Automatic removal of large blood vasculature for objective assessment of brain tumors using quantitative dynamic contrast-enhanced magnetic resonance imaging

被引:2
|
作者
Kesari, Anshika [1 ]
Yadav, Virendra Kumar [1 ]
Gupta, Rakesh Kumar [2 ]
Singh, Anup [1 ,3 ,4 ]
机构
[1] Indian Inst Technol, Ctr Biomed Engn, New Delhi 110016, Delhi, India
[2] Fortis Mem Res Inst, Dept Radiol, Gurugram, India
[3] All India Inst Med Sci, Dept Biomed Engn, New Delhi, India
[4] Indian Inst Technol, Yardi Sch Artificial Intelligence, New Delhi, Delhi, India
关键词
blood vasculature; brain tumor; DCE-MRI; k-means clustering; quantitative maps; segmentation; tumor grading; CENTRAL-NERVOUS-SYSTEM; DIAGNOSTIC-ACCURACY; HIGH-GRADE; K-MEANS; MRI; DCE; SEGMENTATION; GLIOMA; CLASSIFICATION; PERMEABILITY;
D O I
10.1002/nbm.5218
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The presence of a normal large blood vessel (LBV) in a tumor region can impact the evaluation of quantitative dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) parameters and tumor classification. Hence, there is a need for automatic removal of LBVs from brain tissues including intratumoral regions for achieving an objective assessment of tumors. This retrospective study included 103 histopathologically confirmed brain tumor patients who underwent MRI, including DCE-MRI data acquisition. Quantitative DCE-MRI analysis was performed for computing various parameters such as wash-out slope (Slope-2), relative cerebral blood volume (rCBV), relative cerebral blood flow (rCBF), blood plasma volume fraction (Vp), and volume transfer constant (K-trans). An approach based on data-clustering algorithm, morphological operations, and quantitative DCE-MRI maps was proposed for the segmentation of normal LBVs in brain tissues, including the tumor region. Here, three widely used data-clustering algorithms were evaluated on two types of quantitative maps: (a) Slope-2, and (b) a new proposed combination of rCBV and Slope-2 maps. Fluid-attenuated inversion recovery-MRI hyperintense lesions were also automatically segmented using deep learning-based architecture. The accuracy of LBV segmentation was qualitatively assessed blindly by two experienced observers, and Likert scoring was also obtained from each individual and compared using Cohen's Kappa test, and multiple statistical features from quantitative DCE-MRI parameters were obtained in the segmented tumor. t-test and receiver operating characteristic (ROC) curve analysis were performed for comparing the effect of removal of LBVs on parameters as well as on tumor grading. k-means clustering exhibited better accuracy and computational efficiency. Tumors, in particular high-grade gliomas (HGGs), showed a high contrast compared with normal tissues (relative % difference = 18.5%) on quantitative maps after the removal of LBVs. Statistical features (95(th) percentile values) of all parameters in the tumor region showed a statistically significant difference (p < 0.05) between with and without LBV maps. Similar results were obtained for the ROC curve analysis for differentiation between low-grade gliomas and HGGs. Moreover, after the removal of LBVs, the rCBV, rCBF, and Vp maps show better visualization of tumor regions.
引用
收藏
页数:14
相关论文
共 50 条
  • [41] Functional tumor imaging with dynamic contrast-enhanced magnetic resonance imaging
    Choyke, PL
    Dwyer, AJ
    Knopp, MV
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2003, 17 (05) : 509 - 520
  • [42] Contrast-enhanced dynamic magnetic resonance imaging of the rat kidney
    Fransen, R
    Muller, HJ
    Boer, WH
    Nicolay, K
    Koomans, HA
    JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 1996, 7 (03): : 424 - 430
  • [43] Dynamic Contrast-enhanced Magnetic Resonance Imaging: Applications in Oncology
    Teo, Q. Q.
    Thng, C. H.
    Koh, T. S.
    Ng, Q. S. p
    CLINICAL ONCOLOGY, 2014, 26 (10) : E9 - E20
  • [44] Vascularity and Dynamic Contrast-Enhanced Breast Magnetic Resonance Imaging
    Frankhouser, David E.
    Dietze, Eric
    Mahabal, Ashish
    Seewaldt, Victoria L.
    FRONTIERS IN RADIOLOGY, 2021, 1
  • [45] Assessment of Prostate Cancer Aggressiveness Using Dynamic Contrast-enhanced Magnetic Resonance Imaging at 3 T
    Vos, Eline K.
    Litjens, Geert J. S.
    Kobus, Thiele
    Hambrock, Thomas
    Hulsbergen-van de Kaa, Christina A.
    Barentsz, Jelle O.
    Huisman, Henkjan J.
    Scheenen, Tom W. J.
    EUROPEAN UROLOGY, 2013, 64 (03) : 448 - 455
  • [46] Dynamic contrast-enhanced magnetic resonance imaging of the sarcopenic muscle
    Nicolato E.
    Farace P.
    Asperio R.M.
    Marzola P.
    Lunati E.
    Sbarbati A.
    Osculati F.
    BMC Medical Imaging, 2 (1)
  • [47] Information Criteria for Dynamic Contrast-Enhanced Magnetic Resonance Imaging
    Shinohara, Russell T.
    Crainiceanu, Ciprian S.
    Caffo, Brian S.
    Reich, Daniel S.
    2013 3RD INTERNATIONAL WORKSHOP ON PATTERN RECOGNITION IN NEUROIMAGING (PRNI 2013), 2013, : 37 - 41
  • [48] ASSESSMENT OF TUMOR RADIORESPONSIVENESS AND METASTATIC POTENTIAL BY DYNAMIC CONTRAST-ENHANCED MAGNETIC RESONANCE IMAGING
    Ovrebo, Kirsti Marie
    Gulliksrud, Kristine
    Mathiesen, Berit
    Rofstad, Einar K.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2011, 81 (01): : 255 - 261
  • [49] Measurement of tumor blood flow using dynamic contrast-enhanced magnetic resonance imaging and deconvolution analysis: A preliminary study in musculoskeletal tumors
    Sugawara, Yoshifumi
    Murase, Kenya
    Kikuchi, Keiichi
    Sakayama, Kenshi
    Miyazaki, Tatsuhiko
    Kajihara, Makoto
    Miki, Hitoshi
    Mochizuki, Teruhito
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2006, 30 (06) : 983 - 990
  • [50] Dynamic Contrast-Enhanced Sonography and Dynamic Contrast-Enhanced Magnetic Resonance Imaging for Preoperative Diagnosis of Infected Nonunions
    Fischer, Christian
    Preuss, Eva-Maria
    Tanner, Michael
    Bruckner, Thomas
    Krix, Martin
    Amarteifio, Erick
    Miska, Matthias
    Moghaddam-Alvandi, Arash
    Schmidmaier, Gerhard
    Weber, Marc-Andre
    JOURNAL OF ULTRASOUND IN MEDICINE, 2016, 35 (05) : 933 - 942