan, Wei
    Ma, Baoguo
    Wen, Xiaodong
    MICROSTRUCTURE RELATED DURABILITY OF CEMENTITIOUS COMPOSITES, VOLS 1 AND 2, 2008, 61 : 61 - +
  • [43] Experimental Study on Heat Extraction from Coal Pile by Heat Pipe
    Zhang, Yaping
    Quan, Xin
    Ning, Ning
    Wang, Jianguo
    2019 5TH INTERNATIONAL CONFERENCE ON ADVANCES IN ENERGY RESOURCES AND ENVIRONMENT ENGINEERING (ICAESEE 2019), 2020, 446
  • [44] Study of bearing performance of steel pipe settlement reducing pile with pile cap based on uniform design
    Huang Xiao-hui
    Gong Wei-ming
    Mu Bao-gang
    Huang Ting
    Xie Ri-cheng
    ROCK AND SOIL MECHANICS, 2014, 35 (11) : 3148 - 3156
  • [45] Experimental research on seismic performances of prestressed high-strength concrete pipe piles and pile-pile cap connections
    Wang, T.-C. (wangtiecheng@eyou.com), 1600, Chinese Society of Civil Engineering (35):
  • [46] Hydration Heat Control of Mass Concrete by Pipe Cooling Method and On-Site Monitoring-Based Influence Analysis of Temperature for a Steel Box Arch Bridge Construction
    Zhang, Tan
    Wang, Hua
    Luo, Yuejing
    Yuan, Ye
    Wang, Wensheng
    MATERIALS, 2023, 16 (07)
  • [47] Analysis of the cooling effect of a concrete thermal pile in permafrost regions
    Shang, Yunhu
    Niu, Fujun
    Lin, Zhanju
    Sun, Tian
    APPLIED THERMAL ENGINEERING, 2020, 173
  • [48] Study of pipe group effects efficiency of belled wedge pile with low cap
    Kong Gang-qiang
    Gu Hong-wei
    Zhou Li-duo
    Peng Huai-feng
    ROCK AND SOIL MECHANICS, 2016, 37 (37) : 461 - 468
  • [49] Study on heat transfer of a rotating heat pipe cooling system in dry abrasive-milling
    Chen, Jiajia
    Fu, Yucan
    Gu, Zhibin
    Shen, Houfa
    He, Qingshan
    APPLIED THERMAL ENGINEERING, 2017, 115 : 736 - 743
  • [50] Experimental Study of Heat Pipe Exchanger for High Power LED Cooling System
    Gou Yun-Jun
    Zhong Xiao-hui
    MECHATRONICS AND INTELLIGENT MATERIALS II, PTS 1-6, 2012, 490-495 : 2278 - +