Quantifying neutron scintillator screens with X-ray computed tomography

被引:0
|
作者
Chuirazzi, William [1 ]
Cool, Steven [2 ]
Craft, Aaron [1 ]
机构
[1] Idaho Natl Lab, Postirradiat Examinat Dept, Mat & Fuels Complex, Idaho Falls, ID 83415 USA
[2] DMI Reading Imaging, Reading, MA 01867 USA
关键词
X-ray computed tomography; Neutron scintillator screen; Nondestructive examination; Scintillator screen characterization; DISTANCE TRANSFORMS; TECHNOLOGY; CONCRETE;
D O I
10.1016/j.nima.2024.169248
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
As nondestructive imaging techniques become more commonplace, imaging systems must be improved and optimized to meet the growing demand. One key aspect of neutron imaging systems is the scintillator, which determines the time necessary to acquire an image and can also limit the spatial resolution achievable by a system. In this work, X-ray computed tomography was coupled with image processing to measure parameters of a boron-based neutron scintillator screen. The screen's surface and subsurface were examined for defects and a thickness measurement as a function of position was also successfully implemented. Higher resolution scans of a sub-volume of the scintillator coating enabled visualization of the packing of the converter and phosphor powders while also revealing microscopic porosity within the scintillator material. The converter-to-phosphor ratio was quantified with the examined area showing a ZnS:Ag phosphor volume of approximately 60.70% of the entire scintillator volume, while Na10B5O8 converter accounted for approximately 38.76% of the volume.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] The use of x-ray computed tomography in quantifying air voids in asphalt compacted specimens
    Saleh, H
    Masad, E
    [J]. NONDESTRUCTIVE CHARACTERIZATION OF MATERIALS XI, 2003, : 269 - 269
  • [22] Quantitative cone beam X-ray luminescence tomography/X-ray computed tomography imaging
    Chen, Dongmei
    Zhu, Shouping
    Chen, Xueli
    Chao, Tiantian
    Cao, Xu
    Zhao, Fengjun
    Huang, Liyu
    Liang, Jimin
    [J]. APPLIED PHYSICS LETTERS, 2014, 105 (19)
  • [23] Terahertz, X-ray and neutron computed tomography of an Eighteenth Dynasty Egyptian sealed pottery
    E. Abraham
    M. Bessou
    A. Ziéglé
    M.-C. Hervé
    L. Szentmiklósi
    Z. S. Kasztovszky
    Z. Kis
    M. Menu
    [J]. Applied Physics A, 2014, 117 : 963 - 972
  • [24] Terahertz, X-ray and neutron computed tomography of an Eighteenth Dynasty Egyptian sealed pottery
    Abraham, E.
    Bessou, M.
    Ziegle, A.
    Herve, M-C.
    Szentmiklosi, L.
    Kasztovszky, Z. S.
    Kis, Z.
    Menu, M.
    [J]. APPLIED PHYSICS A-MATERIALS SCIENCE & PROCESSING, 2014, 117 (03): : 963 - 972
  • [25] X-ray luminescence computed tomography using a focused x-ray beam
    Zhang, Wei
    Lun, Michael C.
    Nguyen, Alex Anh-Tu
    Li, Changqing
    [J]. JOURNAL OF BIOMEDICAL OPTICS, 2017, 22 (11)
  • [26] X-ray Digital Radiography and Computed Tomography
    Morigi, Maria Pia
    Albertin, Fauzia
    [J]. JOURNAL OF IMAGING, 2022, 8 (05)
  • [27] STATISTICAL ASPECTS OF COMPUTED X-RAY TOMOGRAPHY
    CHESLER, DA
    PELC, NJ
    RIEDERER, SJ
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1977, 22 (01): : 130 - 131
  • [28] X-ray computed tomography of ultralightweight metals
    Winter, JM
    Green, RE
    Waters, AM
    Green, WH
    [J]. RESEARCH IN NONDESTRUCTIVE EVALUATION, 1999, 11 (04) : 199 - 211
  • [29] X-ray computed tomography for medical imaging
    Hiriyannaiah, HP
    [J]. IEEE SIGNAL PROCESSING MAGAZINE, 1997, 14 (02) : 42 - 59
  • [30] Microscopic x-ray luminescence computed tomography
    Zhang, Wei
    Zhu, Dianwen
    Zhang, Kun
    Li, Changqing
    [J]. MULTIMODAL BIOMEDICAL IMAGING X, 2015, 9316