Intelligent prediction of 110kV insulator lightning flashover criteria based on random forest

被引:3
|
作者
He, Shaomin [1 ]
Han, Yongxia [1 ]
Zhao, Zicai [1 ]
Liu, Gang [2 ]
Qu, Lu [2 ]
Huang, Zhidu [3 ]
Zhang, Yaqi [4 ]
Liu, Boxuan [1 ]
Wu, Zhongyang [1 ]
Li, Licheng [1 ]
机构
[1] South China Univ Technol, Sch Elect Power, Guangzhou 510641, Peoples R China
[2] China Southern Power Grid, Elect Power Res Inst, Guangzhou 510663, Peoples R China
[3] Elect Power Res Inst Guangxi Power Grid Co Ltd, Nanning 530023, Peoples R China
[4] Guangdong Polytech Normal Univ, Coll Automat, Guangzhou 510450, Peoples R China
关键词
Flashover criteria; Lightning impulse; Test database; Prediction; Random forest;
D O I
10.1016/j.epsr.2024.110423
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The lightning flashover criteria of insulators vary significantly under different conditions, and it is impractical to exhaustively enumerate all the criteria through extensive tests. Therefore, this paper aims to explore the intelligent prediction of lightning flashover criteria for 110 kV insulators using a data-driven approach. Initially, a test database comprising 4,978 high- and low-altitude test data of 110 kV insulator lightning impulse flashover is established. Subsequently, relevant characteristic values are extracted from the database as inputs for the prediction model. Various machine learning algorithms, such as the BPNN, SVM and RF algorithms, are employed to construct prediction models for the U50% and volt-time characteristics of 110 kV insulators under lightning impulses. The results demonstrate that the RF algorithm yields an average absolute percentage error of merely 1.17 % for the U50% prediction model. Additionally, the RF and BP algorithms achieve the highest prediction accuracies of 10.7 % and 6.5 %, respectively, for the volt-time characteristics at high- and low-altitude. This validates the feasibility of substituting many traditional tests with more accurate flashover criteria predicted through a data-driven approach. This paper provides a novel concept for predicting the lightning impulse flashover criteria of insulators under different working conditions. Reducing the need for repetitive tests is expected to acquire the high-precision intelligent prediction of insulator lightning impulse flashover criteria.
引用
收藏
页数:11
相关论文
共 50 条
  • [21] Lightning Impulse Arc Development Process and Flashover Characteristics of 110 kV SIR Insulators Under Heavy Rainstorms
    Dong B.
    Song J.
    Li T.
    Li J.
    Jiang X.
    Gaodianya Jishu/High Voltage Engineering, 2023, 49 (02): : 525 - 535
  • [22] Analysis and Countermeasure on Abnormal Operation of One 110kV Intelligent Substation Merging Unit
    Ji Jianfei
    Wang Lihui
    Yuan Yubo
    Gao Lei
    PROCEEDINGS 2013 INTERNATIONAL CONFERENCE ON MECHATRONIC SCIENCES, ELECTRIC ENGINEERING AND COMPUTER (MEC), 2013, : 3509 - 3515
  • [23] Hot-line assembly strategy for connection fittings in 110kV intelligent substation
    Tang, Mingdong
    Gu, Youlin
    Wang, Shigang
    Liang, Qinghua
    Wang, Xiaoxi
    INDUSTRIAL ROBOT-THE INTERNATIONAL JOURNAL OF ROBOTICS RESEARCH AND APPLICATION, 2018, 45 (04): : 539 - 548
  • [24] Influence of the Electric Field on TSC Characteristics of 110kV Silicone Rubber Insulator Sheds in Service
    Zhang, Hui
    Tu, Youping
    Lu, Yi
    Chen, Jingjing
    Chen, Conghui
    Xie, Lifang
    CONFERENCE RECORD OF THE 2012 IEEE INTERNATIONAL SYMPOSIUM ON ELECTRICAL INSULATION (ISEI), 2012, : 469 - 472
  • [25] Prediction of Flashover Voltage on 11 kV Composite Insulator Using Kernel Support Vector Machine
    Kumar, K.
    Vigneshwaran, B.
    Priya, K. Vishnu
    Vadivoo, T. Sreevidya Chidambara
    SOFT COMPUTING FOR PROBLEM SOLVING, SOCPROS 2018, VOL 2, 2020, 1057 : 43 - 54
  • [26] Study on the Influencing Factors of Insulator on the Back-Flashover Lightning Withstand Performance of ±800 kV UHVDC Transmission Lines
    Jiang, Wenbo
    Tang, Chunlin
    Zhou, Bo
    MATHEMATICAL PROBLEMS IN ENGINEERING, 2020, 2020
  • [27] Effect of both salt and non-soluble deposit densities on flashover voltage of 110 kV composite insulator
    Key Laboratory of High Voltage Engineering and Electrical New Technology, Chongqing University, Chongqing 400044, China
    Zhongguo Dianji Gongcheng Xuebao, 2006, 9 (150-154):
  • [28] Lightning performance and its prevention for quadruple-circuit transmission line with 220kV/110kV voltage in a tower
    Chunhua, L. (sjyouxiang@sohu.com), 2013, Universitas Ahmad Dahlan, Jalan Kapas 9, Semaki, Umbul Harjo,, Yogiakarta, 55165, Indonesia (11):
  • [29] Design and Implementation of Visualizing the Intelligent Dispatching and Maintenance Arrangement System for 110kV Power Grid
    Xu, Zhen Chao
    Yao, Jian Gang
    Wei, Yi Long
    ENERGY AND POWER TECHNOLOGY, PTS 1 AND 2, 2013, 805-806 : 1194 - 1197
  • [30] Flashover Performance Test with Lightning Impulse and Simulation Analysis of Different Insulators in a 110 kV Double-Circuit Transmission Tower
    Zhang, Yaqi
    Li, Licheng
    Han, Yongxia
    Ruan, Yaoxuan
    Yang, Jie
    Cai, Hansheng
    Liu, Gang
    Zhang, Yi
    Jia, Lei
    Ma, Yutang
    ENERGIES, 2018, 11 (03):