Investigation of the Long-Term Performance of Waste Backfill Materials of High Thermal Conductivity in Vertical Ground Heat Exchangers

被引:0
|
作者
Wu, Ruichun [1 ]
Chen, Panpan [1 ]
Liu, Xinye [2 ]
Xu, Haiqiang [1 ]
Zhang, Guozhu [2 ]
Chen, Ankang [1 ]
机构
[1] Hongyuan Elect Power Design Inst Co Ltd, Taizhou 318000, Peoples R China
[2] Southeast Univ, Jiangsu Key Lab Urban Underground Engn & Environm, Nanjing 211196, Peoples R China
关键词
vertical ground heat exchangers; backfill materials of high thermal conductivity; waste material of fly ash; long-term performance; PHC ENERGY PILE; GROUTING MATERIALS; TEMPERATURE; FLOW; ENHANCEMENT;
D O I
10.3390/buildings14061699
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Backfill material used as a heat-transfer medium in boreholes of ground heat exchangers (GHEs) has a great influence on heat-transfer efficiency. Abandoned waste material causing environmental pollution has become a key issue around the world. To make full use of solid waste, backfill material made of waste fly ash in combination with graphite of high thermal conductivity was proposed. First, the thermal properties of cement/fly ash blended with different mass ratio of graphite were tested through laboratory tests. Then, a numerical model was established, in which the accuracy was validated based on a field test. Finally, an investigation of the long-term performance (over a period of 90 days) for four boreholes backfilled with natural sand, cement/fly ash, and cement/fly ash combined with different proportions of graphite was conducted through this numerical model, and the heat-transfer rates under constant inlet temperature in four boreholes decreased from 13.31, 44.97, 45.95, and 46.73 W/m to 14.18, 14.96, 15.66, and 16.19 W/m after the 90-day operation. Considering the influence of groundwater seepage, the horizontal groundwater flow had a positive impact, improving the long-term heat-transfer performance. The heat-transfer rates of four testing boreholes decreased from 44.46, 46.38, 47.22, and 47.68 W/m to 21.18, 21.93, 22.62, and 23.13 W/m. However, long-term groundwater seepage in a vertical direction caused a sharp decrease in the heat-transfer rate, and the values after 90 days were 10.44, 10.62, 10.78, and 10.81 W/m, which were the lowest of all the working conditions. The feasibility of using fly ash blended with graphite as backfill material was further validated through a comprehensive perspective, including indoor laboratory, field testing, and numerical simulation, which has rarely been conducted in previous research.
引用
收藏
页数:21
相关论文
共 50 条
  • [21] Fast segregation of thermal response functions in short-term for vertical ground heat exchangers
    Extremera-Jimenez, Alejandro J.
    Yousif, Charles
    Casanova-Pelaez, Pedro J.
    Cruz-Peragon, Fernando
    APPLIED THERMAL ENGINEERING, 2024, 246
  • [22] Thermal performance and ground temperature of vertical pile-foundation heat exchangers: A case study
    Gao, Jun
    Zhang, Xu
    Liu, Jun
    Li, Kui Shan
    Yang, Jie
    APPLIED THERMAL ENGINEERING, 2008, 28 (17-18) : 2295 - 2304
  • [24] Development of a Phase Change Backfill Material with High Heat Capacity and High Thermal Conductivity Used for Ground Source Heat Pumps
    Chen, Yixia
    Luo, Tingting
    Pei, Peng
    Ran, Yujin
    Tang, Long
    INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2023, 2023
  • [25] High performance materials for long-term usage
    Piwonka, TS
    MATERIALS TRANSACTIONS, 2002, 43 (03) : 376 - 378
  • [26] Numerical investigation on thermal performance of horizontal backfill coupled heat exchangers with different sizes and quantities in mine stopes
    Huan, Chao
    Yang, Zhengna
    Song, Mengjie
    Zhou, Shiqiang
    Hong, Sung Joo
    Thermal Science and Engineering Progress, 2025, 57
  • [27] Long-term monitoring and performance of ground source heat pumps
    Stafford, A.
    BUILDING RESEARCH AND INFORMATION, 2011, 39 (06): : 566 - 573
  • [28] Long-term energy and exergy analysis of heat pumps with different types of ground and air heat exchangers
    Habibi, Mohammad
    Hakkaki-Fard, Ali
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2019, 100 : 414 - 433
  • [29] Impact of grout thermal conductivity on the long-term efficiency ofthe ground-source heat pump systemTomislav
    Kurevija, Tomislav
    Macenic, Marija
    Borovic, Stasa
    SUSTAINABLE CITIES AND SOCIETY, 2017, 31 : 1 - 11
  • [30] Research on the long-term operation performance of deep borehole heat exchangers array: Thermal attenuation and maximum heat extraction capacity
    Deng, Jiewen
    Peng, Chenwei
    Su, Yangyang
    Qiang, Wenbo
    Wei, Qingpeng
    ENERGY AND BUILDINGS, 2023, 298