Construction of a Near-Infrared Fluorescent Probe for Dynamic Monitoring and Early Diagnosis of Heart Failure

被引:2
|
作者
Su, Lina [1 ,2 ]
Wang, Junda [3 ]
Liu, Bowei [1 ]
Liu, Hui [3 ]
Chen, Qixin [2 ]
Liu, Jiang [1 ]
Li, Shuolei [4 ]
Yuan, Lan [5 ]
An, Lihua [5 ]
Lin, Hang [2 ]
Feng, Lina [1 ]
Zheng, Jingang [1 ]
Ren, Jingyi [1 ]
Liang, Lei [3 ]
Li, Sufang [2 ]
机构
[1] China Japan Friendship Hosp, Heart Failure Ctr, Dept Cardiol, Beijing 100029, Peoples R China
[2] Peking Univ, Ctr Cardiovasc Translat Res, Beijing Key Lab Early Predict & Intervent Acute M, Peoples Hosp,Dept Cardiol, Beijing 100044, Peoples R China
[3] Peking Univ, Sch Pharmaceut Sci, Dept Med Chem, Beijing 100191, Peoples R China
[4] Peking Univ Peoples Hosp, Lab Anim Unit, Beijing 100044, Peoples R China
[5] Peking Univ, Med & Hlth Analyt Ctr, Beijing 100191, Peoples R China
来源
ACS SENSORS | 2024年 / 9卷 / 06期
基金
中国国家自然科学基金; 国家重点研发计划;
关键词
NIR fluorescence probe; early diagnosis; heartfailure; cells viscosity; cardiac hypertrophy; pyridazinone; RATIONAL DESIGN; FAR-RED; HYDROGEN-PEROXIDE; VISCOSITY; DYES; INFLAMMATION; DERIVATIVES; MODELS; CELLS; IONS;
D O I
10.1021/acssensors.4c00258
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Cardiac hypertrophy characterized by abnormal cardiomyocyte viscosity is a typical sign of heart failure (HF) with vital importance for early diagnosis. However, current biochemical and imaging diagnostic methods are unable to detect this subclinical manifestation. In this work, we developed a series of NIR-I fluorescence probes for detecting myocardial viscosity based on the pyridazinone scaffold. The probes showed weak fluorescence due to free intramolecular rotation under low-viscosity conditions, while they displayed strong fluorescence with limited intramolecular rotation in response to a high-viscosity environment. Among them, CarVis2 exhibited higher stability and photobleaching resistance than commercial dyes. Its specific response to viscosity was not influenced by the pH and biological species. Furthermore, CarVis2 showed rapid and accurate responses to the viscosity of isoproterenol (ISO)-treated H9C2 cardiomyocytes with good biocompatibility. More importantly, CarVis2 demonstrated excellent sensitivity in monitoring myocardial viscosity variation in HF mice in vivo, potentially enabling earlier noninvasive identification of myocardial abnormalities compared to traditional clinical imaging and biomarkers. These findings revealed that CarVis2 can serve as a powerful tool to monitor myocardial viscosity, providing the potential to advance insights into a pathophysiological mechanism and offering a new reference strategy for early visual diagnosis of HF.
引用
收藏
页码:3075 / 3084
页数:10
相关论文
共 50 条
  • [41] Synthesis of a new deoxyglucose derivative modified near-infrared fluorescent probe for tumor diagnosis
    Sun, Chunlong
    Du, Wen
    Wang, Baoqin
    Yao, Zhigang
    Liu, Junhua
    Wang, Jun
    Xie, Wenjun
    Wu, Tao
    Fan, Yanhui
    Yang, Hongjun
    BIOCHEMICAL AND BIOPHYSICAL RESEARCH COMMUNICATIONS, 2017, 488 (02) : 340 - 347
  • [42] Fabrication of a Redox-Reversible Near-Infrared Fluorogenic Probe for Ferroptosis Process Monitoring and the Early Diagnosis of Diabetes
    He, Lingchao
    Wei, Xiao
    Zhang, Wei
    Xu, Ningge
    Wu, Jinsheng
    Yu, Fabiao
    Liu, Heng
    ANALYTICAL CHEMISTRY, 2025, 97 (04) : 2411 - 2417
  • [43] The construction of a near-infrared fluorescent probe with dual advantages for imaging carbon monoxide in cells and in vivo
    Tian, Yang
    Jiang, Wen-Li
    Wang, Wen-Xin
    Peng, Jie
    Li, Xue-Meng
    Li, Yongfei
    Li, Chun-Yan
    ANALYST, 2021, 146 (01) : 118 - 123
  • [44] Construction of a dual "off-on" near-infrared fluorescent probe for bioimaging of HClO in rheumatoid arthritis
    Wu, Jisong
    Xia, Wenchao
    Lu, Yuan
    Yao, Shankun
    Chen, Yuncong
    Guo, Zijian
    TALANTA, 2024, 280
  • [45] Imaging Tumorous Methylglyoxal by an Activatable Near-Infrared Fluorescent Probe for Monitoring Glyoxalase 1 Activity
    Ding, Chunyong
    Wang, Fengyang
    Dang, Yijing
    Xu, Zhiai
    Li, Lingling
    Lai, Yi
    Yu, Haijun
    Luo, Yi
    Huang, Ruimin
    Zhang, Ao
    Zhang, Wen
    ANALYTICAL CHEMISTRY, 2019, 91 (24) : 15577 - 15584
  • [46] Monitoring the Fluctuation of Hydrogen Peroxide in Diabetes and Its Complications with a Novel Near-Infrared Fluorescent Probe
    Wang, Wen-Xin
    Jiang, Wen-Li
    Mao, Guo-Jiang
    Tan, Min
    Fei, Junjie
    Li, Yongfei
    Li, Chun-Yan
    ANALYTICAL CHEMISTRY, 2021, 93 (06) : 3301 - 3307
  • [47] An activatable near-infrared fluorescent probe targeting CKIP-1 for monitoring osteoporosis in vivo
    Yang, Xi
    Ding, Yi
    Wang, Xiaolu
    Dai, Hongmiao
    Xu, Haifeng
    Wu, Bo
    He, Xiaoyang
    Zhang, Yuxuan
    Li, Xin
    Jin, Yiguang
    Cui, Chun-Ping
    Peng, Jiang
    Cui, Yu
    Zhang, Lingqiang
    SENSORS AND ACTUATORS B-CHEMICAL, 2021, 346
  • [48] Selective Near-Infrared Fluorescent Probe for Monitoring Thiophenol in Real Water Samples and Living Cells
    Zhang, Chunyan
    Hao, Yuanqiang
    ANALYTICAL LETTERS, 2021, 54 (08) : 1366 - 1376
  • [49] A novel hydrosoluble near-infrared fluorescent probe for specifically monitoring tyrosinase and application in a mouse model
    Zhang, Jiahang
    Li, Zhao
    Tian, Xinwei
    Ding, Ning
    CHEMICAL COMMUNICATIONS, 2019, 55 (64) : 9463 - 9466
  • [50] Monitoring the level of hydrogen sulfide in arthritis and its treatment with a novel near-infrared fluorescent probe
    Chao, Jing-Jing
    Hu, Ling
    Mi, Jing-Fang
    Mao, Guo-Jiang
    Xu, Fen
    Hu, Liufang
    Ouyang, Juan
    Li, Chun-Yan
    ANALYTICA CHIMICA ACTA, 2025, 1351