Robustness analysis of dynamic trajectory radiotherapy and volumetric modulated arc therapy plans for head and neck cancer

被引:1
|
作者
Loebner, Hannes A. [1 ,2 ,3 ]
Bertholet, Jenny [1 ,2 ,3 ]
Mackeprang, Paul-Henry [1 ,2 ,3 ]
Volken, Werner [1 ,2 ,3 ]
Elicin, Olgun [1 ,2 ,3 ]
Mueller, Silvan [1 ,2 ,3 ]
Guyer, Gian [1 ,2 ,3 ]
Aebersold, Daniel M. [1 ,2 ,3 ]
Stampanoni, Marco F. M. [2 ,4 ,5 ]
Fix, Michael K. [1 ,3 ]
Manser, Peter [1 ,2 ,3 ]
机构
[1] Bern Univ Hosp, Div Med Radiat Phys, Inselspital, Inselspital, Freiburgstrasse 18, CH-3010 Bern, Switzerland
[2] Bern Univ Hosp, Dept Radiat Oncol, Inselspital, Freiburgstrasse 18, Bern, Switzerland
[3] Univ Bern, Bern, Switzerland
[4] Swiss Fed Inst Technol, Inst Biomed Engn, Villigen, Switzerland
[5] PSI, Villigen, Switzerland
关键词
Head and neck cancer; Dynamic trajectory radiotherapy; VMAT; Robustness; Setup uncertainty; Machine uncertainty; SET-UP ERRORS; PLANNING MARGINS; UNCERTAINTIES; QUALITY; IMRT; VMAT; PERFORMANCE; SYSTEMS; ORGANS; RISK;
D O I
10.1016/j.phro.2024.100586
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background and purpose: Dynamic trajectory radiotherapy (DTRT) has been shown to improve healthy tissue sparing compared to volumetric arc therapy (VMAT). This study aimed to assess and compare the robustness of DTRT and VMAT treatment-plans for head and neck (H &N) cancer to patient-setup (PS) and machine-positioning uncertainties. Materials and methods: The robustness of DTRT and VMAT plans previously created for 46 H &N cases, prescribed 50 - 70 Gy to 95 % of the planning-target-volume, was assessed. For this purpose, dose distributions were recalculated using Monte Carlo, including uncertainties in PS (translation and rotation) and machine-positioning (gantry-, table-, collimator-rotation and multi-leaf collimator (MLC)). Plan robustness was evaluated by the uncertainties ' impact on normal tissue complication probabilities (NTCP) for xerostomia and dysphagia and on dose-volume endpoints. Differences between DTRT and VMAT plan robustness were compared using Wilcoxon matched-pair signed-rank test ( alpha = 5 %). Results: Average NTCP for moderate-to-severe xerostomia and grade >= II dysphagia was lower for DTRT than VMAT in the nominal scenario (0.5 %, p = 0.01; 2.1 %, p < 0.01) and for all investigated uncertainties, except MLC positioning, where the difference was not significant. Average differences compared to the nominal scenario were <= 3.5 Gy for rotational PS (<= 3 degrees ) and machine-positioning (<= 2 degrees ) uncertainties, <7 Gy for translational PS uncertainties (<= 5 mm) and < 20 Gy for MLC-positioning uncertainties (<= 5 mm). Conclusions: DTRT and VMAT plan robustness to the investigated uncertainties depended on uncertainty direction and location of the structure-of-interest to the target. NTCP remained on average lower for DTRT than VMAT even when considering uncertainties.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Adaptive Radiotherapy in Head and Neck Cancer Using Volumetric Modulated Arc Therapy
    Buciuman, Nikolett
    Marcu, Loredana G.
    [J]. JOURNAL OF PERSONALIZED MEDICINE, 2022, 12 (05):
  • [2] Volumetric Modulated Arc Therapy for Head & Neck Cancer
    Afghan, M. K. N.
    Cao, D.
    Mehta, V.
    Shepard, D.
    [J]. MEDICAL PHYSICS, 2008, 35 (06) : 2901 - +
  • [3] Robustness quantification methods comparison in volumetric modulated arc therapy to treat head and neck cancer
    Liu, Wei
    Patel, Samir H.
    Shen, Jiajian
    Hu, Yanle
    Harrington, Daniel P.
    Ding, Xiaoning
    Halyard, Michele Y.
    Schild, Steven E.
    Wong, William W.
    Ezzell, Gary A.
    Bues, Martin
    [J]. PRACTICAL RADIATION ONCOLOGY, 2016, 6 (06) : E269 - E275
  • [4] Single Arc Volumetric Modulated Arc Therapy of head and neck cancer
    Bertelsen, Anders
    Hansen, Christian R.
    Johansen, Jorgen
    Brink, Carsten
    [J]. RADIOTHERAPY AND ONCOLOGY, 2010, 95 (02) : 142 - 148
  • [5] Is there a dosimetric advantage of volumetric modulated arc therapy over intensity modulated radiotherapy in head and neck cancer?
    Buciuman, Nikolett
    Marcu, Loredana G.
    [J]. EUROPEAN ARCHIVES OF OTO-RHINO-LARYNGOLOGY, 2022, 279 (11) : 5311 - 5321
  • [6] Is there a dosimetric advantage of volumetric modulated arc therapy over intensity modulated radiotherapy in head and neck cancer?
    Nikolett Buciuman
    Loredana G. Marcu
    [J]. European Archives of Oto-Rhino-Laryngology, 2022, 279 : 5311 - 5321
  • [7] Plan Robustness Study of Volumetric Modulated Arc Therapy Versus Intensity Modulated Radiation Therapy for Head and Neck Cancer
    Liu, W.
    Patel, S. H.
    Shen, J.
    Stoker, J.
    Ding, X.
    Hu, Y.
    Wong, W. W.
    Halyard, M. Y.
    Ezzell, G. A.
    Schild, S. E.
    Bues, M.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2015, 93 (03): : E567 - E568
  • [8] Correlation Study of Volumetric Modulated Arc Therapy Plan Robustness With Local Failure for Head and Neck Cancer
    Liu, W.
    Patel, S. H.
    Harrington, D.
    Stoker, J.
    Ding, X.
    Shen, J.
    Wong, W. W.
    Halyard, M. Y.
    Schild, S. E.
    Ezzell, G. A.
    Bues, M.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2015, 93 (03): : E309 - E310
  • [9] Increasing the number of arcs improves head and neck volumetric modulated arc therapy plans
    Tol, Jim P.
    Dahele, Max
    Slotman, Ben J.
    Verbakel, Wilko F. A. R.
    [J]. ACTA ONCOLOGICA, 2015, 54 (02) : 283 - U157
  • [10] Volumetric Modulated Arc Therapy Optimization Strategy for a Head and Neck Cancer
    Singh, N.
    Ahamed, S.
    [J]. MEDICAL PHYSICS, 2018, 45 (06) : E290 - E290