Intelligent prediction of 110kV insulator lightning flashover criteria based on random forest

被引:3
|
作者
He, Shaomin [1 ]
Han, Yongxia [1 ]
Zhao, Zicai [1 ]
Liu, Gang [2 ]
Qu, Lu [2 ]
Huang, Zhidu [3 ]
Zhang, Yaqi [4 ]
Liu, Boxuan [1 ]
Wu, Zhongyang [1 ]
Li, Licheng [1 ]
机构
[1] South China Univ Technol, Sch Elect Power, Guangzhou 510641, Peoples R China
[2] China Southern Power Grid, Elect Power Res Inst, Guangzhou 510663, Peoples R China
[3] Elect Power Res Inst Guangxi Power Grid Co Ltd, Nanning 530023, Peoples R China
[4] Guangdong Polytech Normal Univ, Coll Automat, Guangzhou 510450, Peoples R China
关键词
Flashover criteria; Lightning impulse; Test database; Prediction; Random forest;
D O I
10.1016/j.epsr.2024.110423
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The lightning flashover criteria of insulators vary significantly under different conditions, and it is impractical to exhaustively enumerate all the criteria through extensive tests. Therefore, this paper aims to explore the intelligent prediction of lightning flashover criteria for 110 kV insulators using a data-driven approach. Initially, a test database comprising 4,978 high- and low-altitude test data of 110 kV insulator lightning impulse flashover is established. Subsequently, relevant characteristic values are extracted from the database as inputs for the prediction model. Various machine learning algorithms, such as the BPNN, SVM and RF algorithms, are employed to construct prediction models for the U50% and volt-time characteristics of 110 kV insulators under lightning impulses. The results demonstrate that the RF algorithm yields an average absolute percentage error of merely 1.17 % for the U50% prediction model. Additionally, the RF and BP algorithms achieve the highest prediction accuracies of 10.7 % and 6.5 %, respectively, for the volt-time characteristics at high- and low-altitude. This validates the feasibility of substituting many traditional tests with more accurate flashover criteria predicted through a data-driven approach. This paper provides a novel concept for predicting the lightning impulse flashover criteria of insulators under different working conditions. Reducing the need for repetitive tests is expected to acquire the high-precision intelligent prediction of insulator lightning impulse flashover criteria.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Study on the flashover characteristics of bird droppings along 110kV composite insulator
    Wang, Huaqian
    Wang, Shenghui
    Deng, Changyu
    Yang, Guanghua
    Lv, Fangcheng
    2018 INTERNATIONAL CONFERENCE ON POWER SYSTEM TECHNOLOGY (POWERCON), 2018, : 2929 - 2933
  • [2] Numerical Simulation of the Lightning Impulse Flashover of 11 kV Polymeric Insulator
    Haque, Noorul M.
    Sunitha, K.
    2022 IEEE 6TH INTERNATIONAL CONFERENCE ON CONDITION ASSESSMENT TECHNIQUES IN ELECTRICAL SYSTEMS, CATCON, 2022, : 279 - 282
  • [3] Study on Flashover Characteristic and Critical Flashover Current of icing and polluted 110kV Composite Insulators
    Bi, Maoqiang
    Yang, Zhangang
    Jiang, Tianyan
    Chen, Xi
    Wang, You
    2018 IEEE INTERNATIONAL CONFERENCE ON HIGH VOLTAGE ENGINEERING AND APPLICATION (ICHVE), 2018,
  • [4] Analysis and Verification of Strength of 110kV Porcelain Post Insulator
    Jin, Songan
    Mo, Wenxiong
    Wei, Jingrong
    Lu, Guojun
    Li, Xiyu
    Wang, Yong
    Liu, Chaofeng
    Min, Chao
    Dang, Zhenping
    Wang, Le
    2017 4TH INTERNATIONAL CONFERENCE ON ELECTRIC POWER EQUIPMENT-SWITCHING TECHNOLOGY (ICEPE-ST), 2017, : 1010 - 1014
  • [5] Lightning Overvoltage Study of 110kV Neutral Resistance Grounding System
    Wang, Shenjie
    Lv, Yanping
    Liu, Fei
    INTERNATIONAL CONFERENCE ON ELECTRONIC AND ELECTRICAL ENGINEERING (CEEE 2014), 2014, : 341 - 346
  • [6] Analysis of the Pollution Accumulation and Flashover Characteristics of Field aged 110kV Composite Insulators
    Zhang, Zhijin
    Huang, Haizhou
    Jiang, Xingliang
    Chen, Mingying
    Hu, Jianlin
    2011 ELECTRICAL INSULATION CONFERENCE (EIC), 2011, : 120 - 124
  • [8] Lightning Impulse Pollution Flashover Characteristics and Model of 10 kV Composite Arrester Combined Insulator
    Xinhan, Qiao
    Zhijin, Zhang
    Zhenglong, Jiang
    Xingliang, Jiang
    Guohui, Pang
    Diangong Jishu Xuebao/Transactions of China Electrotechnical Society, 2024, 39 (21): : 6932 - 6940
  • [9] Switching impulse flashover performance of 110 kV composite insulator covered-with ice
    Jiang, Xing-Liang
    Sheng, Dao-Wei
    Yuan, Ji-He
    Gaodianya Jishu/High Voltage Engineering, 2009, 35 (04): : 772 - 776
  • [10] Analysis and Discussion on Lightning Disturbance on 110kV Transmission Line in Mountainous Area
    Jing Liangbing
    Li Jinglu
    Xu Genyang
    Yan Xiping
    2008 PROCEEDINGS OF THE 43RD INTERNATIONAL UNIVERSITIES POWER ENGINEERING CONFERENCE, VOLS 1-3, 2008, : 1013 - +